Electrical Specifications - W**Aap Series - Bard W18AAPA Installation Instructions Manual

Multi-tec/th-tune; free cooling unit system; multi-tec wall-mount air conditioner
Table of Contents

Advertisement

Electrical Specifications – W**AAP Series
Rated
No. Field
Volts
MODEL
Power
&
Circuits
Phase
W18AAPA00, A0Z
1
A05
1
230/208-1
A08
1
A10
1
W24AAPA00, A0Z
1
A04
1
A05
230/208-1
1
A08
1
A10
1
W24AAPB00, B0Z
1
230/208-3
B06
1
W24AAPC00, C0Z
1
460-3
C06
1
W30AAPA00, A0Z
1
A05
1
A08
230/208-1
1
A10
1
A15
1 or 2
W30AAPB00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W30AAPC00, C0Z
1
C06
1
C09
460-3
1
C12
1
C15
1
W36AAPA00, A0Z
1
A05
1
A08
230/208-1
1
A10
1
A15
1 or 2
W36AAPB00, B0Z
1
B06
1
230/208-3
B09
1
B15
1
W36AAPC00, C0Z
1
C06
1
C09
460-3
1
C12
1
C15
1
W42AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W42AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1
W42AAPC00, C0Z
1
C09
460-3
1
C15
1
W48AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W48AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1
W48AAPC00, C0Z
1
C09
460-3
1
C15
1
W48AAPQ00, Q0Z
1
575-3
Q15
1
W60AAPA00, A0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
W60AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
2
W60AAPC00, C0Z
1
C09
460-3
1
C15
1
W60AAPQ00, Q0Z
1
575-3
Q15
1
W72AAPA00, A0Z
1
A05
1
A10
230/208-1
1 or 2
A15
1 or 2
A20
1 or 3
W72AAPB00, B0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
2
W72AAPC00, C0Z
1
C09
460-3
1
C15
1
W72AAPQ00, Q0Z
1
575-3
Q15
1
See footnotes under TABLE 1.2 on page 18
Single Circuit
Maximum
Field
Minimum
External
Power
Ground
Circuit
Fuse or
Wire
Wire
Ampacity
Ckt. Brkr.
Size
16
20
12
12
30
30
10
10
46
50
8
10
56
60
6
10
21
30
10
10
25
30
10
10
30
30
10
10
46
50
8
10
56
60
6
10
15
20
12
12
22
25
10
10
9
15
14
14
11
15
14
14
26
35
8
10
32
35
8
10
47
50
8
10
58
60
6
10
84
90
4
8
19
20
12
12
24
25
10
10
33
35
8
10
51
60
6
10
9
15
14
14
12
15
14
14
17
20
12
12
21
25
10
10
26
30
10
10
29
35
8
10
32
35
8
10
47
50
8
10
58
60
6
10
84
90
4
8
23
30
10
10
24
30
10
10
33
35
8
10
51
60
6
10
11
15
14
14
12
15
14
14
17
20
12
12
21
25
10
10
26
30
10
10
32
50
8
10
32
50
8
10
58
60
6
10
84
90
4
8
110
125
2
6
25
35
8
10
25
35
8
10
33
35
8
10
51
60
6
10
60
60
6
10
12
15
14
14
17
20
12
12
26
30
10
10
34
50
8
10
34
50
8
10
58
60
6
10
84
90
4
8
110
125
2
6
26
35
8
10
26
35
8
10
33
35
8
10
51
60
6
10
60
60
6
10
12
15
14
14
17
20
12
12
26
30
10
10
12
15
14
14
24
25
10
10
38
60
8
10
38
60
8
10
60
60
6
10
86
90
3
8
112
125
2
6
27
40
8
10
27
40
8
10
35
40
8
10
53
60
6
10
N/A
N/A
N/A
N/A
14
20
12
12
18
20
12
12
27
30
10
10
13
20
12
12
24
25
12
12
58
60
6
10
58
60
6
10
62
70
6
8
88
90
3
8
114
125
2
6
40
60
8
10
40
60
8
10
40
60
8
10
55
60
6
10
N/A
N/A
N/A
N/A
18
25
10
10
18
25
10
10
27
30
10
10
14
20
12
12
24
25
10
10
TABLE 1
 Minimum
 Maximum
Circuit
External Fuse or
Ampacity
Ckt. Breaker
Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C Ckt. A Ckt. B Ckt. C
58
26
60
30
58
26
60
30
58
26
60
30
58
52
60
60
58
26
60
30
58
52
60
60
60
26
60
30
60
52
60
60
35
28
40
30
58
26
60
30
58
52
60
60
58
52
52
60
60
40
28
60
30
Multiple Circuit
Field Power
Wire Size
6
10
10
6
10
10
6
10
10
6
6
10
6
10
10
6
6
10
6
10
10
6
6
10
8
10
10
6
10
10
6
6
10
60
6
6
6
10
8
10
10
Manual
Page
Ground
Wire Size
10
10
10
10
10
10
10
10
10
10
10
10
10
10
2100-678
17 of 24

Advertisement