Electrical Hook-Up - RadonAway AIRaider 433-S50 Instruction & Installation Manual

All residential & small system models
Table of Contents

Advertisement

1
2

2.4. Electrical Hook-up

All Electrical Work should be performed in accordance with Local and State Codes, and
NFPA National Electrical Code, Standard #70 by a Qualified and Licensed Electrician .
WARNING: Never perform electrical work while standing in water.
Do not attempt wiring on a live circuit.
WARNING: Power Supply Voltage must match the voltage marked on the
System Nameplate. Improper wiring may result in system damage.
1. Turn main power switch, located on the AIRaider
2. Connect the Jet Pump power cord to the Jet Pump. (Does not Apply to 433-S50 or 433-S50X
Systems, pump is factory connected) Note the Jet Pump power cord from the AIRaider
with an electrical receptacle. The Jet Pump may be connected either by connecting a suitable power
lead with plug and plugging into the receptacle or by removing the receptacle from the Jet Pump
power cord and connecting the power cord directly to the pump. Follow wiring instructions located
in the enclosed Jet Pump Manual.
Warning: Never remove the Receptacle from the Jet Pump Power Cord without connecting the wires
thus exposed to the jet pump, inside the Jet Pump Electrical Enclosure. Always secure the Jet Pump
Enclosure Cover after making electrical connections.
3. On 433-S50X units only the installer may need to disconnect the Armored Cable supplied in order
to install the Pressure Switch. The Armored Cable may require trimming to the desired length before
reconnecting. Connect per the wiring diagram Figure 8 Page 14.
4. Make sure all connections in the control panel are tight.
5. Bring in power to the control panel using the hole provided, either an appropriate strain relief
bushing, or electrical conduit fitting(s), with correctly rated electrical wire or cable must be used in
accordance with all applicable Electrical Codes.
6. Connect the power line to the control panel as shown in the applicable wiring diagram (See Figures
6, 7, 8, 9 - on pages 12-15).
7. Connect power line to power source *. The required Voltage is either 120V or 240V and is indicated
by an "X" marked in the check box next to either the 120V or 240V marking on the nameplate. Follow
all code requirements regarding wire and circuit breaker size.
* Manufacturer recommends that the AIRaider
dedicated circuit.
IN063 Rev.D 0120
INSTALLATION INSTRUCTIONS
TM
System be directly wired to the panel on a
TM
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
, to the "Off" position.
is provided
TM
Page 11 of 22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Airaider 433Airaider 433-1Airaider 321

Table of Contents