3. Attach the flange mount adapter or the 48.3 mm round tube with the two M8 threaded
pins. Observe the appropriate torque:
– Siemens flange mount adapter: 8 Nm
– 48.3 mm steel round tube 8 Nm
– 48.3 mm aluminum round tube: 5 Nm
4. When you are using an adapter plate from a Siemens VESA adapter set, attach the adapter
plate to the support arm with 4 M6x12 screws.
When you are using another adapter plate matching the Siemens flange mount adapter,
attach the adapter plate to the support arm with the supplied mounting material.
When tightening the screws, observe the torque that is specified for the support arm.
5. Insert all connecting cables through the opening of the flange mount adapter or 48.3 mm
round tube into the connection compartment of the PRO device. Make sure that the
connection cables are not damaged.
6. When you are using an adapter plate from a Siemens VESA adapter set, attach the flange
mount adapter with 4 M6 screws, 16 mm to 20 mm long to the load-bearing system from
below.
When you are not using an adapter plate or a different adapter plate, attach the flange
mount adapter with 4 M6 screws to the load-bearing system from below. The screw
length depends on the specifications for the load-bearing system and must be at least
16 mm to securely fasten the flange mount adapter.
The screws are not included in the product package of the PRO device. Observe the torque
that is specified for the support arm. Make sure that the connection cables are not
crushed.
7. Connect all cables, follow the instructions in section "Connecting the device (Page 56)".
8. Fasten the terminal compartment cover to the device with the 2 supplied screws, torque
1.5 Nm. Ensure that the seal is sitting correctly.
9. Attach the lower cover supplied with the PRO device with 4 M4x12 screws, torque 1.5 Nm.
Alternatively, you can extend the PRO device by adding an Extension Unit at the bottom.
Observe the associated documentation.