INSTALLATION INSTRUCTIONS
5. Install pipe/tube from System inlet (Figure 5) to the desired location of the supply from the well
tank. At the supply end a tee is required to accommodate supply from the well and the system bypass
connection. The system inlet is provided with a ¾" Sharkbite Elbow suitable for ¾" Nominal Copper
Tube or Pex Tube, insertion length into Sharkbite Fitting is 1". A System Inlet Valve (normally open
ball valve) is required between the tee and Sharkbite Elbow.
NOTE: A System Inlet Valve (normally open ball valve) is required between the tee and Sharkbite Elbow.
6. Install the pipe/tube between the tees at the desired locations of the supply to house and the supply
from well. A System Bypass Valve (Normally Closed Ball Valve) is required between the tees.
Figure 6
Installed 433 ND System
IN063 Rev.E
Page 10 of 26
3 Saber Way, Ward Hill, MA 01835 | radonaway.com