Kieback&Peter FSM21 Device Description

Kieback&Peter FSM21 Device Description

Front switch module

Advertisement

Quick Links

Device Description

FSM21 Front Switch Module

For connection to the FBM38 fieldbus module.
The FSM21 front switch module is used for the direct operation of
1 or 2-stage unit or device switches.
The module functions through macro assignments on the FBM38
fieldbus module. A load/rolling switch with different switching delays can be
set in the macro function.
The FSM21 and FBM38 modules form a single operating unit.
Contents
FSM21 Front Switch Module............................................................................................................................................................. 1
Information About the Device Description ......................................................................................................................................... 2
Safety Instructions ............................................................................................................................................................................ 2
Qualified Technicians........................................................................................................................................................................ 2
Application ........................................................................................................................................................................................ 3
Type .................................................................................................................................................................................................. 3
Technical Data .................................................................................................................................................................................. 3
Mounting ........................................................................................................................................................................................... 4
Installation......................................................................................................................................................................................... 5
Macro Function ................................................................................................................................................................................. 6
Function/Operation............................................................................................................................................................................ 6
Switch stop........................................................................................................................................................................................ 7
Setting the switch stop ...................................................................................................................................................................... 7
LED Settings ..................................................................................................................................................................................... 9
Commissioning ................................................................................................................................................................................. 9
Setting Notes .................................................................................................................................................................................. 10
Kieback&Peter GmbH & Co KG
Tempelhofer Weg 50 · 12347 Berlin, Germany
Telephone: 030 60095-0
Fax: 030 60095 164
E-mail: info@kieback-peter.de
www.kieback-peter.de
Technical Data Sheet 2.50-35.021-01-en Rev
FSM21 Front Switch Module
For connection to the FBM38 fieldbus module.
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FSM21 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kieback&Peter FSM21

  • Page 1: Table Of Contents

    For connection to the FBM38 fieldbus module. FSM21 Front Switch Module For connection to the FBM38 fieldbus module. The FSM21 front switch module is used for the direct operation of 1 or 2-stage unit or device switches. The module functions through macro assignments on the FBM38 fieldbus module.
  • Page 2: Information About The Device Description

    For connection to the FBM38 fieldbus module. I nformation About the Device Description The description contains information for using and installing the FSM21 front switch module. If you have any questions that are not covered by the device description, contact the supplier or manufacturer for further information.
  • Page 3: Application

    For connection to the FBM38 fieldbus module. Application The FSM21 front switch module is operated with the FBM38 fieldbus module, and is used for manual operation of two 1 or 2-stage units, each with two operating and malfunction message displays per control channel.
  • Page 4: Mounting

    For connection to the FBM38 fieldbus module. Mounting The FSM21 front switch module can be inserted in the switchboard door or a 19" KA rack. Two screws are included for mounting the module in a 19" KA rack. The WAS01 set is available as an accessory for wall mounting.
  • Page 5: Installation

    Ensure that this process complies with VDE guidelines and local wiring regulations. Danger The FSM21 front switch module is connected to the QB interface of the FBM38 fieldbus module. The 4-wire QBS connection line can have a maximum length of 200 m.
  • Page 6: Macro Function

    A load/rolling switch with different switching delays can be set in macro 21. Binary inputs 55/IN–58/IN on the FBM38 are defined as malfunction messages by the macro function, and are hown on the signal LEDs (1.3/1.4, 2.3/2.4) on the FSM21. Depending on the operating mode set on the FBM38 ( ), the following is signaled by the signal LEDs (1.1/1.2,...
  • Page 7: Switch Stop

    Technical Data Sheet 2.50-35.021-01-en Rev FSM21 Front Switch Module Device Description For connection to the FBM38 fieldbus module.  Manual/automatic switch 1 and 2 The relay outputs K1/K2 on the FBM38 are controlled as 2 or 1-stage using the manual/automatic switch 1 (unit 1, levels 1.1 and 1.2).
  • Page 8 Technical Data Sheet 2.50-35.021-01-en Rev FSM21 Front Switch Module Device Description For connection to the FBM38 fieldbus module.  Green signal LED (1.1/1.2, 2.1/2.2) with “Remote” operating mode activated Two signal LEDs are found to the right of each manual/automatic switch. They are used to display operating messages on binary inputs 51/IN–54/IN of the FBM38 (e.g.
  • Page 9: Led Settings

    LED Settings The green signal LEDs can be switched off individually (optional). The setting is made using a DIP switch behind the front panel of the FSM21. The corresponding DIP switches are arranged next to the LEDs. LEDs can be...
  • Page 10: Setting Notes

    Technical Data Sheet 2.50-35.021-01-en Rev FSM21 Front Switch Module Device Description For connection to the FBM38 fieldbus module. Setting Notes Project: _________________________________________________________ Plant: _________________________________________________________ Plant position: _________________________________________________________ Commissioning: ____________________________ _____________________ Commissioning technician Date C onnected fieldbus module FBM38 ( Macro 21 (...
  • Page 11 Technical Data Sheet 2.50-35.021-01-en Rev FSM21 Front Switch Module Device Description For connection to the FBM38 fieldbus module. Other setting notes Page 11 / 12...