Download Print this page
Water I.D. PoolLAB 2.0 User Manual

Water I.D. PoolLAB 2.0 User Manual

Photometer
Hide thumbs Also See for PoolLAB 2.0:

Advertisement

Quick Links

Water-i.d.
water testing equipment
Photometer
Water Testing Equipment
M a d e
i n
G e r m a n y
®
®
User Manual
Gebrauchsanleitung
Manual de usuario
Manuel d'utilisation
Manuale dell'utente
Quick Guide starts on page 14 | Quick
Guide ab Seite 14 | Guía rápida a partir
de la página 14 | Guide rapide à partir de
la page 14 | Guida rapida da pagina 14
V5

Advertisement

loading

Summary of Contents for Water I.D. PoolLAB 2.0

  • Page 1 Water-i.d. ® ® water testing equipment Photometer User Manual Gebrauchsanleitung Manual de usuario Manuel d’utilisation Manuale dell’utente Quick Guide starts on page 14 | Quick Guide ab Seite 14 | Guía rápida a partir de la página 14 | Guide rapide à partir de la page 14 | Guida rapida da pagina 14 Water Testing Equipment M a d e...
  • Page 3 Content | Inhaltsverzeichnis | Contenido | Contenu | Contenuto Delivery Content | Inhalt der Lieferung | Contenido de la entrega Contenu de la livraison | Contenuto della consegna Batteries | Batterien | Baterías | Piles | Batterie Switch On | Einschalten | Encender | Mise en marche | Accensione Device Settings | Geräteeinstellungen | Configuración del dispositivo Réglages de l'appareil | Impostazioni del dispositivo Cloud | Nube | Nuvola...
  • Page 4 TEST – Instructions | Anleitungen | Instrucciones | Istruzioni Active Oxygen (MPS) 1–ACT Alkalinity M (CaCO ) 2–TA Aluminium (Al) 3–ALU Ammonia (NH ) 4–AMM Bromine (Br ) 5–BRO Calcium Hardness (CaCO ) 6–CH Chloramine (NH Cl/NHCl ) 7–CLA Chlorine (fCl /cCl /tCl ) 8–CL Chlorine HR (Cl ) 9–CLHR...
  • Page 5 Hardness Conversion | Härte Umrechnung | Conversión de la dureza | Conversion de la dureté | Conversione della durezza OR/UR Error Codes | Fehler-Codes | Códigos de error | Codes d'erreur | Codici di errore Changing The Cuvette | Küvette wechseln | Cambio de la cubeta | Changement de la Cuvette | Sostituzione della cuvetta Accessories (Reagents &...
  • Page 6 Delivery Content | Inhalt der Lieferung | Contenido de la entrega | Contenu de la livraison | Contenuto della consegna ® 1 x PoolLab 2.0 1 x Light shield 3 x AA Batteries 3 x Crushing | Stirring Rods (white, blue, red)
  • Page 7 Batteries | Batterien | Baterías | Piles | Batterie Change Wechseln Cambio Changer Cambiamento 3 x AA No rechargeable batteries! Keine aufladbaren Batterien! ¡No hay baterías recargables! Pas de piles rechargeables! Niente batterie ricaricabili!
  • Page 8 Switch On | Einschalten | Encender | Allumer | Accendere ® 00:02 ZERO TEST...
  • Page 9 1x – Starts Countdown/TEST when parallel measurement 1x – Starts Countdown/TEST when single measurement 2 sec – Opens Parameterlist 1x – Opens ZERO TEST Sampling Points 1x – Opens Main Menu 1x – Starts WiFi Connection/ Cloud Sync. ® 2x – Bluetooth ON/OFF...
  • Page 10 Device Settings Geräteeinstellungen Configuración del dispositivo Réglages de l'appareil Impostazioni del dispositivo ® ZERO TEST...
  • Page 11 ZERO ZERO TEST TEST Confirm Return ZERO TEST ZERO TEST...
  • Page 12 Synchronisierung eingerichtet ist (einzurichten über die LabCOM App ® ® während das PoolLab 2.0 per Bluetooth mit der App verbunden ist), wird hier das Cloud-Konto angezeigt, mit dem synchronisiert wird. ¡Puro menú informativo! Si la sincronización en la nube está configurada para el PoolLab®...
  • Page 13 Verbindung eingerichtet ist (einzurichten über die LabCOM App während ® ® das PoolLab 2.0 per Bluetooth mit der App verbunden ist), wird hier das WLAN-Netzwerk angezeigt, mit dem synchronisiert wird. ¡Puro menú informativo! Si está configurada una conexión WiFi para el PoolLab®...
  • Page 14 2.0 mit der LabCOM App automatisch berichtigt, können in der App aber ® auch manuell geändert und auf das PoolLab 2.0 übertragen werden. In diesem Menü können Sie zusätzlich zwischen dem 12h-Format (z.B. 02:00 PM) oder dem 24h-Format (z.B. 14:00) wählen.
  • Page 15 2.0 mit der LabCOM App automatisch berichtigt, können in der App aber ® auch manuell geändert und auf das PoolLab 2.0 übertragen werden. In diesem Menü können Sie zusätzlich zwischen der Anzeige 1 (MM/TT/JJJJ – Beispiel 09/27/2023) und der Anzeige 2 (TT/MM/JJJJ –...
  • Page 16 Device Settings | Geräteeinstellungen | Configuración del dispositivo | Réglages de l'appareil | Impostazioni del dispositivo pH | fCl | tCl | cCl | Br | ClO | O Some parameters (see listed above) can be measured on the PoolLab® 2.0 with both tablet reagents and liquid reagents.
  • Page 17 In the LabCOM® App you can create measurement sources (e.g. "Pool 1", "Pool 2") and then transfer them to the PoolLab® 2.0 with an existing Bluetooth® connection to the PoolLab 2.0. In this menu you can select the measurement source under which the following measurements are to be saved.
  • Page 18 Here you can set the brightness of the PoolLab® 2.0 display. The brighter the display is set, the higher the power consumption of the PoolLab® 2.0. ® Hier können Sie die Helligkeit des PoolLab 2.0 Displays einstellen. Je heller das Display eingestellt ist, desto höher ist der Stromverbrauch ®...
  • Page 20 Advices Hinweise Consejos Conseils Consigli...
  • Page 21 ONLY SINGLE The parameter to be measured may only be measured stand-alone (so NOT in parallel with other parameters). Der zu messende Parameter darf nur allein (also NICHT parallel mit anderen Parametern) gemessen werden. El parámetro a medir sólo puede medirse solo (es decir, NO en paralelo con otros parámetros).
  • Page 22 Kammer einen anderen zu verwenden. ® Para evitar la contaminación cruzada, su PoolLab 2.0 viene con 3 varillas agitadoras de diferentes colores. Se recomienda no utilizar la misma varilla agitadora (por ejemplo, sólo la blanca) para una medición paralela, sino una diferente para cada cámara.
