ICP DAS USA MAVIS IM-30 User Manual page 91

Ieee 1394 camera
Table of Contents

Advertisement

IMC_StrobeTimeBase_SetDurationTime
Syntax:
Visual C++ 6.0 / Boland C
short IMC_StrobeTimeBase_SetDuratio
long Value);
Visual Basic 6.0
IMC_StrobeTimeBase_SetDurationTime
As Long) As Integer
C#.NET 2003
Mavis. IMC_StrobeTimeBase_SetDurationTime(IntPtr Camera_Handle, Int32 Value);
Description:
This function set the Duration Time of Strobe. This function is workable only for the
Output Ports that are configured to STROBE_SIGNAL. The camera needs be
initialized with IMC_Camera_Init().
Parameters:
Camera_Handle
Value
Return:
ERROR_SUCCESSFUL
ERROR_CAMERA_CREATE
ERROR_DEVICE_UNINIT
ERROR_INVALID_CAMERA
ERROR_SOURCE_NOT_SUPPORT
++ Builder 6.
The handle for MAVIS camera. Use the handle gotten from the
'pHandle' parameter of IMC_Camera_Init().
The Duration Time of Strobe Control and allows value from 1
~85. By default, the Value is setting on 1.
- 91 -
0:
nTime (HA
NDLE Camera_Handle, unsigned
(ByVal Camera_Hand
Successfully
The Camera_Handle is NULL.
The specific camera has not been
initialized.
The handle is invalid.
The source signal is not supported by that
specific output port.
le As Long, ByVal Value

Advertisement