Kutai electronics ADVR-12 Operation Manual

Kutai electronics ADVR-12 Operation Manual

Universal hybrid analog-digital voltage regulator

Advertisement

Universal Hybrid Analog-Digital
Voltage Regulator Operation Manual
Self Excited Automatic Voltage Regulator
For use in Brushless SHUNT, PMG and Auxiliary Winding
Compatible with Basler* AVC63-12, AVC125-10, CATERPILLAR*
VR6, Kato* K65-12B & K125-10B, Leroy Somer* 202-8634 regulators
Use with KUTAI IVT-1260 / IVT-2460 add-on module can boost
* All manufacturer names and numbers are used for reference purpose only
and do not imply that any part is the product of these manufacturer.
KUTAI ELECTRONICS INDUSTRY CO., LTD.
TEL : +886-7-8121771
Headquarters : No.3, Ln. 201, Qianfu St., Qianzhen Dist., Kaohsiung City 80664, Taiwan
ADVR-12
generator motor starting capacity.
FAX : +886-7-8121775
Website : www.kutai.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVR-12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kutai electronics ADVR-12

  • Page 1 * All manufacturer names and numbers are used for reference purpose only and do not imply that any part is the product of these manufacturer. KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw...
  • Page 2: Section 1 : Specification

    3.0 Gs @ 100  2K Hz 4 seconds +/- 10% Vibration Typical System Response Dimensions Less than 20 milliseconds 214.0 (L) x 163.0 (W) x 45.7 (H) mm EMI Suppression Weight Internal electromagnetic interference filtering 1130 g +/- 2% ___________________________________________________________________________________________ ADVR-12...
  • Page 3: Section 2 : Outline / Size Reference

    4. Improper setting of under-frequency protection could cause the output voltage of the unit to drop or become unstable under with changes in load. Avoid making any changes to the U/F setting unless necessary. 5. Turn off O/E in AVR when paralleling. SECTION 3 : DIP SWITCH PROGRAMMING & ADJUSTMENTS Power Sensing Figure 2 ___________________________________________________________________________________________ ADVR-12...
  • Page 4: Section 4 : Connection Terminal

    Single or Three phase power input range is 3  10 V/Hz. Positive excitation output (+) Negative excitation output (-) Over Excitation LED (O/E) Indicator illuminates when the generator is in Over-Excitation protection. Set point 125 Vdc +/- 5% @ 220 Vac. ___________________________________________________________________________________________ ADVR-12...
  • Page 5: Section 5 : Wiring Connections

    FIELD Figure 5 Three Phase Sensing with power transformer Figure 6 PMG or Auxiliary Winding with power transformer (If sensing or power voltage differs from ADVR-12, add PT1 or PT2.) (If sensing voltage differs from ADVR-12, add PT1.) Droop ADVR-12...
  • Page 6 6. When using PT1 of capacity > 100VA, must pay attention that the voltage and capacity of transformer PT2 has adequate excitation output. ※ Use only replacement fuses specified in this user manual. ※ Appearance and specifications of products are subject to change for improvement without prior notice. ___________________________________________________________________________________________ ADVR-12...