Wieland wienet WR-LTE v3 SL User Manual

Industry mobile lte router
Hide thumbs Also See for wienet WR-LTE v3 SL:

Advertisement

Quick Links

wienet WR-LTE v3 SL
Industry mobile LTE router

USER MANUAL

Doc.-No. BA001035
Updatet: 08/2016 (Rev. A)

Advertisement

Table of Contents
loading

Summary of Contents for Wieland wienet WR-LTE v3 SL

  • Page 1: User Manual

    WR-LTE v3 SL Industry mobile LTE router USER MANUAL Doc.-No. BA001035 Updatet: 08/2016 (Rev. A)
  • Page 2 COPYRIGHT This document is copyright-protected. The rights derived from this cop- yright are reserved for Wieland Electric GmbH. Reproduction of this document or parts of this document is only permissible within the lim- its of the statutory provision of the Copyright Act. Any modification or abridgment of the document is prohibited without the express written agreement of Wieland Electric GmbH.
  • Page 3: Table Of Contents

    Technical parameters of GPS ................32 Technical parameters of WiFi ................32 Technical parameters of I/O port ................32 Other technical parameters .................. 32 Recommended Literature ................34 Troubleshooting ..................34 FAQ ......................35 Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 4: About This Manual

    "Danger" or "Warning" are strictly used for cases which present a risk to life or limb. Damage to property only falls into these categories if there is also a risk of personal injury that corresponds to these levels. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 5 If it is in the proximity of TV sets, radio receivers and personal computers, the telephone may cause interference. • It is recommended that you should create an appropriate copy or backup of all the important • settings that are stored in the memory of the device. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 6: Product Disposal Instructions

    At the end of it’s life this product MUST NOT be mixed with other commercial waste for disposal. Check the terms and conditions of your supplier for disposal information. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 7: Router Description

    Examples of possible applications • remote service for machines • mobile office • fleet management • security system • telematic • telemetric • remote monitoring • vending and dispatcher machines Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 8: Usage Of The Router

    3 | Router Description Usage of the Router The router is primarily intended for these four basic situations: I. Access to the Internet from LAN II. Backed up access to the Internet (from LAN) Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 9 3 | Router Description III. Secure networks interconnection or using VPN) IV. Serial Gateway Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 10: Contents Of Package

    • power connector cable • crossover UTP cable, • up to three external antennas, • loose power and I/O connector • clip for the DIN rail, • installation instructions. • USB-Stick with documentation Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 12: Router Design

    Version with RS232/485 & WiFi Basic version with WiFi Basic version Version with SWITCH interface and WiFi Version with SWITCH interface Version with RS485/232 and WiFi Version with RS485/232 interface Version with RS232 interface Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 13: Delivery Identification

    2xSIM, RS232+RS422/485, WIFI WR-LTE v3 SL 5-Port 83.041.0709.1 5x ETH, USB, 2DI, 1DO, 2xSIM WR-LTE v3 SL 5-Port WIFI 83.041.0769.1 5x ETH, USB, 2DI, 1DO, 2xSIM, WIFI Basic dimensions of router box Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 14: Mechanical Dimensions And Mounting Recommendations

    For correct function of the router we recommend to use it in a switch-board with earth-bonding distribu- tion frame for grounding of the power supply, of the router, the data cables and the antenna. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 15: Removing From The Din Rail

    For removing from the DIN rail: 1. lightly push the router upward 2. fold out the top part of the router away from the DIN rail. Removing from the DIN rail Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 16: Description Of The Rear Panel

    Connector for connection of USB devices to the router. Supports Host devices with PL-2303 and FTDI USB/RS232 converters. 6-pin Connector for connection of the binary inputs and output wienet WR-LTE v3 SL front panel Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 17: Status Indication

    The network cable is connected ETH1 Blinking Data transmission ETH2 The network cable is not connected Attention! State indication of WAN LED is updated every 10 seconds. AT TENT I ON Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 18: Power Connector Pwr

    (see figure below). NOTICE : Diversity antenna improves radio fea- tures of the router at low signal strength Diversity antenna improves radio features of the router at low signal strength. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 19: Sim Card Reader

    • After the click, release the card and it will pop out of its slot. • Remove the microSD card and push any other microSD card into the slot until it clicks in place. SD card Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 20: Ethernet Port (Eth0, Eth1 And Eth2)

    Connection of USB connector USB connector 5.8.8 I/O Port Panel socket 6-pin. Pin Signal mark Description Binary input 0 Binary input 0 Binary input 1 Binary input 1 Binary output Binary output I/O connector Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 21: Reset

    RST button on the rear panel. After pressing this button the default configuration is restored and then router reboots (green LED will be on). Note! N OT E For pressing the RST button a narrow screwdriver can be used. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 22 Turn off and then turn on router Disconnect and connect the power, Press the Reboot button in the web configuration Reset Restore default configuration and Press RST button reboot the router Description of reset and restart router Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 23: Interfaces Description

    Receive Data Input RS232 connector Example of a meter connection to the router: State indication of RS232 port: Description of indication Green LED Indicates Receive data Yellow LED Indicates Transmit data Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 24: Rs232-Rs485/422 Interface

    Input/Output TxRx- RS485 A (-) Input/Output Connection of RS422 connector: Signal Description Direction RxD+ RS422 (+) Output RxD- RS422 (-) Output TxD+ RS422 (+) Input TxD- RS422 (-) Input RS485/422 connector Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 25: Switch Interface

    State indication of the port: Description of indication Green LED Selected 100 Mbit/s Selected 10 Mbit/s Yellow LED The network cable is connected Blinking Data transmission The network cable is not connected Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 26: First Use

    APN. The DHCP server will start to assign addresses for devices on the Ethernet port ETH0. Router behavior can be changed via the web interface. This is described in detail in the Configuration manual. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 27: Configuration

    Configuration may be performed only by the user "root" with default password "root". Entering login information After successfully entering login information the user gains access to the router via his internet browser. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 28 6 | First Use Router web interface Note! N OT E A detailed description of the router settings via theWeb interface can be found in the document Config- uration manual for v3 routers. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 30: Technical Parameters

    ETSI EN 300 328 v1.8.1 ETSI EN 301 489-1 v1.9.2, ETSI EN 301 489-12 v2.2.1, IEC 61000-6-2:2005, IEC 61000-6-3:2006 Safety EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013, EN 62311:2008 Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 31: Type Tests And Environmental Conditions

    Supported frequencies: 900 / 1800 / 1900 MHz Supported GPRS/EDGE EGSM 900: Class 4 (33 dBm) power classes GSM 1800/1900: Class 1 (30 dBm) EDGE 900: Class E2 (27 dBm) EDGE 1800/1900: Class E2 (26 dBm) Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 32: Technical Parameters Of Gps

    – 60 V AC/ 300mA – 60 V DC/ 300mA Other technical parameters Other technical parameters CPU power 2 DMIPS per MHz Flash memory 256 MB 512 MB M-RAM 128 kB Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 34: Recommended Literature

    • hand by selection communication rates 10 MB/s in property network cards, • connect router over switch, • start computer only after finalizing the start of the router. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 35: Faq

    SMS message the router will be in this mode up to the next re- start. This behaviour is the same for next all control SMS messages. Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...
  • Page 36 10 | FAQ Wieland Electric GmbH | BA001035 (Rev. A) | 08/2016...

Table of Contents