Commissioning

7.4 Switching on the motor

7.4
Switching on the motor
Before switching on the motor, make sure that the frequency converter parameters have
been correctly assigned.
Use appropriate commissioning tools (e.g. "Drive ES" or "STARTER").
CAUTION
Operation noise or abnormal noises
The motor can be damaged by improper handling during transport, storage, or setup. If a
damaged motor is operated, this can damage the winding or bearings and could even
destroy the system.
If the motor is not running smoothly or is emitting abnormal noises, shut the motor down
and try to determine the cause of the fault as it runs down.
Note the maximum rotational speed
The maximum rotational speed n
maximum speed is specified on the rating plate.
If the speed n
fits, etc. To ensure that the motor does not run at excessive speeds, the controller must
configured accordingly or speed monitoring must be activated in the drive system.
56
CAUTION
is exceeded, this can damage the bearings, short-circuiting rings, press
max
is the highest permissible operating speed. The
max
Operating Instructions, 04/2009, 610.48000.22
Synchronous/induction motors 1PH813