Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss Holip HLP-C+ Series

  • Page 3: Table Of Contents

    HLP-C Inverters Contents Ⅰ.Introduction………………………………………… 1 1.Checks upon Delivery …………………………………………2 2.Nameplate Information of HLP-C Series……………………3 Ⅱ. Safety Precautions ……………………………… 4 1.Before the Power Up ………………………………………… 4 2.During the Power Up………………………………………… 6 3.Duing the Operation …………………………………………… 6 Ⅲ. Standard Specifications ………………………… 8 1.Particular Specifications ……………………………………...
  • Page 4 HLP-C Inverters Ⅷ. Function List ……………………………………… 21 Ⅸ. Descriptions of Functions ………………………28 Ⅹ. Care & Maintenance, Fault Information and Troubleshooting ……………………………… 80 1.Precautions about Inspection and Maintenance ………… 80 2.Periodical Inspection and Maintenance items…………… 80 3.Fault indication and troubleshooting ……………………… 81 4.Faults and Analysis …………………………………………...
  • Page 5: Ⅰ.introduction

    HLP-C Inverters I.Introduction Thank you for purchasing and using the general-purpose inverter of HLP- C Series of multi-functions and high performance. The inverter of HLP- C Series has been developed on basis of HLP-A Series keeping the main functions of HLP-A Series and with additional functions on request of customers as well as smaller size.
  • Page 6: Checks Upon Delivery

    HLP-C Inverters ● Do not check components and signals on the circuit boards. ● Do not dissemble or modify the any internal connecting cord, wiring or component of the inverter by yourself. ● Be sure to make correct ground connection of the earth terminal of the inverter.
  • Page 7: Nameplate Information Of Hlp-C

    HLP-C Inverters ● Check if there is something wrong on the inner parts, wiring and circuit board. ● Check if each terminal is tightly locked andif there is any foreign article insie the inverter. ● Check if the operator buttons are all right. ●...
  • Page 8: Ⅱ. Safety Precautions

    HLP-C Inverters II.Safety Precautions ⑴ Before the Power Up Caution ● Check to be sure that the voltage of the main circuit AC power supply matches the input voltage of the inverter. Caution ● E symbol is the ground terminal. Be sure to make correct ground connection of the earth terminals of the motor and the inverter for safety.
  • Page 9 HLP-C Inverters ● The inverter can only be used at the places accredited by our company. Any unauthorized working environment may have the risks of fire, gas explosion, electric shock and other incidents. ● Install a cooling fan or other cooling device when installing more than one inverters in the same enclosure so that the temperature inside the enclosure be kept below 40 ℃...
  • Page 10: During The Power Up

    HLP-C Inverters will cause malfunctions, tripping protecton and damages of components of the inverter. Please remove them as shown in the above diagram. ● The function of STOP switch is only valid after it is set. Its use is different with the emergency stop switch. Be careful when using it.
  • Page 11 HLP-C Inverters Caution ● Do not touch the heat sink, braking resistor, or other heat elements. These can become very hot. ● Be sure that the motor and machine is within the applicable speed ranges before starting operation because the inverter is quite easy to run from lower speed to higher speed.
  • Page 12: Ⅲ. Standard Specifications

    HLP-C Inverters III. Standard Specifications ⑴ Particular Specifications Suitable Inverter Output Power Type Input Voltage Motor Capacity Current (KW) ( KW ) ( KVA ) (A) HLPC 0D7543B 0.75 0.75 3φ380V HLP C 01D543B 50/60Hz HLP C 02D243B HLP C 00D423B Single &...
  • Page 13 HLP-C Inverters Torque increase settable by max. 10.0%. Torgue Control The starting torque can reach 150% at 1.0Hz. 6 multi-input terminals for 8–speed steps control, program operation, switch of Multi-function 4-steps Accel/Decel, UP/DOWN function, input terminals counter, external emergency stop and other functions.
  • Page 14: Ⅳ. Storage And Installation

    HLP-C Inverters IV.Storage & Installation ⑴ Storage The inverter must be kept in its original package box before installation. Pay attention to the followings when keeping it in storage if the inverter is not used for the time being: ● It must be stored in a dry place without rubbish or dust. ●...
  • Page 15 HLP-C Inverters ● The inverter must be installed vertically and to ensure the smooth ventilation for effective cooling. ; ● If there is any instability when installing the inverter, please put a flat board under the inverter bottom base and install again.
  • Page 16: Ⅴ. Wiring

    HLP-C Inverters V. Wiring ⑴ Main Circuit Schematic Diagram Power supply: Verify that the inverter’s rated voltage coincides with AC power supply voltage to avoid a damage of the inverter. No fuse breaker: Refer to the related list. Ground fault circuit interrupter : Use one of anti-high harmonic.
  • Page 17: Terminals Description

    HLP-C Inverters ⑵ Function Description of Circuit Terminals 1. Main Circuit Terminals Arrangement 2. Control Circuit Terminals Arrangement FA FB FC DRV FOR REV RST SPL SPM SPH GND AM VI AI +10V 3. Function description of main circuit terminals Symbol Function Description Input terminals of AC line power.(230V class, for R.S.T...
  • Page 18: Basic Connection Diagram

    HLP-C Inverters Symbol Function Description Factory setting Power supply for analog +10V freqency A n a l o g f r e q u e n c y 0~+10V corresponding to the reference input (voltage) highest operating frequency 4 ~2 0 m A c o r r e s p o n d i n g A n a l o g f r e q u e n c y t o t he h ig he s t op e r at i ng reference input (current)
  • Page 19: Precautions On Wiring

    HLP-C Inverters The following diagram shows the factory standard connection of Model HLP-C (4) Precautions on Wiring a : For main circuit wiring: ● While wiring the sizes and specifications of wires should be selected and the wiring should be executed according to the electrical engineering regulations to ensure the safety.
  • Page 20 HLP-C Inverters be connected between the motor and the output terminals (U.V.W) of the inverter. ● The main circuit wire must be enough far away from other control equipments. ● When the wiring between the inverter and the motor exceeds 15 meters for 230V class or 30 meters for 440V class, much higher dV/dT will be produced inside the coil of motor, which will cause the destroy to the interlayor insulation of motor.

Table of Contents