  • Page 23 PHOTOMETER RAPID Always use PHOTOMETER grade tablets! Never use RAPID grade tablets! RAPID tablets lead to incorrect measurement results! Do not touch reagent tablets! Immer PHOTOMETER-Tabletten und nie RAPID–Tabletten verwenden! RAPID–Tabletten führen zu falschen Messergebnissen! Die Tabletten dürfen nicht berührt werden! ¡Usar siempre tabletas FOTÓMETRO y nunca usar tabletas RAPID! Las pastillas RAPID conducen a resultados de medición incorrectos.
  • Page 24 Advices | Hinweise | Consejos | Conseils | Consigli 1) The date of your PoolLab® 2.0 is preset when delivered, but may differ from your time zone. The date and time can be changed via the free LabCOM® app (Bluetooth® connection). If the battery change takes longer than 2 minutes or batteries are inserted incorrectly, the date will be deleted.
  • Page 25 1) La date de votre PoolLab® 2.0 est préréglée à la livraison, mais peut différer de votre fuseau horaire. La date et l'heure peuvent être modifiées via l'application gratuite LabCOM® (connexion Bluetooth®). Si le remplace- ment des piles dure plus de 2 minutes ou si les piles sont mal insérées, la date sera effacée.
  • Page 26 Advices | Hinweise | Consejos | Conseils | Consigli clean ! ZERO ZERO TEST Detergent waterproof (IP68) It is important to clean the device after each measurement to get rid of any reagent residues! Please ensure that the cuvette has been cleaned before each measurement (e.g.
  • Page 27 Do not leave the device in the sun! Lassen Sie das Gerät nicht in der Sonne liegen! ¡No deje el dispositivo al sol! Ne laissez pas l'appareil au soleil! Non lasciare il dispositivo al sole! ® The PoolLab is also suitable for saltwater pools/salt electrolysis pools! ®...
  • Page 28 SINGLE PARAMETER Quick Start Guide Kurzanleitung Guía De Inicio Rápido Guide De Démarrage Rapide Guida Rapida ® ® 00:02 ZERO ZERO TEST TEST...
  • Page 29 No Reagents! 10 ml ZERO ZERO TEST waterproof (IP68) 1 2 3 1 2 3 ZERO TEST -- -- -- ZERO ZERO TEST SAMP TEST MENU...
  • Page 30 SINGLE PARAMETER Quick Start Guide | Kurzanleitung Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida 19-NTRAT 20-OZON 21-PH 00:02 TEST -- -- ZERO TEST ZERO TEST 21-PH 22-PHMB 23-PPLR TEST ZERO TEST ZERO TEST Reagents for your test (refer to chapter in manual)
  • Page 31 Completely Dissolved TEST TEST ZERO TEST NO Residue ZERO TEST TEST 7.21 ZERO TEST...
  • Page 32 MULTIPLE PARAMETER Quick Start Guide Kurzanleitung Guía De Inicio Rápido Guide De Démarrage Rapide Guida Rapida ® ® 00:02 ZERO ZERO TEST TEST...
  • Page 33 No Reagents! 10 ml ZERO ZERO TEST waterproof (IP68) 1 2 3 1 2 3 ZERO TEST -- -- -- ZERO ZERO TEST SAMP TEST MENU...
  • Page 34 MULTIPLE PARAMETER Quick Start Guide | Kurzanleitung Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida 1-ACT TEST 2-TA 00:02 3-ALU ZERO TEST ZERO TEST 1-ACT TEST 2-TA 3-ALU 00:02 ZERO ZERO TEST TEST...
  • Page 35 1-ACT 1-ACT 2-TA 2-TA 3-ALU 3-ALU ZERO ZERO TEST TEST 1-ACT TEST 2-TA 3-ALU 00:02 ZERO TEST ZERO TEST...
  • Page 36 MULTIPLE PARAMETER Quick Start Guide | Kurzanleitung Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida 1-ACT 2-TA 3-ALU TEST ZERO TEST TEST Completely TEST Dissolved ZERO TEST ZERO TEST NO Residue Reagents for your test (Refer to chapter in manual)
  • Page 37 TEST TEST ZERO TEST ZERO TEST Starts Countdown Completely Dissolved ZERO TEST ZERO TEST NO Residue Reagents for your test (Refer to chapter in manual)
  • Page 38 MULTIPLE PARAMETER Quick Start Guide | Kurzanleitung Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida ZERO TEST ZERO TEST Starts Countdown ! Completely Dissolved ZERO TEST ZERO TEST NO Residue Reagents for your test (Refer to chapter in manual)
  • Page 39 ZERO TEST ZERO TEST Starts Countdown ! 7.21 8.50 0.12 PHMB PHMB ALU ZERO ZERO TEST TEST Starts Testing !
  • Page 41 MULTIPLE PARAMETER Quick Start Guide | Kurzanleitung Guía De Inicio Rápido | Guide De Démarrage Rapide | Guida Rapida As long you press the TEST button before the end of the recommended countdown, the countdown/clock will be displayed in green. If you need a little longer than the recommended time, the colour of the countdown changes to red.
  • Page 42 ZERO The ZERO step must only be carried out once after switching on and not necessarily before each following measurement. Der ZERO Schritt muss nur 1 x nach dem Einschalten und nicht zwingend vor jeder dann folgenden Messung durchgeführt werden. El paso a ZERO sólo debe realizarse una vez tras el encendido y no necesariamente antes de cada medición posterior.
  • Page 43 ZERO No Reagents! Keine Reagenzien! ¡No hay reactivos! ZERO TEST Pas de réactifs! Nessun reagente! 1 2 3 1 2 3 TEST ZERO ZERO TEST ZERO TEST...
  • Page 45 ZERO Only 1 time per test batch The "ZERO" step (page 42) is only necessary once after switching on. Make sure that the water to be measured does not (!) contain any tablet/reagent in the cuvette and that the light protection cover is in place. Please always perform ZERO with the pool water to be measured.
  • Page 46 30.0 Active Oxygen (MPS) Aktivsauerstoff (MPS) Oxígeno Activo (MPS) 1–ACT Oxygène Actif (MPS) 10.0 Ossigeno Attivo (MPS) 0.0 – 30.0 ppm (mg/l) MPS DPD N°4 Photometer* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST...
  • Page 47 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 1-ACT 19–PHMB 2-TA 20–PPLR 3-ALU 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 48 1 x DPD N°4 Photometer 1-ACT 2-TA 3-ALU TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 49 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 25.00...
  • Page 50 Alkalinity (M) Alkalität (M) Alcalinidad (M) 2–TA Alcalinité (M) Alcalinità (M) 0 – 200 ppm (mg/l) CaCO Alkalinity–M Photometer 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 51 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 1-ACT 19–PHMB 2-TA 20–PPLR 3-ALU 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 52 1 x Alkalinity-M Photometer 1-ACT 2-TA 3-ALU TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 53 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST ZERO 11–CU TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB mg/l 20–PPLR...
