Operating, servicing and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, do not idle the engine except as necessary, service your equipment in a well-ventilated area and wear gloves or wash your hands frequently when servicing your equipment. For more information go to www.P65Warnings.ca.gov.
This manual contains important instructions for operating this generator. For your safety and the safety of others, be sure to read this manual thoroughly before operating the generator. Failure to properly follow all instructions and precautions can cause you and others to be seriously hurt or killed.
Model Number | Running Watts | Peak Watts | Gasoline Tank Size (G) | Rated Speed (RPM) | Ignition Type | Spark plug | Engine Disp (cc) | Stroke X Bore | Oil Capacity (L) | Oil Type | Fuel Type |
WGen3600DF | Gas: 3600 Propane: 3240 | Gas: 4650 Propane: 4180 | 4 Gallons | 3600 | TCI | F7TC | 212cc | 55X70 | .6 L | 10W30 | Gasoline |
The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Be certain that the meanings of these alerts are known to all who work on or near the equipment.
This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.
Indicates a hazardous situation which, if not avoided, will result in death or serious injury. |
Indicates a hazardous situation which, if not avoided, could result in death or serious injury. |
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. |
NOTICE |
Indicates a situation which can cause damage to the generator, personal property and/or the environment, or cause the equipment to operate improperly. |
NOTE: Indicates a procedure, practice or condition that should be followed in order for the generator to function in the manner intended.
Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. | |
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents. | |
Voltage produced by the generator could result in death or serious injury.
| |
Gasoline, gasoline vapors & liquid petroleum gas (LPG) are extremely flammable and explosive under certain conditions.
| |
Never operate the generator if powered items overheat, electrical output drops, there is sparking, flames or smoke coming from the generator, or if the receptacles are damaged. | |
Never use the generator to power medical support equipment. | |
Always remove any tools or other service equipment used during maintenance from the generator before operating. | |
NOTICE | |
Never modify the generator. Never operate the generator if it vibrates at high levels, if engine speed changes greatly or if the engine misfires often. Always disconnect tools or appliances from the generator before starting. |
Gasoline and liquid petroleum gas (LPG) are highly explosive and flammable. Explosions and fire can cause severe burns or death. |
Never use a gas container, LPG connector hose, LPG tank or any other fuel item that appears to be damaged. |
Only use approved LPG tanks with OPD (overfilling prevention device) valve. Always keep the tank in a vertical position with the valve on top and installed at ground level on a flat surface. Do not allow tanks to be around any heat source and make sure it is not exposed to the sun, rain and dust. When transporting and storing, turn off the tank valve and fuel valve, and disconnect the tank. Make sure to always cover the generator and tank outlet with protective plastic caps. |
Do not allow children to tamper or play with the propane tank or hose connections. |
If there is a strong smell of propane while operating the generator close the valve on the propane tank immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. Do not smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found contact a qualified technician to inspect and repair the LPG system before using the generator. |
Always have assistance when lifting the generator. The generator is heavy; lifting it could cause bodily harm. |
Avoid cutting on or near staples to prevent personal injury. |
Tools required – box cutter or similar device.
Owners Manual
Quick Start Guide/Maintenance Schedule
Remote Start Key Fob (1)
LPG Hose (1)
.6 Liter Bottle of SAE 10W30 Oil (1)
Spark Plug Socket Wrench (1)
Wheel Kit Accessories Box
Funnel (1)
Open the Wheel Kit Accessories box and verify the contents against the list right. If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.
Figure 1 - Wheel and Feet Kit Hardware
BEFORE ASSEMBLING THE GENERATOR, REVIEW THE SAFETY SECTION.
