Overview
The Wireless CO₂ Sensor (RCT) uses wireless
technology to communicate accurate indoor
CO
, temperature, and relative humidity
2
readings to compatible controllers.
The solar panel harvests and stores sufficient
energy for normal operation. A CR2032
battery is used for calibrations and backup
assistance if required.
This document covers installation, testing, and
basic setup of the RCT. The product package
includes the sensor and a battery.
Prepare for Installation
To ensure optimal function, consider the
installation environment and the following
guidelines:
For indoor, commercial controls use only. Operating temperature
-25°C to 50°C (-13°F to 122°F) and relative humidity 5%–95%.
High density construction materials and large metal appliances or
fixtures in the space may disrupt wireless transmissions.
Install the sensor within range of the gateway or interface to the
monitoring system, 24 m (80 ft) unobstructed view. Consider adding
a repeater to extend the wireless signal, if required.
CR2032 coin cell battery is provided with the sensor. Install the
battery or activate it if factory-installed by removing the protective
plastic tab in the battery housing. See
Find a suitable location that has good light exposure. Use the
Level Test on page 3
Plan for at least 20 minutes outdoors for the sensor to calibrate an
ambient air baseline. See
Supplies required to install (not provided):
Two #6 screws, double-sided tape, or Velcro
Corporate Headquarters n Middleton, WI, USA | +1 608 831 4116
Web
echoflexsolutions.com
©2023 Echoflex Solutions, Inc. Trademark and patent
Product information and specifications subject to change.
Echoflex intends this document to be provided in its entirety.
8188M2100 Rev C Released 2023-04
to confirm adequate light exposure.
| Email
info@echoflexsolutions.com
Battery Power on
Outdoor CO ₂ Calibration on
| Support
service@echoflexsolutions.com
info: echoflexsolutions.com/ip
LEDs behind
solar panel
Function
button
page 3.
page 4.
®
RCT
Light

Advertisement

Table of Contents
loading

Summary of Contents for ETC echoflex RCT

  • Page 1 Echoflex Installation Guide Wireless CO₂ Sensor Overview The Wireless CO₂ Sensor (RCT) uses wireless technology to communicate accurate indoor , temperature, and relative humidity readings to compatible controllers. LEDs behind The solar panel harvests and stores sufficient solar panel energy for normal operation. A CR2032 battery is used for calibrations and backup assistance if required.
  • Page 2: Installation

    Echoflex Installation Guide Wireless CO₂ Sensor Installation Use hand tools when installing. Over-torquing with a power tool can damage the sensor. The sensor’s removable back plate can be mounted on most surfaces. Note: Consider linking the sensor while you have access and before replacing the cover, see Send a Teach Message below.
  • Page 3: Battery Power

    Echoflex Installation Guide Wireless CO₂ Sensor Battery Power A battery is not required for normal operation if the sensor receives adequate natural or artificial light. See the table in the Light Level Test below. A CR2032 battery is required to run the Outdoor CO ₂...
  • Page 4: About Calibration

    Echoflex Installation Guide Wireless CO₂ Sensor 2. Press and hold the [Function] button again until the green LED stops blinking. The green LED then repeats a number of blinks according to the detected light level. The sensor reevaluates the light level every two seconds.
  • Page 5 Echoflex Installation Guide Wireless CO₂ Sensor CO₂ Calibration Setting The sensor provides an Automatic Background Calibration (ABC) option that can be set indoors. ABC is enabled by default. ABC is a feature that measures the lowest level of CO that occurs over a three-week period to establish an ambient air baseline and assign the value 420 ppm to this lowest value.
  • Page 6: Transmission Intervals

    Echoflex Installation Guide Wireless CO₂ Sensor The chart illustrates CO concentration and how values correspond to ventilation rates (2,600=Red; 1,500=Yellow; 400=Green). Note: The sensor automatically corrects for altitude. Pressure compensation is factored into CO readings using 3% for every 300 m (1000 ft). Current General Range The sensor blinks a color LED every 15 seconds to indicate the current general range of CO...
  • Page 7: Fcc Compliance

    Echoflex Installation Guide Wireless CO₂ Sensor Compliance For complete regulatory compliance information, see the Wireless CO₂ Sensor datasheet at echoflexsolutions.com. FCC Compliance Echoflex Wireless CO₂ Sensor (For any FCC matters): Echoflex Solutions, Inc. 3031 Pleasant View Road Middleton, WI 53562 +1 (608) 831-4116 echoflexsolutions.com This device complies with Part 15 of the FCC Rules.
  • Page 8 Echoflex Installation Guide Wireless CO₂ Sensor Wireless CO₂ Sensor Page 8 of 8 Echoflex...