  • Page 54 0.30 Aluminium ONLY SINGLE (p. 21) Aluminium Aluminio 3–ALU Aluminium 0.15 Alluminio 0.00 – 0.30 ppm (mg/l) Al Aluminium N°1 Photometer* Aluminium N°2 Photometer* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 55 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 2-TA 19–PHMB 3-ALU 20–PPLR 4-AMM 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 56 1 x Aluminium N°1 Photometer 2-TA 3-ALU 4-AMM TEST ZERO ZERO TEST TEST USE FORCE! 1 x Aluminium N°2 Photometer Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 57 1–ACT 2–TA USE FORCE! 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL TEST 9–CLHR TEST NO Residue 10–CLO2 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB TEST 20–PPLR 0.10 21–PPHR mg/l (ppm) 22–POT 23–QUAT 24–SULF ZERO TEST 25–TH...
  • Page 58 1.20 Ammonia ONLY SINGLE (p. 21) Ammoniak Amonio 4–AMM Ammoniak 0.60 Ammonio 0.00 – 1.20 ppm (mg/l) NH Ammonia N°1 Powder Pillow* Ammonia N°2 Powder Pillow* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST...
  • Page 59 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 3-ALU 19–PHMB 4-AMM 20–PPLR 5-BRO 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 60 1 x Ammonia N°1 Photometer 3-ALU 4-AMM 5-BRO TEST ZERO ZERO TEST TEST 1 x Ammonia N°2 Photometer Completely Dissolved NO Residue TEST TEST ZERO TEST ZERO TEST...
  • Page 61 1–ACT 2–TA 3–ALU Completely 4–AMM Dissolved 5–BRO 6–CH NO Residue 7–CLA 8–CL TEST 9–CLHR TEST 10–CLO2 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB TEST 20–PPLR 0.40 mg/l 21–PPHR (ppm) 0.93N 1.12NH 22–POT 23–QUAT 24–SULF ZERO TEST 25–TH...
  • Page 62 18.00 9.00 Bromine Brom Bromo 5–BRO Brome 9.00 4.00 Bromo Liquid Mode: Tablet Mode: 0.00 – 18.00 ppm (mg/l) Br 0.00 – 9.00 ppm (mg/l) Br DPD N°1 Photometer Tablet DPD 1A + DPD 1B Liquid* Glycine* Glycine* 0.00 0.00 1...4 Page 42 10 ml...
  • Page 63 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 4-AMM 19–PHMB 5-BRO 20–PPLR 6-CH 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 64 4-AMM 5-BRO 6-CH ZERO TEST Only if your water sample does contain Chlorine next to Bromine (both disinfectants used), the following procedure "A" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Bromine present), please follow procedure "B". Nur wenn die Wasserprobe neben Brom auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „A"...
  • Page 65 With Chlorine | Mit Chlor | Con Cloro | Avec Du Chlore | Con il Cloro 1–ACT 2–TA USE FORCE! 1 x Glycine 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL 9–CLHR TEST TEST NO Residue 10–CLO2 11–CU ZERO TEST ZERO TEST 12–CYA...
  • Page 66 Without Chlorine | Ohne Chlor | Sin Cloro | Sans Chlore | Senza Cloro Tablet or Liquid? (p.16) USE FORCE! 1 x DPD N°1 Photometer 3 x DPD 1A + 3 x DPD 1B Completely Dissolved TEST NO Residue TEST ZERO TEST ZERO...
  • Page 67 1–ACT 2–TA If multiple parameters: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 7.00 mg/l 21–PPHR (ppm) 22–POT 23–QUAT 24–SULF...
  • Page 68 Calcium Hardness Kalziumhärte Dureza del calcio 6–CH Dureté du calcium Durezza del calcio 0 – 500 ppm (mg/l) CaCO Calcium Hardness N°1* Calcium Hardness N°2* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 69 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 5-BRO 19–PHMB 6-CH 20–PPLR 7-CLA 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 70 POL20CaH1* POL20CaH2* *Shake Before Use! 5-BRO 6-CH 7-CLA TEST ZERO TEST ZERO TEST TEST TEST ZERO TEST ZERO TEST...
  • Page 71 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST ZERO 11–CU TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB mg/l 20–PPLR...
  • Page 72 8.00 Chloramine Chloramin Cloramina 7–CLA Chloramine 4.00 Cloramina 0.00 – 8.00 ppm (mg/l) fCl DPD N°1 Photometer DPD N°2 Photometer* DPD N°3 Photometer 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 73 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 6-CH 19–PHMB 7-CLA 20–PPLR 8-CL 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 74 6-CH 7-CLA 8-CL TEST ZERO TEST ZERO TEST Few drops 1 x DPD N°1 Photometer TEST ZERO TEST...
  • Page 75 1–ACT 2–TA USE FORCE! 10 ml 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL 9–CLHR TEST TEST NO Residue 10–CLO2 11–CU ZERO ZERO TEST TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT TEST TEST 23–QUAT 24–SULF ZERO TEST ZERO...
  • Page 76 If multiple parameters: If single parameter: See page 32 TEST TEST Param 2 Param 3 ZERO TEST ZERO TEST ... p. 32 9 17 Mono-Chloramine 4.00 mg/l (ppm) ppm = mg/l Free Chlorine...
  • Page 77 1–ACT 2–TA 1 x DPD N°2 Photometer 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 9 21 USE FORCE! 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR Completely Dissolved 21–PPHR 22–POT 23–QUAT NO Residue 24–SULF ZERO TEST...
  • Page 78 If multiple parameters: If single parameter: See page 32 4.00 TEST mg/l (ppm) Param 2 Param 3 ZERO TEST ZERO TEST ... p. 32 Di-Chloramine 4.00 mg/l (ppm) NH Cl ppm = mg/l Mono-Chloramine...
  • Page 79 1–ACT 2–TA 1 x DPD N°3 Photometer 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL TEST 9–CLHR TEST 10–CLO2 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON USE FORCE! 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR Completely Dissolved 21–PPHR 22–POT TEST TEST 23–QUAT NO Residue 24–SULF ZERO...
  • Page 80 If multiple parameters: See page 32 4.00 TEST mg/l (ppm) NH Cl Param 2 Param 3 ZERO TEST ZERO TEST ... p. 32 4.00 mg/l (ppm) NHCl ppm = mg/l Di-Chloramine...
  • Page 81 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 82 8.00 4.00 Chlorine Chlor Cloro 8–CL Chlore 4.00 2.00 Cloro Liquid Mode: Tablet Mode: 0.00 – 6.00 ppm (mg/l) fCl 0.00 – 4.00 ppm (mg/l) fCl DPD N°1 Photometer DPD 1A* + DPD 1B* + DPD N°3 Photometer DPD 3C* Liquid 0.00 0.00 *not part of standard equipment...
