  • Page 1 wienet Router v2 Expansion ports User manual Doc. no. BA000917 Last updated: 08/2021 (Rev. C)
  • Page 2 Wieland Electric. wienet is a trademark of Wieland Electric. Other product or brand names mentioned in this docu- ment are brand trademarks or registered trademarks of their respective owners. Usage of these names and trademarks by third parties for their own purposes could violate the rights of the owners.
  • Page 3: Table Of Contents

    Selecting the current of binary output Expansion port connection Description of protocol XC-CNT MODBUS ASCII Slave Port status Technical specifications Delivery identification Expansion port ETH Description Expansion port connection Port status Technical specifications Delivery identification Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 4 Wi-Fi module description Module configuration 8.2.1 Wi-Fi status 8.2.2 Wi-Fi configuration Port status Technical specifications Delivery identification Expansion port SD SD description SWITCH Compatibility with Wieland routers Port status Technical specifications Delivery identification Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 5 Table of contents Installing a router in a metal housing Maintenance Product disposal Service and Support Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 6: About This Document

    The installation instructions accompanying the product is downloadable in the electronic catalog of Wieland. Be sure to always use the information provided in the current version of this installation manual. The version and revision level can be seen in the title page and the footer.
  • Page 7: Symbols And Notations

    Refer to notes for special features of a device. NOTICE Instructions also tell you about a potentially harmful situation. If it is not avoided, the system can be damaged or something in their environment. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 8: Safety Instructions

    Qualified is, who: • has an appropriate technical training and • has access to the wienet VPN router installation manuals, and this has been read and under- stood. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 9: Intended Use

    • Use only the original Wieland accessories. Thus, you will prevent possible health risks and dam- age to the devices and ensure compliance with all relevant provisions. Unauthorized adjust- ments or use of unapproved accessories may result in damage to the expansion port and breach of applicable laws.
  • Page 10: Cnt Expansion Port

    Alarm is possible send after time after which upper limit must be overrun. In case that it isn't any change on input, it is possible to define time after which the value on input will zero. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 11: Binary Output

    20 mA. When jumper J4 is not mounted, electric value is 8 μA. If current value is 20 mA, CNT has higher consumption, also it has higher resistance to industrial noise. Figure 1: CNT board Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 12: Expansion Port Connection

    Typical connection of the router measuring circuits: Figure 3: Connection of the router measuring circuits The router does not support modifying any signals of the CNT port, for example logical functions. NOTICE Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 13: Description Of Protocol Xc-Cnt Modbus Ascii Slave

    Minimal frequency CNT2 0x0605 Maximal frequency CNT2 0x0F00 0x0000 always 0x0F01 0x0000 always 0x0F02 Upper 16 bits of seconds number from 1.1.1970 0x0F03 Lower 16 bits of seconds number from 1.1.1970 Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 14 1. log – average frequency CNT2 0x1012 1. log – minimal frequency CNT2 0x1013 1. log – maximal frequency CNT2 0x1100 2. log 0x1200 3. log … … 0xEF00 224. log Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 15 AN2 – multiplicative constant (with sign) 0xF402 AN2 – additive constant (with sign) 0xF403 AN2 – hysteresis value (with sign) 0xF404 AN2 – lower limit (with sign) 0xF405 AN2 – upper limit (with sign) Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 16: Port Status

    0 … 20 mA, 100 Ohms 2× binary inputs Reed contact with J4 - 20mA without J4 8μA 1× output (open collector) 30 V / 100 mA Others Voltage resistance Permanent Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 17: Delivery Identification

    CNT expansion port Sleeping mode Controlled Delivery identification Trade name Type name Power supply XC-CNT XC-CNT Internal or external supply Figure 4: Example of expansion port CNT label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 18: Expansion Port Eth

    The expansion port ETH is created as expansion port which enables to use of the next hardware in- ter-face of Wieland modems for next signal processing. This interface is physical connected on RJ45 connector on appropriate modem. The expansion port ETH is internal supplies from appropriate modem.
  • Page 19: Port Status

    (IEEE 802.3) Max. total cable length (300 Bd, 200 nF/km) 100 m Delivery identification Trade name Type name Power supply XC-ETH XC-ETH Internal supply Figure 7: Example of expansion port ETH label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 20: Expansion Port Mbusd

    The expansion port MBUSD is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. The expansion port MBUS is equipment of a MASTER type. This interface is physically connected on RJ45 connector on appropriate router. The expansion port MBUSD is internal supplies from appropriate router.
  • Page 21: Overload Detection

    60 mA Overload detection 100 mA Short circuit strength Permanent Bus voltage mark 36 … 43 V Bus voltage space 24 … 31 V Max. total cable length (300Bd, 200nF/km) 1000 m Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 22: Delivery Identification

    Expansion port MBUSD Delivery identification Trade name Type name Power supply XC-MBUS XC-MBUS External supply Figure 11: Example of expansion port MBUSD label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 23: Expansion Port Rs232

