Maintenance; Error Code - Sinclair SWH-200DE Service And Installation Manual

Table of Contents

Advertisement

SINCLAIR

1 Error Code

The water heater stops operation and the wired controller displays E1.
The water heater stops operation and the wired controller displays E3
The water heater stops operation and the wired controller displays C5
The water heater stops operation and the wired controller displays E4.
The water heater stops operation and the wired controller displays E5
The water heater stops operation and the wired controller displays E6.
The water heater stops operation and the wired controller displays F3.
The water heater stops operation and the wired controller displays F4.
The water heater stops operation and the wired controller displays F6.
The water heater stops operation and the wired controller displays Fd.
The water heater stops operation and the wired controller displays FE.
The water heater stops operation and the wired controller displays FL.
The water heater stops operation and the wired controller displays L6.
The water heater stops operation and the wired controller displays PL
The water heater stops operation and the wired controller displays PH
The water heater stops operation and the wired controller displays PA
The water heater stops operation and the wired controller displays H5
The water heater stops operation and the wired controller displays HC
The water heater stops operation and the wired controller displays Lc
The water heater stops operation and the wired controller displays Ld
The water heater stops operation and the wired controller displays P0
The water heater stops operation and the wired controller displays P5
AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL

MAINTENANCE

Symptom
System high pressure protection.
Refrigerant-lacking protection
Malfunction of jumper cap
Discharge high temperature protection.
Overload protection of compressor
Communication malfunction.
Malfunction of outdoor ambient temperature
sensor
Malfunction of discharge temperature sensor.
Malfunction of tube temperature sensor for
outdoor heat exchanger.
Malfunction of suction temperature sensor.
Malfunction of upper temperature sensor of
water tank.
Malfunction of lower temperature sensor of
water tank.
Unit's capacity is insufficient.
Low voltage protection for drive DC bus bar of
inverter
malfunction
High voltage protection for drive DC bus bar of
inverter compressor
Drive
DC
compressor (input side)
Drive IPM module protection of inverter
compressor
Drive PFC protection of inverter compressor
Failure startup of inverter compressor
Phase-lacking protection of inverter compressor
Drive module reset of inverter compressor
Overcurrent protection of inverter compressor
51
Error Description
compressor
or
voltage
current
protection
of
dropping
inverter