  • Page 83 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 7-CLA 19–PHMB 8-CL 20–PPLR 9-CLHR 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 84 Tablet or Liquid? (p.16) 1 x DPD N°1 Photometer 3 x DPD 1A + 3 x DPD 1B 7-CLA 8-CL 9-CLHR TEST ZERO TEST ZERO TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 85 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 9 12 16–NTRA Total Chlorine 17–OZON 18–PH...
  • Page 86 Tablet or Liquid? (p.16) USE FORCE! 1 x DPD N°3 Photometer 3 x DPD 3C Completely Dissolved TEST NO Residue TEST ZERO TEST ZERO TEST 9 16 1.27 mg/l (ppm) TEST ZERO TEST ZERO TEST...
  • Page 87 1–ACT 2–TA If multiple parameters: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 1.27 mg/l 21–PPHR (ppm) 22–POT 23–QUAT 24–SULF...
  • Page 88 Chlorine (HR) Chlor ( HR ) Cloro ( HR ) 9–CLHR Chlore ( HR ) Cloro ( HR ) 5 – 200 ppm (mg/l) Cl Chlorine HR (KI)* Acidifying GP Powder Pillow* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO...
  • Page 89 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 8-CL 19–PHMB 9-CLHR 20–PPLR 10-CLO2 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 90 1 x Chlorine HR (KI) Photometer 8-CL 9-CLHR 10-CLO2 TEST ZERO ZERO TEST TEST USE FORCE! 1 x Acidifying GP Completely Dissolved TEST TEST NO Residue PPLR ZERO TEST ZERO TEST...
  • Page 91 1–ACT 2–TA If single parameter: 3–ALU 4–AMM Completely Dissolved 5–BRO 6–CH TEST 7–CLA NO Residue 8–CL CLHR 9–CLHR TEST 10–CLO2 PPLR 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA If multiple parameters: See page 32 17–OZON 18–PH 19–PHMB 20–PPLR TEST 21–PPHR...
  • Page 92 mg/l (ppm) CLHR ppm = mg/l...
  • Page 93 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 94 15.00 7.50 Chlorine Dioxide Chlordioxid Dióxido de cloro 10–CLO2 Dioxyde de chlore 8.50 3.00 Biossido di cloro Liquid Mode: Tablet Mode: 0.00 – 15.00 ppm (mg/l) ClO 0.00 – 7.50 ppm (mg/l) ClO DPD N°1 Photometer DPD 1A* + DPD 1B* Liquid Glycine* Glycine* 0.00...
  • Page 95 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 9-CLHR 19–PHMB 10-CLO2 20–PPLR 11-CU 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 96 9-CLHR 10-CLO2 11-CU ZERO TEST Only if your water sample does contain Chlorine next to Chlorine Dioxide (both disinfectants used), the following procedure "A" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Chlorine Dioxide present), please follow procedure "B". Nur wenn die Wasserprobe neben Chlordioxid auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „A"...
  • Page 97 With Chlorine | Mit Chlor | Con Cloro | Avec Du Chlore | Con il Cloro 1–ACT 2–TA USE FORCE! 1 x Glycine 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL 9–CLHR TEST TEST NO Residue 10–CLO2 CLO2 CLO2 11–CU ZERO TEST ZERO...
  • Page 98 Without Chlorine | Ohne Chlor | Sin Cloro | Sans Chlore | Senza Cloro Tablet or Liquid? (p.16) USE FORCE! 1 x DPD N°1 Photometer 3 x DPD 1A + 3 x DPD 1B Completely Dissolved TEST NO Residue TEST CLO2 CLO2 ZERO...
  • Page 99 1–ACT 2–TA If multiple parameters: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL CLO2 Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 8.00 mg/l 21–PPHR (ppm) 22–POT CLO2...
  • Page 100 5.00 Copper Kupfer Cobre 11–CU Cuivre 2.50 Rame 0.00 – 5.00 ppm (mg/l) fCu/tCu Copper N°1 Photometer* Copper N°2 Photometer* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 101 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 10-CLO2 19–PHMB 11-CU 20–PPLR 12-CYA 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 102 1 x Copper N°1 Photometer 10-CLO2 11-CU 12-CYA TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 103 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST ZERO 11–CU TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON Total Copper 16–NTRA 17–OZON 18–PH 19–PHMB...
  • Page 104 USE FORCE! 1 x Copper N°2 Photometer Completely Dissolved TEST TEST NO Residue ZERO ZERO TEST TEST 9 16 3.54 mg/l (ppm) TEST ZERO TEST ZERO TEST...
  • Page 105 1–ACT 2–TA If multiple parameters: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU 12–CYA ... p. 32 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 4.82 mg/l 21–PPHR (ppm) 22–POT 23–QUAT 24–SULF...
  • Page 106 Cyanuric acid Cyanursäure Ácido cianúrico 12–CYA Acide cyanurique Acido cianurico 0 – 160 ppm (mg/l) CYA CYA Test Photometer 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 107 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 11-CU 19–PHMB 12-CYA 20–PPLR 13-HYDL 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 108 1 x CYA–Test Photometer 11-CU 12-CYA 13-HYDL TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 109 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR mg/l...
  • Page 110 Hydrogen Peroxide (LR) 2.90 Wasserstoffperoxid (LR) Peróxido de hidrógeno (LR) 13–HYDL Peroxyde d'hydrogène (LR) Perossido di idrogeno (LR) 1.45 0.00 – 2.90 ppm (mg/l) H O Hydr. Peroxide LR Photometer* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO...
  • Page 111 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 12-CYA 19–PHMB 13-HYDL 20–PPLR 14-HYDH 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 112 1 x Hydr. Peroxide LR Photometer 12-CYA 13-HYDL 14-HYDH TEST ZERO TEST ZERO TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 113 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL HYDL Param 2 Param 3 HYDL 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB...
  • Page 114 Hydrogen Peroxide (HR) Wasserstoffperoxid (HR) Peróxido de hidrógeno (HR) 14–HYDH Peroxyde d'hydrogène (HR) Perossido di idrogeno (HR) 0 – 200 ppm (mg/l) H O Hydr. Peroxide HR Photometer* Acidifying PT* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO...
  • Page 115 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 13-HYDL 19–PHMB 14-HYDH 20–PPLR 15-IRON 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 116 1 x Acidifying PT 13-HYDL 14-HYDH 15-IRON TEST HYDH ZERO TEST ZERO TEST USE FORCE! 1 x Hydr. Peroxide HR Photometer Completely Dissolved TEST TEST NO Residue HYDH HYDH ZERO ZERO TEST TEST...
  • Page 117 1–ACT 2–TA USE FORCE! 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL TEST 9–CLHR TEST NO Residue 10–CLO2 HYDH HYDH 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA If multiple parameters: If single parameter: See page 32 17–OZON 18–PH 19–PHMB TEST...
  • Page 118 mg/l (ppm) HYDH ppm = mg/l...
