Hantek MSO5000D User Manual
Hantek MSO5000D User Manual

Hantek MSO5000D User Manual

Mixed storage oscilloscope
Table of Contents

Advertisement

Quick Links

MSO5000D
Mixed Storage Oscilloscope
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Hantek MSO5000D

  • Page 1 MSO5000D Mixed Storage Oscilloscope User Manual...
  • Page 2: Table Of Contents

    Terms on Product ........................2 Symbols on Product ......................... 2 Product Scrapping ........................2 Chapter 2 Overview ........................3 Brief Introduction to MSO5000D ....................3 Help System ..........................3 Chapter 3 Getting Started Guide ..................... 5 Installation ..........................5 3.1.1 Power Supply ........................
  • Page 3 Example 11: Measuring Data Propagation Delay ..............62 6.12 Example 12: Using Trigger to Measure Digital Signal ............63 Chapter 7 Troubleshooting ....................68 Problem Settlement ........................ 68 Chapter 8 Specifications ......................69 Technical Specifications ......................69 Accessories ..........................75 MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 4 General Care and Cleaning .................. 77 General Care .......................... 77 Cleaning ..........................77 Appendix A Harmful and Poisonous Substances or Elements ..........78 Appendix B Index ........................79 Appendix C GNU GENERALPUBLIC LICENSE Version 2, June 1991 ........81 MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 5: Copyright Declaration

    Our company has made every effort to ensure the accuracy of this document but does not guarantee the absence of errors. Moreover, our company assumes no responsibility in obtaining permission and authorization of any third party patent, copyright or product involved in relation to the use of this document. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 6: Chapter 1 Safety Tips

    Do not operate with suspected failures. If you suspect there is damage to this product, have it inspected by qualified service personnel. Assure good ventilation. Do not operate in wet/damp environments. Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 7: Safety Terms And Symbols

    To avoid them being released outside and to minimize the waste of natural resources, we suggest you reasonably call back this device to ensure proper recovery and recycling of most materials within it. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 8: Chapter 2 Overview

    7 inch lolor Table 2-1 MSO5000D main specification MSO5000D oscilloscope is with the bandwidth of 60MHz/100MHz/200MHz, and provides the real-time and equivalent sample rates respectively up to 1GSa/s and 25GSa/s. In addition, it has maximum 1M memory depth for better observation of the waveform details, and 7 inch color TFT LCD as well as WINDOWS-style interfaces and menus for easy operation.
  • Page 9 Turn the HELP SCROLL knob to highlight a help topic. Press the Show Topic option button to display the topic. NOTE: Press the Exit option button or any menu button to remove the Help text from the screen and return to displaying waveforms. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 10: Chapter 3 Getting Started Guide

    PROBE COMP connectors. There is a mark on the panel: Probe COMP ~5V@1KHz. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 11: Observe The Waveform

    Do not touch metallic portions of the probe head while it is connected to a voltage source. Connect the probe to the oscilloscope and connect the ground terminal to ground before you start any measurements. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 12: Use Of Probe Check Wizard

    3. If necessary, use a nonmetallic screwdriver to adjust the variable capacity of your probe until the shape of the waveform turns to be the same as the above figure. Repeat this step as necessary. See the figure below for the way of adjustment. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 13: Probe Attenuation Setting

    20 minutes until it has adequately warmed up. To compensate the signal path, disconnect any probes or cables from the front-panel input connectors. Then, push the UTILITY button, select the Do Self Cal option and follow the directions on the screen. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 14: Logic Analyzer Flat Input Cable

    Getting Started Guide 3.7 Logic Analyzer Flat Input Cable MSO5000D series has logic analyzer function, and its logic signal input port is shown as follows: The flat terminal connection cable is shown as below. 1.Digital Input Terminal The total of digital signal input terminals is 18, arraged as two rows, GND, D0-D7 and GND, D8-D15.
  • Page 15: Chapter 4 Main Feature Description

