8.5

Technical parameters of the I/O port

Electrical characteristics of the binary inputs are in Table 16. Status of the binary input is reported in
the GUI on General Status page or can be retrieved in the Shell via io get bin0 command.
Table 16: Electrical Characteristics of Binary Inputs
Get command output
0
1
The maximum binary output load is 100 mA at 9 ... 48 V.
8.6

System Configuration

The main parameters of the system are listed in Table 17.
Table 17: System Configuration
Other technical parameters
CPU architecture
CPU frequency
Flash Memory
RAM size
Watchdog
RTC
Wieland Electric GmbH | BA001293 | 02/2023 (Rev. A)
Stretch
≤ 0.8 V (0.5 mA))
≥ 2 V
ARM926EJ-S
600 MHz
64 MB NOR Flash
128 MB
HW Watchdog
Battery Backup RTC
Technical Specifications
Web interface status
On
Off
28