Connecting to the BURLINK interface can be done either with the 9 pin D-SUB connector (RS-232) or with the USB
connector.
RS-232 configuration: 9600Baud, 8bit, parity: none, 1 stop bit, no hardware handshake
A USB device driver needs to be installed when using the USB connector. System requirements for using the USB
software are either WINDOWS 2000 or WINDOWS XP operating system.
Following are listed the possible commands to control the CD player 069. All commands needs to be sent in capital
letters finished with a "carriage return" \r .
POWON\r
POWOFF\r
PLAY\r
PAUSE\r
STOP\r
SKIPFW\r
SKIPBW\r
FORW\r
BACKW\r
FORWR\r
BACKWR\r
VOLUP\r
VOLDN\r
VOLxx\r
INP+\r
INP-\r
INPDISC\r
INPTORX\r
INPRCA1\r
INPRCA2\r
INPMMI\r
INPANALOG\r
KEY0 to KEY9\r
SCAN\r
SCANON\r
SCANOFF\r

BURLINK

CONNECTIONS
COMMANDS
switches the unit on
switches the unit to standby mode
starts playback of the CD
pauses playback of the CD
stops playback of the CD
skips forward to the following tracks
skips backward to the beginning of the current and previous tracks
starts search forward slow
starts search backward slow
starts search forward fast
starts search backward fast
increases the volume by one step
decreases the volume by one step
sets the volume level to the value xx
switches the inputs of the CD player
switches the inputs of the CD player
activates the internal CD drive
activates the external digital input TORX
activates the external digital input RCA1
activates the external digital input RCA2
activates the external input MMI (optional)
activates the external analog input
for direct track selection
switches the scan function on or off
switches the scan function on
switches the scan function off