Kutai electronics EA341 Operation Manual

Kutai electronics EA341 Operation Manual

Generator automatic voltage regulator

Advertisement

EA341
Generator Automatic Voltage Regulator
Operation Manual
Self Excited Automatic Voltage Regulator
Compatible with Newage MX341*
* All manufacturer names and numbers are used for reference purpose only
and do not imply that any part is the product of these manufacturer.
KUTAI ELECTRONICS INDUSTRY CO., LTD.
TEL : +886-7-8121771
FAX : +886-7-8121775
Website : www.kutai.com.tw
Headquarters : No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EA341 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kutai electronics EA341

  • Page 1 Compatible with Newage MX341* * All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer. KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw...
  • Page 2: Section 1 : Specification

    394 g +/- 2% SECTION 2 : GENERAL DESCRIPTION The AVR senses the voltage in the main EA341 is a two phase sensed Automatic Voltage generator winding and controls the power fed to Regulator and forms part of the excitation system the exciter stator and hence the main rotor to for a brush-less generator.
  • Page 3: Section 3 : Summary Of Avr Controls

    TRIM To optimize analogue input sensitivity Clockwise increases the gain or sensitivity To set the over excitation cut off level Clockwise increase the cut off level To set the frequency related voltage dip Clockwise increases the voltage dip ___________________________________________________________________________________________ EA341...
  • Page 4: Section 4 : Adjustment Of Avr Controls

    500 Vac. Failure to diagram according to the kw rating of the observe this could result in equipment damage. generator. The correct setting of the Stability adjustment can be found by running the generator at no load and slowly turning the ___________________________________________________________________________________________ EA341...
  • Page 5: Section 5 : Fitting And Operating

    3. Improper setting of under-frequency protection could cause the output voltage of the unit to drop or become unstable under with changes in load. Avoid making any changes to the U/F setting unless necessary. 4. Set the O/E potemtiometer at max. position when paralleling. ___________________________________________________________________________________________ EA341...
  • Page 6 2 2 1 TRIM DROOP VOLTS EA341 EXC. TRIP FREQUENCY SELECTION SELECTION UFRO STABILITY 3 2 1 C B A INDICATOR 3-1 4P/60HZ C-A < 90KW 3-2 4P/50HZ C-B 90-550KW 2-1 6P/50HZ B-A > 550KW...

Table of Contents