Configuration; Configure For Sdi2 Control Panels; Configure For Sdi Or Option Bus Control Panels; Plug And Play Configuration - Bosch B426 Installation And Operation Manual

Conettix ethernet communication module
Table of Contents

Advertisement

Conettix Ethernet Communication
Module
5

Configuration

You can configure the B426 using one of the methods described in this section for your
control panel type.
5.1

Configure for SDI2 control panels

Notice!
By default, when connecting a field replacement B426 to an existing SDI2 control panel, the
control panel overrides the module settings. To keep custom module settings when you
connect a module to a configured control panel, you must disable Panel Programming Enable
using web-based configuration, prior to connecting to the SDI2 bus.
Address-only configuration conditions
An SDI2 control panel automatically configures a newly connected module.
1.
2.
3.
4.
The control panel stores the module settings and automatically programs a defaulted module
when connected. To override automatic module programming, use the web configuration to
set the Panel Programming Enable parameter to NO before installing.
5.2

Configure for SDI or option bus control panels

5.2.1

Plug and Play configuration

When installing under the following conditions, the B426 needs no further configuration:
5.2.2

Web-based configuration

For installations where additional non-default settings are required, a web-based configuration
menu is available.
Notice!
You cannot access the configuration web pages for a module if the module is connected to a
GV4 Series or B Series control panel and the Web Access Enable option is set to No. No is the
default value for GV4 Series and RPS while the device is connected.
Determine the module's hostname or IP address by one of the following methods (with the
address switch in any position):
Bosch Security Systems, Inc.
Ensure the B426 is new, or defaulted to the factory settings (refer to Factory Default page,
page 25).
Set the address switch to the correct address for the control panel (SDI2 control panels
use address 1 or 2).
Program the control panel communication settings using RPS or the keypad.
Connect the module to the control panel bus and apply power.
DHCP is available on your network.
AES encryption is not required.
Default B426 port settings (UDP on Port 7700) are permitted by the network
administrator.
Locate the IP address in the table on the DHCP server (networked modules ).
Use the Installer menu of an SDI2 control panel keypad (D9412GV4/D7412GV4 and
B5512/B4512 only).
Use AutoIP to direct connect from your PC to the B426. Within 60 sec, the B426
temporarily assumes address 169.254.1.1 for configuration.
Installation and Operation Guide (UL)
Configuration | en
13
2013.08 | 02 | F.01U.281.208