Power Supply - Wieland wienet LTE LR140 EMEA User Manual

Industrial mobile lte router
Table of Contents

Advertisement

6.4

Power Supply

The pins of power supply are physically connected to the 6-pin terminal block panel socket located
on the left panel. The connection of power supply is shown in Figure 14 and described in Table 8.
Figure 14: Connection of Power Supply
Table 8: Power Supply Pinout
Pen
Signal mark
1
PWR(+)
2
PWR(-)
Required power supply voltage for the router is between +9 V and +48 V DC, see the connection
scheme on Figure 14. Protection against reversed polarity without signaling is built into the router.
For correct operation it is necessary that the power source is able to supply a peak current of 1 A.
Unit has to be supplied by a power supply specified as a Limited Power Source (LPS) or CEC/NEC
Class 2 source of supply.
CAUTION
The metal case of the router is not connected to the negative pole of the power supply (common
pole). If recommended for the installation environment, protect the router by grounding it properly
by the grounding screw on the right panel, see Figure 15.
Figure 15: Position of the Grounding Screw
Wieland Electric GmbH | BA001293 | 02/2023 (Rev. A)
Hardware Functionality
Description
Positive pole of DC supply voltage (+9 ... +48 V DC)
Negative pole of DC supply voltage