Command Sets For Telnet Console; Dconfig; Default; Diag - Dynamix HP HP-51M User Manual

Homepna3.1 coax mdu master bridge
Table of Contents

Advertisement

Note that Telnet connection will be terminated automatically if the telnet client doesn't input any command for 5
minutes; i.e. the console idle timer is 10 minutes (600 Sec).

Command Sets for Telnet Console

The following table lists all commands for Telnet console. The third column 'Description' explains what happen
when you run the 'Commands' in the first column and also explains the versatile options of the second column
'Arguments'.
Some common formats for arguments are:
<mac>
MAC address, format in
<ip>
IPv4 address, format in
<mask>,
<interface>
Network interface name, 'eth0' for LAN1/LAN2 interface, 'hpna0' for HCNA interface.
<fid>
Flash ROM file id represented different firmware/driver,
'n=0': System bootcode (bootloader)
'n=1': System firmware (OS)
'n=2': Master HCNA driver (3110)
'n=3': 3010 EP HCNA driver
'n=5': 3110 EP HCNA driver
'n=10': 3010 EP diagnosis utility
'n=11': 3110 EP diagnosis utility
Only lowercase letter can be accepted. Typing commands followed by pressing 'ENTER' will execute the command.
Run any command with '-h' argument will show you the usage
Commands

dconfig

default

-t
<mac>
-r
<mac>

diag

'nn-nn-nn-nn-nn-nn
'nnn.nnn.nnn.nnn
<default gateway>
Arguments
[ ]
is optional
Dump all configurations/settings.
Reset all settings to factory default, except Password.
On-line EP connection diagnosis.
-t: downstream SNR diagnosis(from Master to EP)
-r: upstream SNR diagnosis(from EP to Master)
<mac>: EP MAC
DYNAMIX HP-51M Coax MDU Master Bridge User's Guide
where nn=00~FF'. As '00-01-40-13-03-36'.
where n=0~9'. As '192.168.1.1'. Also applicable for
'n
where n=0~12',
Description
<mac>
to be diagnosed