Type of condition
Temperature built-in de-
vices,
Mounting in portrait for-
mat
Temperature PRO devices
1
Temperature Transceiv-
er Unit
Air pressure, operating
elevation
Relative humidity
Pollutant concentration
1
2
Observe the information in section "Notes on use (Page 28)" and for IFPs the information on
the mounting positions:
• Permitted mounting positions for built-in devices (Page 34)
• Permitted mounting positions for PRO devices (Page 39)
Note
All other system components connected to the device, such as the power supply, must also
be suited to the respective operating conditions.
7.5
Information on insulation tests, protection class and degree of
protection
Insulation test
The insulation strength is demonstrated in the type test with the following test voltages in
accordance with IEC 61010-2-201:
Circuit
Rated voltage U
Ethernet socket
1
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE

7.5 Information on insulation tests, protection class and degree of protection

Mounting position
Vertical
Inclined, maximum inclination
35°
Vertical
Inclined, maximum inclination
45°
vertical, interfaces facing down-
ward
1140 ... 795 hPa, corresponds to an elevation of -1000 ... 2000 m
10 ... 90 %, no condensation
According to ANSI/ISA-71.04-2013 severity level G3
Only mounting in the standard mounting position is permitted for PRO devices
Built-in devices: No condensation on the rear of the device,
PRO devices: No condensation inside the enclosure,
Transceiver Unit No condensation all-round
24 V
e
1
Check applies to interface X1 Ethernet, not to X71 Ext-Link
2
Insulation tested with (type test)
707 V DC to other circuits / to ground
1500 V AC
Technical information
Permitted range
0 ... 40 °C
0 ... 35 °C
0 ... 45 °C
0 ... 45 °C
0 ... 50 °C