Page 1
wienet Router v2 Expansion ports User manual Doc. no. BA000917 Last updated: 08/2021 (Rev. C)
Page 2
Wieland Electric. wienet is a trademark of Wieland Electric. Other product or brand names mentioned in this docu- ment are brand trademarks or registered trademarks of their respective owners. Usage of these names and trademarks by third parties for their own purposes could violate the rights of the owners.
Selecting the current of binary output Expansion port connection Description of protocol XC-CNT MODBUS ASCII Slave Port status Technical specifications Delivery identification Expansion port ETH Description Expansion port connection Port status Technical specifications Delivery identification Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 4
Wi-Fi module description Module configuration 8.2.1 Wi-Fi status 8.2.2 Wi-Fi configuration Port status Technical specifications Delivery identification Expansion port SD SD description SWITCH Compatibility with Wieland routers Port status Technical specifications Delivery identification Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 5
Table of contents Installing a router in a metal housing Maintenance Product disposal Service and Support Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The installation instructions accompanying the product is downloadable in the electronic catalog of Wieland. Be sure to always use the information provided in the current version of this installation manual. The version and revision level can be seen in the title page and the footer.
Refer to notes for special features of a device. NOTICE Instructions also tell you about a potentially harmful situation. If it is not avoided, the system can be damaged or something in their environment. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Qualified is, who: • has an appropriate technical training and • has access to the wienet VPN router installation manuals, and this has been read and under- stood. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
• Use only the original Wieland accessories. Thus, you will prevent possible health risks and dam- age to the devices and ensure compliance with all relevant provisions. Unauthorized adjust- ments or use of unapproved accessories may result in damage to the expansion port and breach of applicable laws.
Alarm is possible send after time after which upper limit must be overrun. In case that it isn't any change on input, it is possible to define time after which the value on input will zero. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
20 mA. When jumper J4 is not mounted, electric value is 8 μA. If current value is 20 mA, CNT has higher consumption, also it has higher resistance to industrial noise. Figure 1: CNT board Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Typical connection of the router measuring circuits: Figure 3: Connection of the router measuring circuits The router does not support modifying any signals of the CNT port, for example logical functions. NOTICE Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Minimal frequency CNT2 0x0605 Maximal frequency CNT2 0x0F00 0x0000 always 0x0F01 0x0000 always 0x0F02 Upper 16 bits of seconds number from 1.1.1970 0x0F03 Lower 16 bits of seconds number from 1.1.1970 Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 14
1. log – average frequency CNT2 0x1012 1. log – minimal frequency CNT2 0x1013 1. log – maximal frequency CNT2 0x1100 2. log 0x1200 3. log … … 0xEF00 224. log Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
CNT expansion port Sleeping mode Controlled Delivery identification Trade name Type name Power supply XC-CNT XC-CNT Internal or external supply Figure 4: Example of expansion port CNT label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The expansion port ETH is created as expansion port which enables to use of the next hardware in- ter-face of Wieland modems for next signal processing. This interface is physical connected on RJ45 connector on appropriate modem. The expansion port ETH is internal supplies from appropriate modem.
(IEEE 802.3) Max. total cable length (300 Bd, 200 nF/km) 100 m Delivery identification Trade name Type name Power supply XC-ETH XC-ETH Internal supply Figure 7: Example of expansion port ETH label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The expansion port MBUSD is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. The expansion port MBUS is equipment of a MASTER type. This interface is physically connected on RJ45 connector on appropriate router. The expansion port MBUSD is internal supplies from appropriate router.
60 mA Overload detection 100 mA Short circuit strength Permanent Bus voltage mark 36 … 43 V Bus voltage space 24 … 31 V Max. total cable length (300Bd, 200nF/km) 1000 m Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Expansion port MBUSD Delivery identification Trade name Type name Power supply XC-MBUS XC-MBUS External supply Figure 11: Example of expansion port MBUSD label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The expansion port RS232 is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. This interface is physically connected to the RJ45 connector on the appropriate router. The expansion port RS232 is internal supplies from ap- propriate router.
