Prior To Installation; Prior To Installation & Ownership - True TCGG-60-S-LD Installation Manual

Hide thumbs Also See for TCGG-60-S-LD:
Table of Contents

Advertisement

Installation

Prior to Installation

Ownership
To ensure that your unit works properly from the first day, it must
be installed properly. We highly recommend a trained refrigeration
mechanic and electrician install your TRUE equipment. The cost of
a professional installation is money well spent.
Before you start to install your TRUE unit, carefully inspect it for
freight damage. If damage is discovered, immediately file a claim
with the delivery freight carrier.
TRUE is not responsible for damage incurred during shipment.
Cabinet Specification
This appliance is rated for open food storage.
Cabinet Location
• For proper operation, ambient temperatures shall not be less
than 60°F (15.5°C) and no greater than 104°F (40°C).
• Appliance is not suitable for outdoor use.
• Appliance is not suitable for an area where a pressure washer or
hose may be used.
• Ensure the location will provide adequate clearances and
sufficient airflow for the cabinet.
• Ensure the power supply for the cabinet matches the cabinet
specification sheet or cabinet data plate and is within the
rated voltage (+/-5%). Also, that the amp rating of the circuit is
correct and that it is properly grounded.
• The cabinet should always be plugged into its own individual
dedicated electrical circuit. The use of adapter plugs and
extension cords is prohibited.
Notice to Customer
Loss or spoilage of products in your refrigerator/freezer
is not covered by warranty. In addition
to following recommended installation
procedures, you must run the refrigerator/
freezer for 24 hours prior to usage to verify
its proper operation.
CLEARANCES
TCGG
WARNING – Warranty is void if ventilation is insufficient.
Page 4 of 18
TOP
SIDES
0"
0"
TCGG
Wire Gauge Chart
115
Volts
AMPS
20
2
14
3
14
4
14
5
14
6
14
7
14
8
14
9
14
10
14
12
14
14
14
16
14
18
14
20
14
25
12
30
12
35
10
40
10
45
10
50
10
230
Volts
AMPS
20
5
14
6
14
7
14
8
14
9
14
10
14
12
14
14
14
16
14
18
14
20
14
25
14
30
14
35
14
40
14
50
12
60
12
70
10
BACK
80
10
Open
90
10
100
10
03/24/2021
Distance In Feet To Center of Load
30
40
50
60
70
80
90
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
14
14
12
12
14
14
14
14
12
12
12
14
14
14
12
12
12
10
14
14
12
12
12
10
10
14
14
12
12
10
10
10
14
12
12
10
10
10
8
14
12
10
10
10
8
8
12
12
10
10
8
8
8
12
10
10
8
8
8
8
12
10
10
8
8
8
6
10
10
8
8
6
6
6
10
8
8
6
6
6
6
10
8
6
6
6
5
5
8
8
6
6
5
5
4
8
6
6
6
5
4
4
8
6
6
5
4
4
3
Distance In Feet To Center of Load
30
40
50
60
70
80
90
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
14
14
12
12
14
14
14
14
12
12
12
14
14
14
12
12
12
10
14
14
12
12
12
10
10
14
14
12
10
10
10
10
14
12
12
10
10
10
10
12
12
10
10
10
8
8
12
10
10
10
8
8
8
12
10
10
8
8
8
6
10
10
8
6
6
6
6
10
8
6
6
6
6
6
10
8
6
6
6
5
5
8
8
6
6
5
5
4
8
6
6
5
5
4
4
8
6
6
5
4
4
3
truemfg.com
100
120
140
160
14
14
14
14
14
14
14
12
14
12
12
12
12
12
10
10
12
10
10
10
10
10
10
8
10
10
8
8
10
8
8
8
10
8
8
8
8
8
8
6
8
6
6
6
8
6
6
6
8
8
8
5
6
6
5
5
6
5
4
4
5
4
4
3
4
4
3
2
4
3
2
2
3
3
2
1
3
2
1
1
100
120
140
160
14
14
14
14
14
14
14
12
14
14
12
12
14
12
12
12
12
12
12
10
12
12
10
10
12
10
10
10
10
10
10
8
10
10
8
8
10
8
8
8
10
8
8
8
8
8
6
6
8
6
6
6
8
6
6
5
6
6
5
5
6
5
4
4
5
4
4
3
4
4
2
2
4
3
2
2
3
3
1
1
3
2
1
1
TEC_TM_122 | REV. A | EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tcgg-48-sTcgg-36-s-ldTcgg-72-ldTcgg-48-hc-ld

Table of Contents