    The expansion port RS232 is created as expansion port which enables to use of the next hardware interface of Wieland routers for next signal processing. This interface is physically connected to the RJ45 connector on the appropriate router. The expansion port RS232 is internal supplies from ap- propriate router.
  • Page 24: Port Status

    ±30 V Max. total cable length (300 Bd, 200 nF/km) 20 m Delivery identification Trade name Type name Power supply XC-RS232 XC-232 Internal supply Figure 16: Example of expansion port RS232 label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 25: Expansion Port Rs485/Rs422

    The expansion port RS485/RS422 is created as an expansion board which enables the use of the next hardware interface of Wieland modems or routers for next signal processing. This interface is physi- cally connected on RJ45 connector on appropriate modem or routers.
  • Page 26: Expansion Port Connection Rs485

    Figure 21: Circuit equipment with a router with data cable length more than 10 m NOTICE With an RS485 data cable longer than 10 m it is necessary to use overvoltage protection on the router side! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 27: Expansion Port Connection Rs422

    Figure 24: Circuit equipment with a router with data cable length more than 10 m NOTICE With an RS422 data cable longer than 10 m it is necessary to use overvoltage protection on the router side! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 28: Port Status

    Permanent Max. total cable length (300Bd, 200nF/km) 1200 m Delivery identification Trade name Type name Power supply XC-RS485/422 XC-485-422 Internal or external supply Figure 25: Example of expansion port RS485 label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 29: Wi-Fi Module

    The expansion port Wi-Fi is created as an addition of router desk, allowing the use of wireless inter- face in Wieland v2 routers. This expansion port is provided as an internal part of the router. Wi-Fi module supports AP (Access Point) function. This module allows you to scan the neighboring networks.
  • Page 30: Module Configuration

    Table 3: Status information about Wi-Fi client Item Description MAC address of associated station STA's unique AID (1 … 2007) or 0 if not yet assigned. Figure 27: Wi-Fi AP status Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 31 Last response time of access point (AP). SSID Identifier for access point (AP). Supported rates Supported rates of access point (AP). DS Parameter set The channel on which broadcast access point (AP). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 32 WiFi AP activity is indicated in rows starting “hostapd” or “dhcpd-wifi”. Press the Save button to save the system log to the computer. Figure 31: System Log Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 33: Wi-Fi Configuration

    Type of WEP key for WEP encryption. • ASCII – WEP key in ASCII format • HEX – WEP key in hexadecimal format WEP Default Key This item specifies the default WEP key. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 34 • Verbose debugging – The highest level of communicativeness. • Debugging • Informational – Default level of communicativeness that is used for writing standard events. • Notification • Warning – The lowest level of communicativeness. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 35 If this option is checked, dynamic DHCP server is enabled. IP Pool Start Start IP addresses space. IP Pool End End IP addresses space. Lease Time Time in seconds that the client can use IP address. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 36: Port Status

    15 dBm Internal antenna impedance 50 Ohm Frequency band 2.4 GHz Delivery identification Trade name Type name Power supply XC-WIFI XC-WIFI Internal supply Figure 34: Example of expansion port Wi-Fi label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 37: Expansion Port Sd

    (expands existing memory). In the opposite case (the item is not checked), SD port can be used as a USB flash drive (for connecting the router to the PC use A-A type of USB cable). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 38: Compatibility With Wieland Routers

    In practice, this means that industrial card can be used throughout the range of operating tempera- ture of SD expansion port. Another advantage is the increased resistance to falls and vibrations. Delivery identification Trade name Type name Figure 38: Example of expansion port Wi-Fi label Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 39  Connect the expansion port PORT2 (pos. 3) to the connector J3 (see figure above) on the rout- er's motherboard B-RB-v2 (pos. 1) from the top.  Attach each expansion port to the motherboard with three spacers for each (pos. 10). Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 40  Close the rear panel (pos. 6) by screwing the four screws (pos. 11) back in.  Attach the label that is included in the delivery to the side of the router (see figure below). Figure 40: Router with label for expansion ports Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 41 The SIM-card must be handled as carefully as a credit card. Do not bend or scratch the SIM card. Do not expose the SIM card to static electricity. • During cleaning of the router, do not use aggressive chemicals, solvents or abrasive cleaners! Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 42 The device contains the battery. Remove the battery from the device before disposal. The battery in the device needs to be disposed apart accordingly. Check the terms and conditions of your supplier for disposal information. Wieland Electric GmbH | BA000917 | 08/2021 (Rev. C)
  • Page 43 Admission: Wieland Electric hereby declares that the router described in this user manual fits all basic demands of directive 2014/53/EU (R&TTE). Router fits values of coefficient SAR defined by association ICNIRP and values of "About protection of health before non-ionized radiation".
  • Page 44 Wieland Electric GmbH Brennerstraße 10 – 14 DE-96052 Bamberg Tel +49 951 9324-0 Fax +49 951 9324-198 info@wieland-electric.com www.wieland-electric.com...