current settings is 5.
Formula 1:
Formula 2:
Max. Frames/s = 1 / (5 x 125us)
Max. Frames/s = 1600
Formula 3:
Max. Frames/s = 1 / (1000 us + 28us)
Max. Frames/s = 972.76
By using the calculations above, the AOI for this particular scenario can be
calculated at 269 frames per second.

1.4.2 Test Pattern

The MAVIS IM-30/IM-100 series cameras offer an internal generated test
pattern for testing camera transmission. The test pattern will show a gray
bar running diagonally, moving upwards at 1pixel/frame.
When setting camera to test pattern mode, then camera will
keep this configuration even after rebooting the camera. Please
be sure to disable test pattern mode after your test completed
testing.
Max. Frames/s = 1 / (((240 + 2) x 15.28us) + 15.28us)
Max. Frames/s = 269.2
Figure 1-2: MAVIS IM-30/IM-100 gray bar test pattern