Step
10. Remove 4-way valve assy
Unsolder the welding joints connecting the 4-way valve
assy, remove the 4-way valve.
Note:
Before unsoldering the welding joint, wrap the 4-way
valve with a wet cloth completely to avoid damage to
the valve caused by high temperature.
11. Remove electric expansion valve sub-Assy
Unsolder the spot weld of electric expansion valve sub-
Assy and condenser, and then remove the electric
expansion valve sub-Assy.
Note:
When unsoldering the spot weld, wrap the electric
expansion valve sub-Assy with wet cloth completely to
avoid damaging the valve due to high temperature.
12. Remove clapboard assy
Remove the screws fixing the clapboard assy and then
remove the clapboard assy.
72
Procedure
Service Manual
4-way valve assy
Electric expand
valve fitting
Electric expansion
valve sub-Assy
Clapboard assy