Never lift the generator without assistance. The generator is heavy and lifting without assistance could result in personal injury. |
Never use the handles as a lifting point to support the entire weight of the generator. Only use the handles to move the generator by lifting the handles and using the wheels to move the generator. |
Use caution when collapsing the handles. Hands and fingers could get caught and pinched. |
NOTICE |
Assembling the generator will require lifting the unit on one side. Make sure all engine oil and fuel are drained from the unit prior to assembling. Once assembled, the wheel kit is not intended for on- road use. The wheel kit is designed for use on this generator only. |
To avoid electric shock:
|
NOTICE |
The electric start generator is equipped with a battery charging feature. Once the engine is running, a small charge is supplied to the battery via the battery cables and will slowly recharge the battery. |
NOTICE |
Even if you do not plan on using the electric start feature it is recommended that you install the battery to complete the circuit in order for the automatic choke mechanism to work properly. |
BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION.
Before starting the generator, avoid exhaust and location hazards by verifying:
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. | |
NEVER use inside a home or garage, EVEN IF doors and windows are open. | Only use OUTSIDE and far away from windows, doors, and vents. |
Avoid other generator hazards, READ MANUAL BEFORE USE. | |
Always operate the generator on a level surface. Placing the generator on non level surfaces can cause the generator to tip over, causing fuel and oil to spill. Spilled fuel can ignite if it comes in contact with an ignition source such as a very hot surface. | |
Do not operate a device plugged into the USB ports. Prolonged exposure to engine exhaust can cause serious injury or death. While charging a device do not place on the exhaust side of the generator. Extreme heat caused by exhaust can damage the device, and cause a potential fire hazard. | |
NOTICE | |
Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could:
|
Never operate your generator outdoors during rain, snow or any combination of weather conditions that could lead to moisture collecting on, in or around the generator.
Always operate the generator on a dry surface free of any moisture.
Make sure the generator has no connected loads before starting it. To ensure there are no connected loads, unplug any electrical extension cords that are plugged into the control panel receptacles.
NOTICE |
Starting the generator with loads already applied to it could result in damage to any appliance being powered off the generator during the brief start-up period. |
The National Electric Code (NEC), as well as many local electrical codes, may require the generator to be connected to earth ground. The most common application that requires a ground rod is when you are using the generator as a separately derived system to provide back up power to your house. Typically this is when a transfer switch has a switched neutral.
As the generator application has many variables that cannot be determined by the manufacturer of the generator, a licensed electrician will need to determine if a grounding rod is needed.
If a licensed electrician has determined the application requires a ground rod, make sure it is connected to earth ground by connecting the ground terminal on the control panel to earth ground using copper wire (minimum 10 AWG). Consult a qualified electrician for local grounding requirements.
Be sure the generator is properly connected to earth ground before operating. The generator must be grounded to prevent electrical shock due to faulty appliances. |
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000ft of increased altitude from sea level. This is a natural occurrence and cannot be adjusted by engine. Increased exhaust emissions can also result due to increased fuel mixture. Other issues include hard starting, increased fuel consumption and spark plug fouling. Contact our service team 1-855-944-3571 for altitude part kits.
High Altitude Carburetor Kit Part Number: 140543
High Altitude DF Regulator Part Number: 140560
Note: You must purchase the Dual Fuel Regulator along with carburetor kit on the WGen3600DF
Westinghouse Portable Power assumes no responsibility for the content within this table. The use of this table is the responsibility of the user only. This table is intended for reference only. The results produced by using this table are not guaranteed to be correct or applicable in all situations as the type and construction of cords are highly variable. Always check with local regulations and a licensed electrician prior to installing or connecting an electrical appliance
Use the extension cord chart to determine the size of the conductor for extension cord applications. Determine the distance of the generator to the appliance on the top line of the chart. Then select the rated amperage of the generator on the left side of the chart. Where the two meet is the size of the conductor required for the application.
The WCG25 power cord is connected to the generator at the 120/240 plug. The opposite end of the power cord is a fan tail receptacle with 2 green receptacles and 2 red receptacles. Each receptacle is rated at 120 volts AC. To balance the load on the generator's alternator, use the red and green identifiers on the fan tail receptacle. To keep the load balanced, connect the loads so that both color receptacles are used. An example is one in red and one in green. Do not connect 2 in red and none in green, or 2 in green and none in red. If only one color receptacle is used with multiple loads, the alternator may experience an unbalanced load, causing undue vibration to generator.
