Sinclair SWH-200DE Service And Installation Manual page 28

Table of Contents

Advertisement

SINCLAIR
(6) Build a drainage ditch around the foundation to discharge the condensate water.
(7) If the outdoor unit is installed on the roof, check the intensity of the building and take waterproof
measures.
(8) If a u-steel foundation is adopted, the structure must be designed with sufficient rigidity and
strength.
Minimum width: 100 mm
This distance is determined based on the actual size of the unit.
If the wall-mounting mode is adopted, install the outdoor unit of water heat on the load bearing wall.
First, drill holes based on the bolt size for support and bracket installation, then install expansion bolts
into the holes before installing the supports and brackets. Last, install the outdoor unit onto the supports
and brackets and fix it with bolts.
3.1.5 Requirements on Vibration Reduction
The outdoor unit of water heater must be fixed securely. If the outdoor unit vibrates obviously, apply
a damping rubber pad between the bottom corner of outdoor unit and the foundation or support board.
3.1.6 Connection of the Outdoor Unit and Water Tank
Connect the outdoor unit to the water tank using the refrigerant pipe configured upon delivery. For
details, see Section 5 Refrigerant Pipe Design in this chapter.
NOTE: Because there many factories make the produce, the height and type of Refrigerant in and
Refrigerant out of the water has delicate difference, for details, refer to the actual product delivered.
AIR SOURCE HEAT PUMP WATER HEATER SERVICE MANUAL
Anchor bolt with a nominal
diameter of 12 mm
Proportion of the cement, sand,
and stone for the concrete: 1:2:4
Figure 3-4 Installation diagram
25
Drain tank:
100 mm × 20 mm