UM0121 - USER MANUAL
3PH PMDC/AC or BLDC/AC (Trapezoidal Driven) Motor Advanced Settings
Clicking the "Advanced Settings..." button opens the "Advanced Settings" dialog box (see
3., page
7). This is where the advanced PMDC/AC motor type parameters are set.
There are 6 groups of settings that are specified by the user:
a. PWM (Pulse Width Modulation) Settings
–
Pulse Width Modulation (PWM) Frequency in kHz
Note: The only value available in the Reference Design Kit is the "12.5kHz."
–
PWM Minimum Off Time in microseconds (µs) to detect the BEMF
Note: The only values available in the Reference Design Kit are "2.5µs" and "5µs."
–
Complementary PWM Signal (Synchronous Rectification)
Note: This setting is disabled in the Reference Design Kit at this time.
b. Current Loop
–
Current Blanking Window - prevents erroneous sampling of the current after the PWM is turned
ON in milliseconds (ms)
–
Current Event Counter Filter - defines the number of counter events required to validate a current
limitation event
c. D and Z Sampling Parameters
–
Sampling Clock (ISCF) - sets the frequency of the sampling clock for D and Z events in kHz
–
Unused MCIx (Motor Control) Input - defines in which state the unused MCI input can be fixed,
either "Grounded" or "Hi-Z"
d. Zero Crossing
–
After D Blanking Window - set the blanking window after a D event in microseconds (µs)
–
Z Event Counter Filter - defines the number of counter events required to validate a Z event
–
Threshold Voltage - voltage set (in Volts) for Z detection
e. Demagnetization
–
After C Blanking Window - set the blanking window after a C event in microseconds (µs)
–
D Event Counter Filter - defines the number of counter events required to validate a D event
–
Demagnetize "All Hardware," "Alternate Hardware/Software," or "All Software"
Note: The only option available in the Reference Design GUI is the "Alternate Hardware/Software"
event.
Note: The Demagnetization Time option is not available in the Reference Design Kit at this time.
Note: The Force Duty Cycle During Demagnetization option is not available in the Reference
Design Kit at this time.
Note: The Duty Cycle option is not available in the Reference Design Kit at this time.
f.
Stop Condition
–
Free Wheeling - after Stop, the motor will continue to spin freely
Note: Only the Free Wheeling Stop Condition is available in the Reference Design Kit at this time.
–
DC Current Braking
Note: This option is not available in the Reference Design Kit at this time.
Note: The Brake Level setting is not available in the Reference Design Kit at this time.
Note: The Brake Time setting is not available in the Reference Design Kit at this time.
6/21
Figure
Need help?
Do you have a question about the ControlBD-7FMC2 and is the answer not in the manual?
Questions and answers