2.4. Electrical Hook-up

All Electrical Work should be performed in accordance with Local and State Codes, and
NFPA National Electrical Code, Standard #70 by a Qualified and Licensed Electrician .
WARNING: Never perform electrical work while standing in water.
Do not attempt wiring on a live circuit.
WARNING: Do not attempt wiring on a live circuit.
WARNING: Power Supply Voltage must match the voltage marked on the
System Nameplate. Improper wiring may result in system damage.
1. Turn main power switch, located on the AIRaider to the "Off" position.
2. Connect the Jet Pump power cord to the Jet Pump. (Does not apply to 433-S50 or 433-S50X
Systems; pump is factory connected) Note the Jet Pump power cord from the AIRaider is provided
with an electrical receptacle. The Jet Pump may be connected either by connecting a suitable power
lead with plug and plugging into the receptacle or by removing the receptacle from the Jet Pump
power cord and connecting the power cord directly to the pump. Follow wiring instructions located
in the enclosed Jet Pump Manual.
WARNING: Never remove the Receptacle from the Jet Pump Power Cord without connecting the wires thus
exposed to the jet pump, inside the Jet Pump Electrical Enclosure. Always secure the Jet Pump Enclosure
Cover after making electrical connections.
3. On 433-S50X units only the installer may need to disconnect the Armored Cable supplied in order
to install the Pressure Switch. The Armored Cable may require trimming to the desired length before
reconnecting. Connect per the wiring diagram Figure 10, Page 15.
4. Make sure all connections in the control panel are tight.
5. Bring in power to the control panel using the hole provided, either an appropriate strain relief
bushing, or electrical conduit fitting(s), with correctly rated electrical wire or cable must be used in
accordance with all applicable Electrical Codes.
6. Connect the power line to the control panel as shown in the applicable wiring diagram (See Figures
9 and 10 on pages 14 and 15).
7. Connect power line to power source.*
*NOTE: Manufacturer recommends that the AIRaider System be directly wired to the panel on a dedicated
circuit (20 Amp 110-120VAC) from a locally mounted junction box that also contains a receptacle for the ASV
control power. Follow all
IN063 Rev.E
INSTALLATION INSTRUCTIONS
code requirements regarding wire and circuit breaker size.