  • Page 119 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 120 Iron (LR) 1.00 ONLY SINGLE (p. 21) Eisen (LR) Hierro (LR) 15–IRON Fer (LR) Ferro (LR) 0.50 0.00 – 1.00 ppm (mg/l) Fe /Fe Iron LR Photometer* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO...
  • Page 121 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 14-HYDH 19–PHMB 15-IRON 20–PPLR 16-NTRA 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 122 1 x Iron LR Photometer 14-HYDH 15-IRON 16-NTRA TEST IRON ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST IRON NO Residue IRON ZERO TEST ZERO TEST...
  • Page 123 1–ACT 2–TA 3–ALU 4–AMM 5–BRO TEST 6–CH 0.50 7–CLA mg/l (ppm) IRON Fe²⁺/Fe³⁺ 8–CL 9–CLHR IRON 10–CLO2 ZERO TEST 11–CU 12–CYA ppm = mg/l 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 124 Nitrate ONLY SINGLE (p. 21) Nitrat Nitrato 16–NTRA Nitrate Nitrato 1 – 100 ppm (mg/l) NO Nitrate N°1 Photometer Powder Pillow* Nitrate N°2 Photometer Powder Pillow* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST...
  • Page 125 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 0 ml 17–OZON 18–PH 1 2 3 19–PHMB 20–PPLR 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST SAMP...
  • Page 126 15-IRON 15-IRON 16-NTRA 16-NTRA 17-OZON 17-OZON ZERO ZERO TEST TEST 1 x Nirate N°1 Photometer 20 ml sample water...
  • Page 127 1–ACT 2–TA 1 x Nirate N°2 3–ALU Photometer 4–AMM 00:15 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 9 13 16–NTRA 17–OZON 18–PH 10 ml 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 10:00 min 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 128 10 ml TEST NTRA TEST NTRA ZERO TEST ZERO TEST TEST NTRA ZERO TEST...
  • Page 129 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA mg/l (ppm) NO₃⁻ 8–CL 9–CLHR NTRA 10–CLO2 11–CU 12–CYA ppm = mg/l 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 130 Ozone 5.40 2.70 Ozon Ozono 17–OZON Ozone Ozono 2.50 1.30 Liquid Mode: Tablet Mode: 0.00 – 5.40 ppm (mg/l) O 0.00 – 2.70 ppm (mg/l) O DPD N°1 Photometer DPD 1A* + DPD 1B* + DPD N°3 Photometer DPD 3C* Liquid Glycine* Glycine* 0.00...
  • Page 131 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 16-NTRA 19–PHMB 17-OZON 20–PPLR 18-PH 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 132 16-NTRA 17-OZON 18-PH ZERO TEST Only if your water sample does contain Ozone next to Chlorine (both disinfectants used), the following procedure "B" needs to be followed and Glycine* reagent needs to be used. Otherwise (only Ozone present), please follow procedure "A". Nur wenn die Wasserprobe neben Ozon auch Chlor enthält (beide Desinfektionsmittel wurden benutzt), muss das Verfahren „B"...
  • Page 133 Without Chlorine | Ohne Chlor | Sin Cloro | Sans Chlore | Senza Cloro 1–ACT Tablet or Liquid? (p.16) 2–TA USE FORCE! 1 x DPD N°1 Photometer + 3–ALU 1 x DPD N°3 Photometer 4–AMM 3 x DPD 1A + 3 x DPD 1B + 5–BRO 3 x DPD 3C Liquid 6–CH...
  • Page 134 If multiple parameters: See page 32 TEST OZON Param 2 Param 3 ZERO TEST ... p. 32 3.20 mg/l (ppm) OZON ppm = mg/l...
  • Page 135 With Chlorine | Mit Chlor | Con Cloro | Avec Du Chlore | Con il Cloro 1–ACT Tablet or Liquid? (p.16) 2–TA USE FORCE! 1 x DPD N°1 Photometer + 3–ALU 1 x DPD N°3 Photometer 4–AMM 3 x DPD 1A + 3 x DPD 1B + 5–BRO 3 x DPD 3C Liquid 6–CH...
  • Page 136 With Chlorine | Mit Chlor | Con Cloro | Avec Du Chlore | Con il Cloro If multiple parameters: See page 32 TEST OZON Param 2 Param 3 TEST CLO2 ZERO TEST ZERO TEST ... p. 32 0 ml 10 ml waterproof (IP68)
  • Page 137 1–ACT 2–TA USE FORCE! 3–ALU 1 x Glycine 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL 9–CLHR STEP 2 STEP 2 NO Residue 10–CLO2 11–CU ZERO ZERO TEST TEST 12–CYA 13–HYDL 14–HYDH 15–IRON Tablet or Liquid? (p.16) 16–NTRA USE FORCE! 1 x DPD N°1 Photometer + 17–OZON 1 x DPD N°3 Photometer 18–PH...
  • Page 138 If single parameter: TEST TEST OZON CLO2 ZERO TEST ZERO TEST If multiple parameters: See page 32 TEST OZON Param 2 Param 3 ZERO TEST ... p. 32...
  • Page 139 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 3.20 7–CLA mg/l (ppm) 8–CL 9–CLHR OZON 10–CLO2 11–CU 12–CYA 13–HYDL ppm = mg/l 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 140 8.40 8.40 18–PH 7.30 7.30 Liquid Mode: Tablet Mode: 6.50 – 8.40 ppm (mg/l) pH 6.50 – 8.40 ppm (mg/l) pH Phenol Red Photometer Phenol Red Liquid* 6.50 6.50 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO...
  • Page 141 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 17-OZON 19–PHMB 18-PH 20–PPLR 19-PHMB 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 142 Tablet or Liquid? (p.16) 1 x Phenol Red Photometer 6 x Phenol Red 17-OZON 18-PH 19-PHMB TEST ZERO TEST ZERO TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 143 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 7.20...
  • Page 144 The Total Alkalinity value has to be minimum 50 mg/l to obtain a correct pH value. Der Alkalinitätwert muss mindestens 50 mg/l betragen, um eine korrekte pH Messung durchzuführen. El valor de alcalinidad debe ser superior a 50 mg/l para obtener un pH correcto.
  • Page 145 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 146 PHMB 19–PHMB 5 – 60 ppm (mg/l) PHMB PHMB Photometer* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 147 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 18-PH 19–PHMB 19-PHMB 20–PPLR 20-PPLR 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 148 1 x PHMB Photometer 18-PH 19-PHMB 20-PPLR TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 149 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL PHMB Param 2 Param 3 PHMB 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB...
  • Page 150 It is imperative that you clean the objects used for the measure-ment and come into contact with the sample water containing the reagent (cuvette, lid, stirring rod) thoroughly with a brush, water and then with distilled water, otherwise the measuring equipment may turn blue over time. Alkalinity values (M) <>...
