ICP DAS USA MAVIS IM-30 User Manual page 84

Ieee 1394 camera
Table of Contents

Advertisement

IMC_Trigger_Disable
Syntax:
Visual C++ 6.0 / Boland C++ Builder 6.0:
short IMC_Trigger_Disable ( HANDLE Camera_Handle);
Visual Basic 6.0
IMC_Trigger_Disable (ByVal Camera_Handle As Long) As Integer
C#.NET 2003
Mavis.IMC_Trigger_Disable( IntPtr Camera_Handle);
Description:
This function disables the External Trigger. The camera needs be initialized with
IMC_Camera_Init().
Parameters:
Camera_Handle
Return:
ERROR_SUCCESSFUL
ERROR_CAMERA_CREATE
ERROR_DEVICE_UNINIT
ERROR_INVALID_CAMERA
The handle for MAVIS camera. Use the handle gotten from the
'pHandle' parameter of IMC_Camera_Init().
Successfully
The Camera_Handle is NULL.
The specific camera has not been initialized.
The handle is invalid.
- 84 -