Figure 6 - WCG25 Extension Cord
BEFORE ADDING/CHECKING ENGINE FLUIDS AND FUEL, REVIEW SAFETY SECTION.
Filling the fuel tank with gasoline while the generator is running can cause gasoline to leak and come in contact with hot surfaces that can ignite the gasoline. |
Before starting the generator, always check:
It is not safe to add gasoline to the fuel tank or engine oil to the engine while the engine is running or the engine and muffler are hot.
Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick. |
The unit as shipped does not contain oil in the engine. You must add engine oil before starting the generator for the first time. See Checking Engine Oil and Adding Engine Oil for instructions on checking engine oil level and the procedure for adding engine oil.
NOTICE |
The engine does not contain engine oil as shipped. Attempting to start the engine can damage engine components. The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage. |
NOTICE |
During the first five hours of operating the generator make sure to not exceed 50% of the rated running watts until the unit is broken in properly. Make sure to vary to load occasionally to allow stator windings to heat and cool. Adjusting the load will also help seat piston rings. Check oil more often during the first couple times of operating the generator. |
NOTICE |
Weather will affect engine oil performance. Change the type of engine oil used based on weather conditions to suit the engine needs. |
NOTICE |
The key fob included with the generator should come already paired with the unit. If it does not you can follow the directions below to reconnect. If your unit was shipped without a key fob please contact our customer support team. |
Always make sure the area around the generator is clear of bystanders before using the remote start to start the generator. |
The generator can be started remotely from up to a maximum of 109 yards (100 M) away using the remote start key fob with new, fully charged batteries in the key fob. As the batteries' state of charge in the key fob reduces, the distance to start the generator will also reduce.
Before the generator can be started, an initial start-up procedure must be performed so the generator and the key fob recognize each other. If the key fob is replaced, you will need to go through this procedure with the new fob.
BEFORE ADDING GAS TO THE TANK PLEASE REVIEW FUEL SAFETY SECTION
Never refuel the generator while the engine is running. |
Always turn the engine off and allow the generator to cool before refueling. |
Only use gasoline that meets the following requirements:
Follow the steps below to fill the fuel tank:
Avoid prolonged breathing of gasoline vapors. |
BEFORE CONNECTING PROPANE TANK TO THE GENERATOR PLEASE REVIEW FUEL SAFETY SECTION
NOTICE |
|
Do not start generator if you smell propane. This may result in explosion hazard. Do not use provided LPG hose for any other appliances. Always turn off the propane tank and disconnect LPG hose when not in use. |
BEFORE STARTING THE GENERATOR, REVIEW SAFETY SECTION.
Before attempting to start the generator, verify the following:
Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. |
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only operate the generator outside and away from windows, doors and vents. |
NOTICE |
The engine is equipped with a low oil shutdown switch. If the oil level becomes low, the engine may shut down and not start until the oil is filled to the proper level. Poor oil quality may interfere with the operation of the low oil shutdown switch. The owner of the generator is responsible to ensure the proper oil level is maintained during the operation of the generator. Failure to maintain the proper oil level can result in engine damage. |
NOTICE |
When operating on LPG it is common for frost to form on the tank and regulators. This is not an indication of a problem. The amount of frost that forms can be affected by the size of the container, the amount of fuel being used, the humidity of the air and other operating conditions. In standard use this frost may reduce flow of gas and lower performance. If frost becomes an issue try exchanging fuel tanks to allow the first tank to warm up. You can also temporarily warm the tank up by pouring warm water over the top of the propane tank. |
BEFORE ADDING GAS TO THE TANK PLEASE REVIEW FUEL SAFETY SECTION
The below assumes that the propane fuel line is already attached to the generator securely and safely.
