Advertisement

If the camera doesn't have a shutter, how can I per form a
Current Session Reference?
The Miro C's do not have a shutter, but you can still perform a Current Session Reference
(CSR). Just make sure you cover the lens before clicking the CSR button.
What are the available signals for the C211?
Trigger (dedicated BNC); SDI (dedicated BNC); Strobe (Aux 1 default); Ready (Aux 2 default), and
many other signals and capabilities through programmable I/O. However, please note that the
C211 does NOT have IRIG In, only IRIG Out.
What is the worst case power draw of the cameras?
The cameras draw only 12W during operation.
BA SIC TROUBLESHOOTING
There are fixed black spots on the image, par ticularly at small
aper tures.
This is most likely caused by dust particles stuck on the sensor surface. The best way to check
is to remove the lens and look at the glass surface with a bright light source. Vision Research
recommends not to use canned air or cotton swabs to clean the sensor surface. It is safer
to use a manual bulb-style air blower and/or sensor cleaning brush for removing loose dust
particles.
Additional tips for cleaning sensors can be found in the maintenance section of this manual.
The live images look scrambled and the frame rate can't
be set.
If the image is non-responsive and scrambled, the camera may be set to an external sync
T R O U B L E S H O O T I N G
Chapter 6: Suppor t | 3 3