2.1. System Location

When selecting the location for the AIRaider
1. System Plumbing Hook-up. Find a location that will minimize the amount of plumbing
necessary, this is typically in proximity to the well tank.
2. Electrical Hook-up. A dedicated 20 Amp, 110-120VAC circuit power supply is required for
any AIRaider system. This should be in the form of a dedicated junction box with conduit
and a receptacle for plugging in the ASV power adapter. (Figure 4)
*Note: The AIRaider must be hardwired to the dedicated circuit.
It must NOT be connected to power with a flexible cord with
a 3-prong grounding plug!
3. Exhaust Line Venting. The location of the system must
allow for outside venting of the system exhaust above
the eave of the structure. The manufacturer requires that
the exhaust pipe pitch back toward the system (see
Section 2.6).
4. Remote Air Intake. If the system must be installed in an area with questionable air quality
(i.e. furnace room, garage, crawl space) then ducting from the air intake to a remote
location having good air quality may be required.
5. System Must Be Level. The system should not be located on a significant slope as this may
impede system performance.
Place the system in the location acceptable to the customer that maximizes the ease of installation by
considering these five factors. All Local and State codes as well as any applicable AARST, EPA and/
or State Radon standards must be adhered to when locating the AIRaider (i.e. away from electrical
panel, furnace, exits, etc.).
2.2. External Re-Pressurization Pump Installation
This section does not apply to Systems with integral pumps (321-S50X, 433-S50 & 433-S50X Systems).
1. If using a pump attach Mounting Bracket to wall as shown in Figure 5 (page 9). Note bracket hole
height is specific to the pump. Adjust bracket height as required to place pump suction pipe centerline at
the system outlet centerline as specified in Figure 5.
Note: Short horizontal pipe run from system outlet to pump inlet is optimal. If this pump location is impractical because of space constraints the pump may be located
remotely at a higher location, but pump lift, pipe diameter, and equivalent pipe length must comply with limits specified in the pump installation instructions.
Do not mount pump lower than shown as removal of the pump for service may result in tank contents siphoning out onto the floor!
IN063 Rev.E
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
System, five factors should be among those considered:
TM
3 Saber Way, Ward Hill, MA 01835 | radonaway.com
FOR REFERENCE
20 amp outlet
for ASV
Power
Figure 4
Electrical Hookup to Power Supply
Page 8 of 26