While the unit is running simply turn the FUEL SELECTOR knob to the desired fuel source. If you want to switch from gasoline to propane make sure the propane tank valve is open before you switch. When you move from propane to gasoline shut the propane valve after you have switched to gas.
NOTICE |
If you do not plan on operating the unit on propane do not leave the propane tank valve open. When starting on propane the engine may run rough for a few seconds while it purges gasoline in the carburetor. If the engine fails when switching fuel sources simply restart the unit on the fuel source that you switched to. |
Figure 8 - Breakers
|
During normal operation, use the following steps to stop your generator:
If there is an emergency and the generator must be stopped quickly, position the engine control switch to the STOP position immediately.
BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION, AS WELL AS THE FOLLOWING SAFETY MESSAGES.
Avoid accidentally starting the generator during maintenance by removing the spark plug boot from the spark plug. For electric start generators, also disconnect the battery cables from the battery (disconnect the black negative (-) cable first) and place the cables away from the battery posts to avoid arcing. |
Allow hot components to cool to the touch prior to performing any maintenance procedure. |
Internal pressure can build in the engine crankcase while the engine is running. Removing the oil fill plug/ dipstick while the engine is hot can cause extremely hot oil to spray out of the crankcase and can severely burn skin. Allow engine oil to cool for several minutes before removing the oil fill plug/dipstick. |
Always perform maintenance in a wellventilated area. Gasoline fuel and fuel vapors are extremely flammable and can ignite under certain conditions. |
Failure to perform periodic maintenance or not following maintenance procedures can cause the generator to malfunction and could result in death or serious injury. |
NOTICE |
Periodic maintenance intervals vary depending on generator operating conditions. Operating the generator under severe conditions, such as sustained high-load, high-temperature, or unusually wet or dusty environments, will require more frequent periodic maintenance. The intervals listed in the maintenance schedule should be treated only as a general guideline. |
Avoid skin contact with engine oil or gasoline. Prolonged skin contact with engine oil or gasoline can be harmful. Frequent and prolonged contact with engine oil may cause skin cancer. Take protective measures and wear protective clothing and equipment. Wash all exposed skin with soap and water. |
Following the maintenance schedule is important to keep the generator in good operating condition. The following is a summary of maintenance items by periodic maintenance intervals.
TABLE 1: MAINTENANCE SCHEDULE - OWNER PERFORMED
Maintenance Item | Before Every Use | After First 20 Hours or First Month of Use | After 50 Hours of Use or Every 6 Months | After 100 Hour of Use or Every 6 Months | After 300 Hours of Use or Every Year |
Engine Oil | Check Level | Change | Change | - | - |
Cooling Features | Check/Clean | - | - | - | - |
Air Filter | Check | - | Clean* | - | Replace |
Spark Plug | - | - | - | Check/Clean | Replace |
Spark Arrestor | - | - | - | Check/Clean | - |
*Service more frequently if operating in dry and dusty conditions
TABLE 2: MAINTENANCE SCHEDULE - AUTHORIZED WESTINGHOUSE SERVICE DEALER PERFORMED
Maintenance Item | Before Every Use | After First 20 Hours or First Month of Use | After 50 Hours of Use or Every 6 Months | After 100 Hour of Use or Every 6 Months | After 300 Hours of Use or Every Year |
Valve Clearance | - | - | - | - | Check/Adjust |
Fuel Filter | - | - | - | Check/Clean | - |
Idle Speed | - | - | - | - | Check/Adjust |
NOTICE |
Always maintain proper engine oil level. Failure to maintain proper engine oil level could result in severe damage to the engine and/or shorten the life of the engine. Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine. |
Engine oil level should be checked before every use.
NOTICE |
Never dispose of used engine oil by dumping the oil into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility. |
Never use gasoline or other flammable solvents to clean the air filter. Use only household detergent soap to clean the air filter. |
The air filter must be cleaned after every 50 hours of use or 3 months (frequency should be increased if generator is operated in a dusty environment).