  • Page 151 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 152 Phosphate (LR) 4.00 ONLY SINGLE (p. 21) Phosphat (LR) Fosfato (LR) 20–PPLR Phosphate (LR) Fosfato (LR) 2.00 0.00 – 4.00 ppm (mg/l) PO Phosphate LR N°1 Powder Pillow Phosphate LR N°2 Photometer* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO...
  • Page 153 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 19-PHMB 19–PHMB 20-PPLR 20–PPLR 21-PPHR 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 154 1 x Phosphate LR N°1 Photometer 19-PHMB 20-PPLR 21-PPHR TEST PPLR ZERO ZERO TEST TEST 1 x Phosphate LR N°2 Photometer Completely Dissolved NO Residue TEST TEST PPLR PPLR ZERO TEST ZERO TEST...
  • Page 155 1–ACT 2–TA USE FORCE! 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL TEST 9–CLHR TEST NO Residue 10–CLO2 PPLR PPLR 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB TEST 20–PPLR 21–PPHR 3.00 mg/l (ppm) 22–POT PPLR PO₄³⁻...
  • Page 156 Phosphate (HR) ONLY SINGLE (p. 21) Phosphat (HR) Fosfato (HR) 21–PPHR Phosphate (HR) Fosfato (HR) 0 – 80 ppm (mg/l) PO Phosphate HR N°1 Photometer Powder Pillow* Phosphate HR N°2 Photometer* *not part of standard equipment 1...10 Page 42 clean ZERO ZERO ZERO...
  • Page 157 1–ACT 2–TA 3–ALU 4–AMM 25 mm (GF/C)-Filter 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 14 ml 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 158 10 ml 10 ml ZERO 4 ml ZERO TEST 1 2 3 ZERO ZERO ZERO ZERO TEST TEST...
  • Page 159 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 20-PPLR 6–CH 21-PPHR 22-POT 7–CLA 8–CL 00:02 TEST 9–CLHR 10–CLO2 ZERO ZERO TEST SAMP TEST 11–CU MENU 12–CYA 13–HYDL 14–HYDH 15–IRON CHAMBER 2! 9 13 16–NTRA 1 x Phosphate HR 17–OZON N°1 Photometer 18–PH 20-PPLR 19–PHMB...
  • Page 160 CHAMBER 2! 1 x Phosphate HR N°2 Photometer Completely Dissolved NO Residue TEST TEST PPHR PPHR ZERO TEST ZERO TEST 9 17 USE FORCE! Completely Dissolved TEST TEST PPHR PPHR NO Residue ZERO TEST ZERO TEST...
  • Page 161 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL PPHR Param 2 Param 3 PPHR 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 9 20 16–NTRA 17–OZON 18–PH...
  • Page 162 Potassium 12.0 ONLY SINGLE (p. 21) Kalium Potasio 22–POT Potassium Potassio 0.7 – 12.0 ppm (mg/l) K Potassium Photometer* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 163 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 21-PPHR 19–PHMB 22-POT 20–PPLR 23-QUAT 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 164 CHAMBER 2! 1 x Potassium Photometer 21-PPHR 22-POT 23-QUAT TEST ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST NO Residue ZERO TEST ZERO TEST...
  • Page 165 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR mg/l...
  • Page 166 23–QUAT QUAT 25 – 150 ppm (mg/l) QAC Acidifying GP Powder Pillow* QAC HR Photometer* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 167 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 22-POT 19–PHMB 23-QUAT 20–PPLR 24-SULF 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 168 1 x Acidifying GP 22-POT 23-QUAT 24-SULF TEST QUAT ZERO TEST ZERO TEST 1 x QAC HR Photometer Completely Dissolved NO Residue TEST TEST QUAT QUAT ZERO ZERO TEST TEST...
  • Page 169: Zero Test

    1–ACT 2–TA USE FORCE! 3–ALU 4–AMM 5–BRO 6–CH Completely 7–CLA Dissolved 8–CL TEST 9–CLHR TEST NO Residue 10–CLO2 QUAT QUAT 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA If multiple parameters: If single parameter: See page 32 17–OZON 18–PH 19–PHMB TEST...
  • Page 170 mg/l (ppm) QUAT ppm = mg/l...
  • Page 171 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR 10–CLO2 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT 23–QUAT 24–SULF 25–TH 26–UREA 27–ZINC...
  • Page 172: 24-Sulf

    Sulphate ONLY SINGLE (p. 21) Sulfat Sulfato 24–SULF Sulfate Solfato 5 – 100 ppm (mg/l) SO Sulphate Photometer Powder Pillow* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 173 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 23-QUAT 19–PHMB 24-SULF 20–PPLR 25-TH 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 174 1 x Sulphate Photometer 23-QUAT 24-SULF 25-TH TEST SULF ZERO ZERO TEST TEST Completely Dissolved NO Residue TEST TEST SULF SULF ZERO TEST ZERO TEST...
  • Page 175 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL SULF Param 2 Param 3 SULF 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB...
  • Page 176: 25-Th

    Total Hardness Gesamthärte Dureza Total 25–TH Dureté Totale Durezza Totale 0 – 500 ppm (mg/l) CaCO Total Hardness N°1* Total Hardness N°2* *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO ZERO ZERO TEST TEST waterproof (IP68)
  • Page 177 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 24-SULF 19–PHMB 25-TH 20–PPLR 26-UREA 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 178 POL20TH1* POL20TH2* *Shake Before Use! 24-SULF 25-TH 26-UREA TEST ZERO TEST ZERO TEST TEST TEST ZERO TEST ZERO TEST...
  • Page 179 1–ACT 2–TA If multiple parameters: If single parameter: See page 32 3–ALU 4–AMM 5–BRO 6–CH TEST TEST 7–CLA 8–CL Param 2 Param 3 9–CLHR 10–CLO2 ZERO TEST ZERO 11–CU TEST ... p. 32 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB mg/l 20–PPLR...
  • Page 180: 26-Urea

    Urea 2.50 Harnstoff ONLY SINGLE (p. 21) Urea Urée 26–UREA 1.20 0.10 – 2.50 ppm (mg/l) (NH ) CO Dechlor* PL Urea N°1* PL Urea N°2* Ammonia N°1 Photometer Powder Pillow* 0.10 Ammonia N° 2 Photometer Powder Pillow* *not part of standard equipment 1...4 Page 42 10 ml...
  • Page 181 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 25-TH 19–PHMB 26-UREA 20–PPLR 27-ZINC 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO TEST...
  • Page 182 PL30Urea1* *Shake Before Use! 25-TH 26-UREA 27-ZINC TEST UREA ZERO TEST ZERO TEST PL30Urea2* *Shake Before Use! TEST TEST UREA UREA ZERO TEST ZERO TEST...
  • Page 183 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL TEST 9–CLHR TEST UREA 10–CLO2 UREA 11–CU ZERO TEST ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 1 x Ammonia N°1 Photometer 17–OZON 18–PH 19–PHMB 20–PPLR 21–PPHR 22–POT TEST 23–QUAT 4:30 min UREA 24–SULF ZERO 25–TH...
