Operation; Generator Location; Grounding - Westinghouse WGen20000c User Manual

Table of Contents

Advertisement

Available languages

Available languages

OPERATION

OPERATION

GENERATOR LOCATION

Read and understand all safety information before starting
the generator.
NEVER operate the generator inside any building, including
garages, basements, crawlspaces, sheds, enclosure, or
compartment, including the generator compartment of a
recreational vehicle.
Electrocution hazard. NEVER use the generator in
a location that is wet or damp. NEVER expose the
generator to rain, snow, water spray, or standing water
while in use. Protect the generator from all hazardous
weather conditions. Moisture or ice can cause a short
circuit or other malfunction in the electrical circuit. Using
a generator or electrical appliance in wet conditions,
such as rain or snow, or near a pool or sprinkler system,
or when your hands are wet, could result in electrocution
Fire hazard. Only operate the generator on a solid, level
surface. Operating the generator on a surface with loose
material such as sand or grass clippings can cause debris
to be ingested by the generator that could block cooling
vents or the air intake system. Allow the generator to
cool for 30 minutes before transport or storage.
The generator should be on a flat, level surface at all times
(Even while not in operation). The generator must have
at least 5 ft. (1.5 m) of clearance from all combustible
material.
DO NOT operate the generator in the back of a SUV,
camper, trailer, truck bed (regular, flat, or otherwise), under
stairs, next to walls or buildings, or in any other location
that will not allow for adequate cooling of the generator
and/or the muffler. DO NOT contain generators during
operation.
16 | Westinghouse Outdoor Power Equipment, LLC
Asphyxiation hazard. Place the generator in a well-
ventilated area. DO NOT place the generator near vents
or intakes where exhaust fumes could be drawn into
occupied or confined spaces. Carefully consider wind
and air currents when positioning the generator.

GROUNDING

Shock hazard. Failure to properly ground the generator
can result in electric shock.
Only use grounded 3-prong extension cords, tools, and
appliances, or double-insulated tools and appliances.
The generator neutral is bonded to the frame. There is a
permanent conductor between the generator (stator wire)
and the frame. If this generator will be used only with cord
and plug equipment connected to the receptacles mounted
on the generator, National Electric Code does not require
that the unit be grounded. However, other methods of
using the generator may require grounding to reduce the
risk of shock or electrocution.
Before using the ground terminal, consult a qualified
electrician, electrical inspector, or local agency having
jurisdiction for local codes or ordinances that apply to the
intended use of the generator.
DISCONNECTING THE BONDED NEUTRAL
The bonded neutral should only be removed under specific
circumstances. Consult a qualified electrician to determine
if circumstances require disconnecting the bonded neutral.
1. Remove the alternator cover.
2. Remove the white bonded jumper wire from the ground
bolt and unmarked terminal connection. Reinstall the
bolts and tighten securely.
NOTICE

Advertisement

Table of Contents
loading

Table of Contents