Omron NX502-1 Series User Manual page 43

Machine automation controller cpu unit
Table of Contents

Advertisement

Boo
Bit strings
lean
DstNetAdr
CommPort
SrcDat[] ar-
ray
SendSize
DstArea
DstCh
Option
Function
When Execute changes from FALSE to TRUE, SrcDat[] is written to the area at the send destination
specified by DstNetAdr, CommPort, DstArea, and DstCh.
The data type of DstNetAdr is structure_sDNET_ADR. The specifications are shown below.
Variable
DstNetAdr
NetNo
NodeNo
UnitNo
The data type of CommPort is enumeration_ePORT.
The meaning of the enumerator of enumeration_ePORT is as follows.
Enumerator
_NONE
The send destination is not a serial port (host link mode).
The data type of DstArea is enumeration_eAREA.
The meaning of the enumerator of enumeration_eAREA is as follows.
Enumerator
_CIO
Core I/O Area, Work Area, etc.
_WR
Work Area
_HR
Holding Area
_TIMER
Timer Area
_COUNTER
Counter Area
_DM
Data Memory Area
_EM0
0 bank area of Expansion Memory Area
NX-series CPU Unit FINS Function User's Manual (W596)
Refer to Function on page 3-5 for details on the structure _sDNET_ADR.
For enumeration_ePORT enumerator, refer to Function on page 3-5.
OK
OK
For enumeration_eAREA enumerator, refer to Function on page 3-5.
OK
Refer to Function on page 3-5 for details on the structure _sRESPONSE.
Name
Contents
Network ad-
Network address at
dress at send
send destination
destination
Network ad-
Network address
dress
Node address Node address
Unit address
Unit address
Meaning
Meaning
Integers
Data type
_sDNET_AD
R
USINT
USINT
BYTE
3 Client Function
Real
Times, durations,
num-
dates, and text strings
bers
Initial
Valid range
Unit
value
---
---
---
0 to 127
0
Depends on
---
the data type
Depends on
16#00
the data type
3