Technical Specifications Of The Transceiver Unit - Siemens SIMATIC V2 Operating Instructions Manual

Industrial flat panels
Table of Contents

Advertisement

Technical information

7.9 Technical specifications of the Transceiver Unit

IFP V2 devices
USB Type A
1
USB Type B, host
Ext-Link
2
Ethernet
USB type A, maximum load 500 mA, equivalent to USB standard 2.0
1
Proprietary interface for internal communication
2
DC power supply
IFP V2 devices
Rated voltage
Permitted voltage range
Mains and voltage buffering time
Rated current at 24 V DC, without
loads
Rated current, load-dependent
Power consumption
1
Inrush current I
t
2
Maximum permitted transients
Minimum time between two tran-
sients
Internal protection
The power loss generally corresponds to the specified value for power consumption.
1
7.9
Technical specifications of the Transceiver Unit
Weight
Weight of the Transceiver Unit including fixing accessories
Interfaces
DisplayPort
USB Type B, host
Ext Link
1
126
Standard versions
No
12"
0.65 A
0.5 ... 1.0 A
15.6 W
1
Proprietary interface for internal communication
Extended versions and PRO devices
Yes, USB hub
Yes
No
15"
19"
24 V DC
+19.2 V ... +28.8 V
1 ms
1 A
1.2 A
0.8 ... 1.3 A
1.0 ... 1.5 A
24 W
29 W
0.5 A
35 V (500 ms)
Electronic
Ethernet Monitors
Yes
22"
1 A
0.8 ... 1.3 A
24 W
s
2
50 s
0.35 kg
Yes
Yes
Yes
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE
No
Yes
24"
1.5 A
1.3 ... 1.9 A
36 W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic ifp v2Simatic ifp v2 proSimatic ifp v2 eth

Table of Contents