Kutai electronics ADVR-073 Operation Manual

Kutai electronics ADVR-073 Operation Manual

Universal hybrid analog-digital voltage regulator

Advertisement

Quick Links

ADVR-073
Universal Hybrid Analog-Digital
Voltage Regulator Operation Manual
Self Excited 7 Amp Analog / Digital Voltage Regulator
For shunt and auxiliary windings generators
With over-excitation and lost of sensing protection
KUTAI ELECTRONICS INDUSTRY CO., LTD.
TEL : +886-7-8121771
FAX : +886-7-8121775
Website : www.kutai.com.tw
Headquarters : No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVR-073 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kutai electronics ADVR-073

  • Page 1 Voltage Regulator Operation Manual Self Excited 7 Amp Analog / Digital Voltage Regulator For shunt and auxiliary windings generators With over-excitation and lost of sensing protection KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw...
  • Page 2: Section 1 : Summary

    SECTION 1 : SUMMARY The ADVR-073 is an advance (Hybrid Analog/Digital In addition, we added over excitation and loss of Voltage Regulator) design general-purpose sensing shutdown protections, with matching U/F, O/E isochronous stand alone applications. The ADVR-073 LED indicator lights. Consequently, this AVR prevents...
  • Page 3: Section 3 : Wiring

    Power Input Voltage Selection severe damage to the AVR or exciter. The If generator rated voltage is 220 Vac (Line to line ADVR-073 over excitation protection phase voltage), the power input B, C and sensing shutdown that cuts excitation at once.
  • Page 4: Section 7 : Startup Adjustment

    8.2.2 Restart generator and measure the residual voltage by AC Voltmeter, if it is still less than 5 Vac, repeat the previous process, after several times, the residual voltage still cannot be built, Kutai EB500 is strongly recommended, see Figure 1. ___________________________________________________________________________________________ ADVR-073...
  • Page 5: Section 9 : Trouble Shooting

    1000 OHM EXT. VR Unit : mm O/E Over Excitation protection U/F Frequency protection SW-1 Frequency Selection SW-2 Sensing Voltage Selection SW-3 Activate Over-Excitation Protection ADVR-073 SW-2 ON 170  260 Vac Figure 2 Outline Drawing Figure 3 ___________________________________________________________________________________________ ADVR-073...
  • Page 6 1000 OHM 1000 OHM 1000 OHM EXT. VR EXT. VR EXT. VR ADVR-073 ADVR-073 SW-2 ON 170  260 Vac SW-2 OFF 340  520 Vac Figure 4 Figure 5 Field SWITCH 20~200 OHM Aux. winding DIODE 1000 OHM Field BATT.

Table of Contents