Kutai electronics ADVR-054 Operation Manual

Kutai electronics ADVR-054 Operation Manual

Universal hybrid analog-digital voltage regulator

Advertisement

ADVR-054
Universal Hybrid Analog-Digital
Voltage Regulator Operation Manual
Self Excited 5 Amp Analog / Digital Voltage Regulator
For shunt and auxiliary windings generators
With over-excitation and lost of sensing protection
Use with Kutai EP200 Paralleling Module for parallel operation
KUTAI ELECTRONICS INDUSTRY CO., LTD.
TEL : +886-7-8121771
FAX : +886-7-8121775
Website : www.kutai.com.tw
Headquarters : No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVR-054 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kutai electronics ADVR-054

  • Page 1 Self Excited 5 Amp Analog / Digital Voltage Regulator For shunt and auxiliary windings generators With over-excitation and lost of sensing protection Use with Kutai EP200 Paralleling Module for parallel operation KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw...
  • Page 2: Section 1 : Specification

    Soft Start Ramp Time 4.76 (L) x 3.19 (W) x 1.75 (H) inch 3 seconds +/- 10% Weight Typical System Response 270 g +/- 2% Less than 20 milliseconds 0.6 lb +/- 2% EMI Suppression Internal electromagnetic interference filtering ___________________________________________________________________________________________ ADVR-054...
  • Page 3: Section 2 : Appearance / Dimensions / Installation Drawing

    2. The voltage regulator may be installed at any suitable location on the generator set (dimensions are shown in Figure 1). It is recommended that unit is mounted vertically with the green resistors on the regulator upwards to achieve the best cooling effect. 3. All AC voltage sensing readings are average value only. ___________________________________________________________________________________________ ADVR-054...
  • Page 4: Section 3 : Dip Switch Settings, Led Indicators And Adjustments

    60 Hz system preset at 55 Hz, O/E Protection SW3 ON:Disable, OFF:Enable To change the setting, see the Adjustment Step 3. ADVR-054 C : Sensing Input and Power Input terminals EXT.VR Ext Potentiometer, 1K ohm 1W. Keep shorted when B:Power Input terminal not in use.
  • Page 5: Section 4 : Connection Diagrams

    SECTION 4 : CONNECTION DIAGRAMS Field Field 1000 Ohm 1000 Ohm EXT. VR EXT. VR ADVR-054 ADVR-054 Refer to Section 3 Refer to Section 3 Switch Switch setting. setting. Figure 3 170  260V sensing connection (Option 1) Figure 4 170  260V sensing connection (Option 2)