NOTICE |
NEVER twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action. |
NOTICE |
Never dispose of soap cleaning solution used to clean the air filter by dumping the solution into a sewer, on the ground, or into ground water or waterways. Always be environmentally responsible. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility. |
The spark plug must be checked and cleaned after every 100 hours of use or 6 months and must be replaced after 300 hours of use or every year.
NOTICE |
Never apply any side load or move the spark plug laterally when removing the spark plug. Applying a side load or moving the spark plug laterally may crack and damage the spark plug boot. |
NOTICE |
Use only recommended spark plugs when servicing. The manufacturer is not responsible for engine damage when using spark plugs not recommended by the manufacturer. |
AC Delco: 4EXLS
Autolite: 52
Champion: N9YC
Bosch: W7DC
Torch: F7TC
Checking and adjusting valve lash must be done when the engine is cold. |
Intake Valve | Exhaust Valve | |
Valve Lash | 0.0035 ± 0.0043 in (0.09 ± 0.11 mm) | 0.0043 ± 0.0051 in (0.11 ± 0.13 mm) |
Bolt Torque | 8-12N.m | 8-12N.m |
To ensure the battery remains charged, the generator should be started every 2 to 3 months and run for a minimum of 15 minutes or a charger should be plugged into the generator and the generator should be charged overnight. Make sure the engine control switch is in the "RUN" position when charging. Plug the cord from the charger into the charging port on the generator. Plug the charger into a 110/120-volt AC outlet.
It is important to inspect and clean the generator before every use.
Make sure all engine air inlet and outlet ports are clean of any dirt and debris to ensure the engine does not run hot.
Use a damp rag and a brush to loosen and remove all dirt on or around the engine's cooling fins.
Make sure the cooling air inlets and exhaust ports of the alternator are free of any debris and ob- structions. Use a vacuum cleaner to remove dirt and debris stuck in the cooling air inlets and exhaust ports.
Use a damp rag to clean all remaining surfaces.
Never store a generator with fuel in the tank indoors or in a poorly ventilated area where the fumes can come in contact with an ignition source such as a:
|
NOTICE |
Gasoline stored for as little as 60 days can go bad, causing gum, varnish and corrosive buildup in fuel lines, fuel passages and the engine. This corrosive buildup restricts the flow of fuel, preventing an engine from starting after a prolonged storage period. |
Proper care should be taken to prepare the generator for any storage.
Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner's manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death. | ||
PROBLEM | POTENTIAL CAUSE | SOLUTION |
Engine is running, but no electrical output |
|
|
|
| |
|
| |
|
| |
|
| |
Engine run erratic; does not hold a steady RPM. |
|
|
|
| |
|
| |
Generator suddenly stops running. |
|
|
|
| |
|
| |
|
| |
Engine will not start or remain running while trying to start. |
|
|
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
|
| |
Frost on the propane tank or regulator |
|
|
|
| |
|
| |
Propane fuel smell |
|
|
|
| |
|
| |
Poor performance or engine stalling on propane |
|
|
|
| |
|
|
DISCLAIMERS:
All information, illustrations and specifications in this manual are based on the latest information available at the time of publishing. The illustrations used in this manual are intended as representative reference views only. Moreover, because of our continuous product improvement policy, we may modify information, illustrations and/or specifications to explain and/or exemplify a product, service or maintenance improvement. We reserve the right to make any change at any time without notice. Some images may vary depending upon which model is shown.
ALL RIGHTS RESERVED:
No part of this publication may be reproduced or used in any form by any means – graphic, electronic or mechanical, including photocopying, recording, taping or information storage and retrieval systems – without the written permission of MWE Investments LLC.
HAVE QUESTIONS?
DO NOT RETURN THIS PRODUCT TO THE STORE
Email us at service@wpowereq.com
or call 1-855-944-3571
Service Hotline: (855) 944-3571
777 Manor Park Drive
Columbus, OH 43228
™ & © 2016 Westinghouse Electric Corporation
© 2016 MWE Investments, LLC. All Rights Reserved.