Stylus on-centre adjustment with probe holders and sockets

Stylus on-centre adjustment

Stylus position is established using a setting gauge or dial test indicator .
Lathes – inspection
The stylus is set to the same height as the spindle centre line to avoid errors when gauging diameters . The
stylus tip position should correspond to the normal tool tip position for efficient programming.
1 .
MA4 90° adaptor
The probe is set through 360° .
2 .
FS3 adjustable holder
The holder pivots on two Ø6 mm balls. Two opposing screws permit ±4° fine rotational adjustment.

Lathes and machining centres

3 .
Tool setting
The square tip of the stylus must align exactly with the machine's X and Y axes (machining centres)
and X axis (lathes) . Coarse alignment is obtained by adjusting the stylus tip . The optional
FS1 socket provides ±4° fine rotational adjustment.
Stylus
Extension
LP2
probe
FS1
socket
FS3 holder
Coarse adjustment
Fine adjustment
www.renishaw.com/lp2
3-13