W**Aap Series - Bard MULTI-TEC W18AAPA Installation And Service Instructions Manual

Hide thumbs Also See for MULTI-TEC W18AAPA:
Table of Contents

Advertisement

Electrical Specifications – W**AAP Series
Rated
No. Field
Volts
MODEL
Power
&
Circuits
Phase
W18AAPA00, A0Z
1
A05
1
230/208-1
A08
1
A10
1
W24AAPA00, A0Z
1
A04
1
A05
230/208-1
1
A08
1
A10
1
W24AAPB00, B0Z
1
230/208-3
B06
1
W24AAPC00, C0Z
1
460-3
C06
1
W30AAPA00, A0Z
1
A05
1
A08
230/208-1
1
A10
1
A15
1 or 2
W30AAPB00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W30AAPC00, C0Z
1
C06
1
C09
460-3
1
C12
1
C15
1
W36AAPA00, A0Z
1
A05
1
A08
230/208-1
1
A10
1
A15
1 or 2
W36AAPB00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W36AAPC00, C0Z
1
C06
1
C09
460-3
1
C12
1
C15
1
W42AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W42AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1
W42AAPC00, C0Z
1
C09
460-3
1
C15
1
W48AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W48AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1
W48AAPC00, C0Z
1
C09
460-3
1
C15
1
W60AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W60AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
2
W60AAPC00, C0Z
1
C09
460-3
1
C15
1
W72AAPA00, A0Z
1
A05
1
A10
230/208-1
1 or 2
A15
1 or 2
A20
1 or 3
W72AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
2
W72AAPC00, C0Z
1
C09
460-3
1
C15
1
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing.
CAUTION: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to Note 8 of Table 310 regarding Ampacity
Adjustment Factors when more than three current carrying conductors are in a raceway.
IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all
local codes.
Manual 2100-665A
Page
18 of 51
Single Circuit
Maximum
Field
Minimum
External
Power
Ground
Circuit
Fuse or
Wire
Wire
Ampacity
Ckt. Brkr.
Size
16
20
12
12
30
30
10
10
46
50
8
10
56
60
6
10
21
30
10
10
25
30
10
10
30
30
10
10
46
50
8
10
56
60
6
10
15
20
12
12
22
25
10
10
9
15
14
14
11
15
14
14
26
35
8
10
32
35
8
10
47
50
8
10
58
60
6
10
84
90
4
8
19
20
12
12
24
25
10
10
33
35
8
10
51
60
6
10
9
15
14
14
12
15
14
14
17
20
12
12
21
25
10
10
26
30
10
10
29
35
8
10
32
35
8
10
47
50
8
10
58
60
6
10
84
90
4
8
23
30
10
10
24
30
10
10
33
35
8
10
51
60
6
10
11
15
14
14
12
15
14
14
17
20
12
12
21
25
10
10
26
30
10
10
32
50
8
10
32
50
8
10
58
60
6
10
84
90
4
8
110
125
2
6
25
35
8
10
25
35
8
10
33
35
8
10
51
60
6
10
60
60
6
10
12
15
14
14
17
20
12
12
26
30
10
10
34
50
8
10
34
50
8
10
58
60
6
10
84
90
4
8
110
125
2
6
26
35
8
10
26
35
8
10
33
35
8
10
51
60
6
10
60
60
6
10
12
15
14
14
17
20
12
12
26
30
10
10
38
60
8
10
38
60
8
10
60
60
6
10
86
90
3
8
112
125
2
6
27
40
8
10
27
40
8
10
35
40
8
10
53
60
6
10
N/A
N/A
N/A
N/A
14
20
12
12
18
20
12
12
27
30
10
10
58
60
6
10
58
60
6
10
62
70
6
8
88
90
3
8
114
125
2
6
40
60
8
10
40
60
8
10
40
60
8
10
55
60
6
10
N/A
N/A
N/A
N/A
18
25
10
10
18
25
10
10
27
30
10
10
TABLE 1.1
 Minimum
 Maximum
Circuit
External Fuse or
Ampacity
Ckt. Breaker
Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C
58
26
60
30
58
26
60
30
58
26
60
30
58
52
60
60
58
26
60
30
58
52
60
60
60
26
60
30
60
52
60
60
35
28
40
30
58
26
60
30
58
52
60
60
58
52
52
60
60
40
28
60
30
Multiple Circuit
Field Power
Wire Size
6
10
10
6
10
10
6
10
10
6
6
10
6
10
10
6
6
10
6
10
10
6
6
10
8
10
10
6
10
10
6
6
10
60
6
6
6
10
8
10
10
Ground
Wire Size
10
10
10
10
10
10
10
10
10
10
10
10
10
10