±30 V Max. total cable length (300 Bd, 200 nF/km) 20 m Delivery identification Trade name Type name Power supply XC-RS232 XC-232 Internal supply Figure 16: Example of expansion port RS232 label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The expansion port RS485/RS422 is created as an expansion board which enables the use of the next hardware interface of Wieland modems or routers for next signal processing. This interface is physi- cally connected on RJ45 connector on appropriate modem or routers.
Figure 21: Circuit equipment with a router with data cable length more than 10 m NOTICE With an RS485 data cable longer than 10 m it is necessary to use overvoltage protection on the router side! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Figure 24: Circuit equipment with a router with data cable length more than 10 m NOTICE With an RS422 data cable longer than 10 m it is necessary to use overvoltage protection on the router side! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Permanent Max. total cable length (300Bd, 200nF/km) 1200 m Delivery identification Trade name Type name Power supply XC-RS485/422 XC-485-422 Internal or external supply Figure 25: Example of expansion port RS485 label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
The expansion port Wi-Fi is created as an addition of router desk, allowing the use of wireless inter- face in Wieland v2 routers. This expansion port is provided as an internal part of the router. Wi-Fi module supports AP (Access Point) function. This module allows you to scan the neighboring networks.
Table 3: Status information about Wi-Fi client Item Description MAC address of associated station STA's unique AID (1 … 2007) or 0 if not yet assigned. Figure 27: Wi-Fi AP status Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 31
Last response time of access point (AP). SSID Identifier for access point (AP). Supported rates Supported rates of access point (AP). DS Parameter set The channel on which broadcast access point (AP). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 32
WiFi AP activity is indicated in rows starting “hostapd” or “dhcpd-wifi”. Press the Save button to save the system log to the computer. Figure 31: System Log Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Type of WEP key for WEP encryption. • ASCII – WEP key in ASCII format • HEX – WEP key in hexadecimal format WEP Default Key This item specifies the default WEP key. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 34
• Verbose debugging – The highest level of communicativeness. • Debugging • Informational – Default level of communicativeness that is used for writing standard events. • Notification • Warning – The lowest level of communicativeness. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 35
If this option is checked, dynamic DHCP server is enabled. IP Pool Start Start IP addresses space. IP Pool End End IP addresses space. Lease Time Time in seconds that the client can use IP address. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
15 dBm Internal antenna impedance 50 Ohm Frequency band 2.4 GHz Delivery identification Trade name Type name Power supply XC-WIFI XC-WIFI Internal supply Figure 34: Example of expansion port Wi-Fi label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
(expands existing memory). In the opposite case (the item is not checked), SD port can be used as a USB flash drive (for connecting the router to the PC use A-A type of USB cable). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
In practice, this means that industrial card can be used throughout the range of operating tempera- ture of SD expansion port. Another advantage is the increased resistance to falls and vibrations. Delivery identification Trade name Type name Figure 38: Example of expansion port Wi-Fi label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 39
Connect the expansion port PORT2 (pos. 3) to the connector J3 (see figure above) on the rout- er's motherboard B-RB-v2 (pos. 1) from the top. Attach each expansion port to the motherboard with three spacers for each (pos. 10). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 40
Close the rear panel (pos. 6) by screwing the four screws (pos. 11) back in. Attach the label that is included in the delivery to the side of the router (see figure below). Figure 40: Router with label for expansion ports Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 41
The SIM-card must be handled as carefully as a credit card. Do not bend or scratch the SIM card. Do not expose the SIM card to static electricity. • During cleaning of the router, do not use aggressive chemicals, solvents or abrasive cleaners! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 42
The device contains the battery. Remove the battery from the device before disposal. The battery in the device needs to be disposed apart accordingly. Check the terms and conditions of your supplier for disposal information. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
Page 43
Admission: Wieland Electric hereby declares that the router described in this user manual fits all basic demands of directive 2014/53/EU (R&TTE). Router fits values of coefficient SAR defined by association ICNIRP and values of "About protection of health before non-ionized radiation".