Field bus module

Advertisement

Quick Links

Device description
FieldBusModule FBM45
with four analog inputs and outputs as
well as a connection to a
FrontSwitchingModule FSM42 or FSM44
for manual operation
Kieback & Peter
GmbH & Co KG
Tempelhofer Weg 50
D-12347 Berlin
Telefon 030 / 600 95-0
Telefax 030 / 600 95 164
with 4 analog inputs and outputs as well as a connection to a FSM42 or FSM44
Safety precautions ...................................................................................... Page 2
Qualified expert personnel........................................................................... Page 2
Applications ................................................................................................. Page 3
Type ............................................................................................................ Page 3
Technical data.............................................................................................. Page 3
Measurements ............................................................................................ Page 4
Mounting ..................................................................................................... Page 4
Installation.................................................................................................... Page 4
Connections ......................................................................................... Page 5
Remote operation................................................................................. Page 6
Local operation..................................................................................... Page 7
Inverting the inputs IN1..IN4 ........................................................................ Page 7
Commissioning .................................................................................. Page 8
Technical data sheet 2.50-30.045-01-en
FBM45 Field Bus Modul

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBM45 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kieback&Peter FBM45

  • Page 1: Table Of Contents

    Technical data sheet 2.50-30.045-01-en FBM45 Field Bus Modul Device description with 4 analog inputs and outputs as well as a connection to a FSM42 or FSM44 FieldBusModule FBM45 with four analog inputs and outputs as well as a connection to a...
  • Page 2: Contents Notice About The Device Description

    Technical data sheet 2.50-30.045-01-en FBM45 Field Bus Modul Device description with 4 analog inputs and outputs as well as a connection to a FSM42 or FSM44 Notice about the device description The description contains information on the fields of application and mounting instructions for the field bus module FBM26.
  • Page 3: Applications

    Four additional analog inputs permit the acceptance of digital data points from the ITS. For stand-alone manual operation, the field bus module FBM45 possesses a QBS interface to the connection of a FrontSwitchingModule FSM. The FBM45 can function in two different types of operation.
  • Page 4: Measurements

    4 analog inputs and outputs as well as a connection to a FSM42 or FSM44 Measurements FBM45 71,6 Mounting The mounting of the FBM45 may only be carried out by qualified expert personnel in a voltage-free control panel! Normschiene...
  • Page 5: Installation

    Technical data sheet 2.50-30.045-01-en FBM45 Field Bus Modul Device description with 4 analog inputs and outputs as well as a connection to a FSM42 or FSM44 Installation Mains voltage 230 V on the relay outputs is possible! The electrical installation of the devices connection may only be carried out by qualified expert personnel, e.g.
  • Page 6: Types Of Operation

    The analog inputs Yin1..4 (0..10 V DC are made available for arbitrary logic operations in the DDC Central Control Unit. The function stated of the field bus module FBM45 are sent back as internal contacts on the field bus to the DDC Central Control Unit and are available there for further processing and logic operations.
  • Page 7: Local Operation

    (connection on FBM inputs Yin1..4). The FBM outputs Yout1..4 are connected to the positioning facilities in the plant. If there is a field bus connection with a setting for the field bus address, the FBM45 acts like a gateway to the remote system.
  • Page 8: Commissioning

    After 10 seconds, a new test cycle is automatically started. The FSM function test is terminated when the switch LED on the FBM45 is switched from Yin to the FBM45 function test, or the address switch is changed from the setting 99.
  • Page 9 FBM45 Field Bus Modul Device description with 4 analog inputs and outputs as well as a connection to a FSM42 or FSM44  Functions test of the FBM45 Switch Yout to set (lower position). The function test state is displayed by the continuous lighting of the LED BUS.