If the system-level diagnostics tests...
Were completed without any failures
Resulted in some test failures
Then...
1. Clear the status logs:
clearstatus
2. Verify that the log was cleared:
device status
The following default response is
displayed:
SLDIAG: No log messages are present.
3. Exit Maintenance mode on both
controllers:
halt
The system displays the LOADER prompt.
Attention: You must exit Maintenance
mode on both controllers before
proceeding any further.
4. Enter the following command on both
controllers at the LOADER prompt:
ontap
5. Return the controller to normal operation:
If your system is
running ONTAP...
With two controllers
in the cluster
With more than two
controllers in the
cluster
You have completed system-level diagnostics.
Determine the cause of the problem.
1. Exit Maintenance mode:
2. Perform a clean shutdown, and then
disconnect the power supplies.
3. Verify that you have observed all of the
considerations identified for running
system-level diagnostics, that cables are
securely connected, and that hardware
components are properly installed in the
storage system.
4. Reconnect the power supplies, and then
power on the storage system.
.
Chapter 4
Hardware replacement procedures
sldiag device
sldiag
boot_
Then...
Issue these
commands: node::>
cluster ha modify
-configured true
node::> storage
failover modify
-node node0
-enabled true
Issue this command:
node::> storage
failover modify
-node node0
-enabled true
halt