ELECTRICAL WIRING DIAGRAMS

ELECTRICAL CONNECTION OF THE AIR CONDITIONER

• The electrical connections can be found under the protective plastic cover. Remove
this from the side of the outdoor unit to gain access to the electrical connections.
• Connect the indoor power and control wires with the matching outdoor wire as per
the electrical diagram.
• Do not attempt to connect the wires in a different way to the diagram on the air
conditioner as this could damage the unit and invalidate the warranty.
• Secure the wires and replace the cover before operating the unit.
• The appliance should be installed in accordance with national wiring regulations.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or a suitably qualified person in order to avoid a hazard.
• The air conditioner electrical wiring must follow the specific country regulations. If
power cord is damaged must be replace by a qualified electrician.
Indoor
Unit
Brown
L
Blue
N
Black or White
1
L
N
To Power
Supply
35
Outdoor
Unit
Yellow/Green
L
N
1