  • Page 184 1 x Ammonia N°2 Photometer Completely Dissolved NO Residue TEST TEST UREA UREA ZERO TEST ZERO TEST 9 17 Completely Dissolved NO Residue TEST TEST UREA UREA ZERO TEST ZERO TEST...
  • Page 185 1–ACT 2–TA 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL UREA 9–CLHR 10–CLO2 11–CU ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 19–PHMB 0.70 20–PPLR mg/l (ppm) (NH ) CO 21–PPHR 22–POT UREA 23–QUAT 24–SULF 25–TH 26–UREA ppm = mg/l 27–ZINC...
  • Page 186 Zinc (with chlorine) 1.00 Zink (mit Chlor) Zinc (con cloro) 27–ZINC Zinc (avec chlore) Zinco (con cloro) 0.50 0.00 – 1.00 ppm (mg/l) Zn Dechlor* Copper/Zinc LR Photometer* EDTA* 0.00 *not part of standard equipment 1...4 Page 42 10 ml clean ZERO ZERO...
  • Page 187 1–ACT 2–TA 3–ALU 4–AMM 1 2 3 5–BRO 6–CH 7–CLA 8–CL ZERO ZERO 9–CLHR 10–CLO2 ZERO TEST ZERO TEST 11–CU 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA 17–OZON 18–PH 1 2 3 25-TH 19–PHMB 26 UREA 20–PPLR 27-ZINC 21–PPHR 22–POT 00:02 TEST 23–QUAT 24–SULF ZERO...
  • Page 188 1 x Dechlor 25-TH 26 UREA 27-ZINC TEST ZINC ZERO ZERO TEST TEST USE FORCE! Completely Dissolved TEST TEST ZINC NO Residue ZINC ZERO TEST ZERO TEST...
  • Page 189 1–ACT 2–TA 1 x Copper/Zinc LR 3–ALU 4–AMM 5–BRO 6–CH 7–CLA 8–CL 9–CLHR TEST 00:15 min ZINC 10–CLO2 11–CU ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON USE FORCE! 16–NTRA 17–OZON 18–PH 19–PHMB 20–PPLR Completely 21–PPHR Dissolved 22–POT TEST TEST 23–QUAT ZINC NO Residue ZINC 24–SULF...
  • Page 190 TEST ZINC 01:00 min ZERO TEST 9 17 USE FORCE! 1 x EDTA Completely Dissolved TEST TEST ZINC NO Residue ZERO TEST ZERO TEST...
  • Page 191 1–ACT 2–TA If single parameter: 3–ALU 4–AMM 5–BRO 6–CH TEST 7–CLA 8–CL ZINC TEST 9–CLHR 10–CLO2 ZERO TEST 11–CU ZERO TEST 12–CYA 13–HYDL 14–HYDH 15–IRON 16–NTRA If multiple parameters: See page 32 17–OZON 18–PH 19–PHMB 20–PPLR TEST 21–PPHR ZINC Param 2 Param 3 22–POT 0.20...
  • Page 193 Hardness Conversion | Härte-Umrechnung | Conversión De Dureza | Conversion De Dureté | Conversione Di Durezza CaCO °dH °e °f mval S 4,3 mg/l mmol/l (KH) (CH) (DC) 1 mg/l CaCO 0.01 0.056 0.07 0.02 1 mmol/l K 10.0 S 4,3...
  • Page 194 OR/UR OR = Overrange / UR = Underrange. Test result is outside the range of the method. OR results can be brought into measurement range by dilution. Use syringe to take only 5ml (or 1ml) sample water plus 5ml (9ml) distilled water. Test again and multiply results times 2 (times 10).
  • Page 195 Error Codes | Fehlercodes | Códigos De Error | Codes D'Erreur | Codici Di Errore Change batteries Batterien wechseln BAT!: Cambiar las pilas Changer les piles Cambiare le batterie (Too bright) Possibly light protection cover forgotten during measurement (Zu hell) Möglicherweise Lichtschutzdeckel während der Messung vergessen (Demasiado brillante) Posiblemente la cubierta de protección de la luz se olvidó...
  • Page 196 Changing The Cuvette Küvettenwechsel | Cambiar La Cubeta | Changer La Cuvette | Cambiando La Cuvetta Dry! 1 2 3 ZERO ZERO TEST TEST ZERO TEST ZERO TEST...
  • Page 197 Changing The Cuvette Küvettenwechsel | Cambiar La Cubeta | Changer La Cuvette | Cambiando La Cuvetta ZERO TEST ZERO TEST ZERO TEST No finger- prints!
  • Page 198 1 2 3 ZERO TEST ZERO TEST...
  • Page 200 Accessories | Zubehör | Accesorios | Accessoires | Accessori Reagents | Reagenzien | Reactivos | Réactifs | Reagenti POL-Ref Mix-Refill Pack with 70 tablets (20 each of DPD 1, Phenol Red, 10 each of Alka-M, CYA-Test and DPD 3) TbsPD450 50 tablets DPD N°4 Photometer TbsPTA50 50 tablets Alka-M Photometer...
  • Page 201 PoolLab 2.0 Replacement cuvette POL2Sp-refkit Check-Standard kit (3 x POL2Sp-kv) with check standards for ZERO/Chlorine LR/ Chlorine HR/pH/TA/CYA/Total Hardness ® POL2Sp-ls Light shield for PoolLab 2.0 ® POL2Sp-cuvhold Cuvette holder for PoolLab 2.0 POLSp-str White 10.5 cm plastic stirring rod POL2Sp-strB Blue 10.5 cm plastic stirring rod...
  • Page 202 WiFi connection, the cloud, the date/time and the measurement sources. ® ® ® Verbinden Sie das PoolLab 2.0 über Bluetooth mit der LabCOM App, um die WLAN-Verbindung, die Cloud, das Datum/Uhrzeit und die Messquellen einzustellen. Conecte el PoolLab® 2.0 mediante Bluetooth® a la app LabCOM® para configurar la conexión WiFi, la nube, la fecha/hora y las fuentes de medición.
  • Page 203 Technical Data | Technische Daten | Datos Técnicos | Données Techniques | Dati Tecnici https://poollab.org MSDS https://msds.water-id.com Cloud https://labcom.cloud Developed in Germany | Produced in PRC LED: 435 nm (only chamber 2) | 530 nm | 570 nm | 620 nm 3 x AA (1.5 V, LR03) Do not use rechargeable batteries! 3 00 sec.
  • Page 204 Tolerances | Toleranzen | Tolerancias | Tolérances | Tolleranze Active Oxygen (MPS) | Aktivsauerstoff (MPS) Oxígeno Activo (MPS) | Oxygène Actif (MPS) Ossigeno Attivo (MPS) Range ± 0.0 – 5.0 0.5 ppm (mg/l) 5.0 – 15.0 1.3 ppm (mg/l) 15.0 – 25.0 3.8 ppm (mg/l) 25.0 –...
