Garbled display on the configuration terminal

Symptom
The configuration terminal has garbled display when the router is powered on.
Solution
To resolve the issue:
1.
Verify that the following settings are configured for the terminal:
Baud rate—9600.
Data bits—8.
Parity—None.
Stop bits—1.
Flow control—None.
2.
If the issue persists, contact H3C Support.

No response from the serial port

Symptom
The serial port on the router does not respond.
Solution
To resolve the issue:
1.
Verify that the serial cable is in good condition and the serial port settings are correct.
2.
If the issue persists, contact H3C Support.

Restoring the factory settings

Scenario 1

Symptom
When you replace the router, the router password is lost. As a result, you cannot log in to the
router and do not know the router configuration.
Solution
Because the router is replaced, you do not need to save the configuration of the router. In this case,
you can press the RESET button for more than 4 seconds to reboot the router and restore the
factory settings. Then, you can use the username and password shipped with the router to log in to
the router.
When the router configuration must be saved and you have a console cable, you can log in to the
router from the BootWare menu.

Scenario 2

Symptom
After the configuration is modified, the network connectivity is lost. When you check the
configuration, the configuration is very complicated and it is hard to locate the errors. In this case,
you must configure the router again.