  • Page 205 Ammonium Range ± 0.0 – 2.5 0.2 ppm (mg/l) 2.5 – 6.5 0.6 ppm (mg/l) 6.5 – 11.0 1.7 ppm (mg/l) 11.0 – 13.5 2.3 ppm (mg/l) 13.5 – 18.0 3.0 ppm (mg/l) Bromine | Brom | Bromo | Brome | Bromo Range ±...
  • Page 206 Tolerances | Toleranzen | Tolerancias | Tolérances | Tolleranze Chloramine ± Range 0.00 – 2.00 0.10 ppm (mg/l) 2.00 – 3.00 0.23 ppm (mg/l) 3.00 – 4.00 0.75 ppm (mg/l) 4.00 – 8.00 1.00 ppm (mg/l) Chlorine | Chlor | Cloro | Chlore | Cloro ±...
  • Page 207 Chlorine Dioxide | Chlordioxid Dióxido De Cloro | Dioxyde De Chlore Biossido Di Cloro Range ± 0.00 – 2.00 0.19 ppm (mg/l) 2.00 – 6.00 0.48 ppm (mg/l) 6.00 – 10.00 1.43 ppm (mg/l) 10.00 – 11.40 1.90 ppm (mg/l) 11.40 –...
  • Page 208 Tolerances | Toleranzen | Tolerancias | Tolérances | Tolleranze Hydrogen Peroxide | Wasserstoffperoxid Peróxido De Hidrógeno | Peroxyde D'Hydrogène Perossido Di Idrogeno – (LR) Range ± 0.00 – 0.50 0.05 ppm (mg/l) 0.50 – 1.50 0.12 ppm (mg/l) 1.50 – 2.00 0.36 ppm (mg/l) 2.00 –...
  • Page 209 Nitrate Range ± 0.00 – 1.00 0.07 ppm (mg/l) 1.00 – 2.00 0.17 ppm (mg/l) 2.00 – 3.00 0.51 ppm (mg/l) 3.00 – 4.00 0.68 ppm (mg/l) 4.00 – 5.40 0.85 ppm (mg/l) Ozone | Ozon | Ozono Range ± 0.00 –...
  • Page 210 Tolerances | Toleranzen | Tolerancias | Tolérances | Tolleranze Phosphate LR Range ± 0.00 – 1.00 0.07 ppm (mg/l) 1.00 – 2.00 0.17 ppm (mg/l) 2.00 – 3.00 0.51 ppm (mg/l) 3.00 – 4.00 0.68 ppm (mg/l) 4.00 – 5.40 0.85 ppm (mg/l) Phosphate HR Range...
  • Page 211 Range ± 0.00 – 1.00 0.07 ppm (mg/l) 1.00 – 2.00 0.17 ppm (mg/l) 2.00 – 3.00 0.51 ppm (mg/l) 3.00 – 4.00 0.68 ppm (mg/l) 4.00 – 5.40 0.85 ppm (mg/l) Sulphate Range ± 0.00 – 1.00 0.07 ppm (mg/l) 1.00 –...
  • Page 212 Tolerances | Toleranzen | Tolerancias | Tolérances | Tolleranze Urea | Harnstoff | Urée Range ± 0.00 – 0.30 0.05 ppm (mg/l) 0.30 – 0.60 0.06 ppm (mg/l) 0.60 – 1.00 0.09 ppm (mg/l) 1.00 – 1.50 0.12 ppm (mg/l) 1.50 –...
  • Page 213 ® normal domestic waste. The manufacturer of this device, Water-i.d. GmbH, Daimlerstr. 20, D-76344 Eggenstein will dispose of your PoolLab 2.0 Photometer free of charge (not ® including costs of sending the device to us). Send your PoolLab for disposal – freight prepaid –...
  • Page 214 Federal Republic of Germany represented by the general manger Dipl. Ec. Andreas Hock ® here-with declares as follows: The product “PoolLab 2.0" complies with the requirements of the following standards for: ETSI EN 300 328 (V2.2.2) EN 62479 (2010) ETSI EN 301 489-1 (V2.2.3) ETSI EN 301 489-17 (3.2.4)
  • Page 215 FCC Compliance Statement IC Licence-Exempt RSS Compliance Statement FCC: FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 216 RF exposure requirements, a minimum separation distance of XX mm must be maintained between the user's body and the handset, including the antenna. Third party belt-clips, holsters, and similar accessories used by this device should not contain any metallic components. Body-worn accessories that do not meet these requirements may not comply with RF exposure requirements and should be avoided.
  • Page 217 ICES: This device complies CAN ICES-003(B) / NMB-003(B) IC Warning: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
  • Page 218 UKCA/CE-RED: , RED2014/53/EU S.I. 2017/1206 Declaration of Conformity Hereby, XXXXXX declares that this XXXXX product is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU and the Radio Equipment Regulations 2017 (S.I. 2017/1206). A copy of the Declaration of conformity can be found at WWW.XXXX.COM.
  • Page 219 Specific Absorption Rate (SAR) information: The SAR limit adopted by USA and Canada is 1.6 watts/kilogram (W/kg) averaged over one gram of tissue. The highest SAR value reported to the Federal Communications Commission (FCC) and the Industry Canada (IC) for this device type when it is properly worn on the body is 1.6 W/kg.
  • Page 220 Canada ISED Statement This device complies with Part 15 of the FCC Rules [and contains licenseexempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS standard(s)]. Operation is subject to the following two conditions: (1)this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
  • Page 221 Legislation Name Legislation Number Further identification Electromagnetic Regulations 2016 Electromagnetic Compatibility (EMC) Compatibility Regulations (S.I. 2016/1091) Electrical Equipment Safety Regulations 2016 (Safety) Regulations (S.I. 2016/1101) Radio Equipment Regulations 2017 Radio Equipment Regulations (S.I. 2017/1206) Restriction of the Use of Regulations 2012 Certain Hazardous RoHS Substances in Electrical and (S.I.
  • Page 222 UK Conformity Assessed We, Water-i.d. GmbH Germany, hereby certify our responsibility, that the following product: PoolLab 2.0 Photometer, is tested to and conforms with the essential test suites included in the following standards, which are in force within the UK: Standards Regulations 2016 (S.I.
  • Page 223 TELEC (MIC) / IMDA Declaration of Conformity (Japan / Singapore) We, Water-i.d. GmbH Germany, hereby declare that the product/model PoolLab 2.0 was certified for type certification pursuant to Article 2, paragraph 1, item 19. Tests performed: • Band U-NII-2A • Band U-NII-2C •...
  • Page 224 Certificate Of Compliance We hereby certify that the device ® PoolLab 2.0 With it‘s serial number as stated below, has passed intensive visual and technical checks as part of our QM documentation. We confirm the device got factory-calibrated. ® Water–i.d. GmbH (Germany) Andreas Hock, Managing Director ®...