    Trigger Source: The trigger can be generated with multiple sources. The most common one is the input channel (alternative between CH1 and CH2). Whether the input signal is displayed or not, it can trigger normal operations. Also the trigger source can be any signal connected to an external MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 16 The TRIGGER LEVEL knob controls the trigger point is on which position of the edge. Trigger level can be adjusted vertically Rising Edge Falling Edge Trigger slope can be rising or falling MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 17: Data Acquisition

    To compare data, you may align a waveform over another. When you push the VOLTS/DIV button to change the vertical scale of a waveform, the waveform display will contract or expand vertically to the ground level. Horizontal Scale and Position: Pretrigger Information MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 18: Waveform Measurement

    The time cursor appear as a vertical broken line, measuring the horizontal parameters. When using cursors, please make sure to set the Source to the waveform that you want to measure on the screen. To use cursors, push the CURSOR button. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 19 As this measurement uses the waveform record points, it is more precise than the graticule and cursor measurements. Automatic measurements show the measurement results by readouts which are periodically updated with the new data acquired by the oscilloscope. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 20: Chapter 5 Basic Operation

    The figure below illustrates the front panel of the MSO5000D digital oscilloscope. MSO5000D Front Panel of 5.1 Display Area...
  • Page 21 11. Readout points out horizontal waveform position 12. Trigger Type: : Edge trigger on the rising edge. : Edge trigger on the falling edge. : Video trigger with line synchronization. : Video trigger with field synchronization. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 22: X-Y Format

    The readout near the upper right of the screen shows the current horizontal position in second. M represents ‘Main Time Base’, and W indicates ‘Window Time Base’. The oscilloscope also has an arrow icon at the top of the graticule to indicate the horizontal position. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 23 In the expanded window will display corresponding waveforms until it stops once reaching the rightmost side of the major scan window Single-window Mode MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 24 When the major window is selected, this knob provides the same functions as it provides in single-mode window. When the minor window is selected, turn this knob to scale the waveform whose magnification is up to 1000. Notes: MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 25: Scan Mode Display (Roll Mode)

    Settings Comments DC passes both DC and AC components of the input signal. Coupling AC blocks the DC component of the input signal and Ground attenuates signals below 10Hz. Ground disconnects the input signal. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 26 Three types of window available for selection: Hanning, Flattop, Rectangular. CH1 or CH2 Zoom: Use the FFT Zoom button to adjust the window size. Scale: x1, x2, x5, x10. Note: All selected menus are highlighted in orange. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 27: Math Fft

    If you turn the SEC/DIV knob to select a faster setting (fewer cycles), the FFT spectrum will display a larger frequency range and reduce the possibility of FFT aliasing. To set the FFT display, follow the steps below. 1. Push the MATH MENU button; MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 28: Displaying Fft Spectrum

    Select a type of the FFT window. For more Window Rectangular information, refer to Section 5.3.1.3. Change the horizontal magnification of the FFT FFT Zoom X1, X2, X5, X10 display. For detailed information, refer to Section 5.3.1.6. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 29: Selecting Fft Window

    If the number of cycles is nonintegral, the YT waveform starts and ends at different amplitudes and transitions between the start and end points will cause discontinuities in the signal that introduces high-frequency transients. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 30 Better frequency, poorer amplitude accuracy than Flattop Flattop Periodic Waveform Better amplitude, poorer frequency accuracy than Hanning Pulse or Transient Special-purpose window applicable to discontinuous Rectangular Waveform waveforms. This is actually the same as no windows. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 31: Fft Aliasing

    When the FFT spectrum is being displayed, the channel vertical knobs become the zoom and position controls corresponding to their respective channels. The VOLTS/DIV knob provides the following zoom factors: X1(default), X2, X5 and X10. The FFT spectrum is magnified vertically to MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 32: Using Cursors To Measure Fft Spectrum

    The trigger can be defined through the Trigger Menu and front-panel controls. There are six types of trigger: Edge, Video, Pulse Width, Swap, Slope and Overtime. Refer to the following tables to find a different set of options for each type of trigger. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 33 It is used to complete an acquisition regardless of an adequate trigger signal. This button becomes useless if the acquisition is already stopped. 4. TRIG MENU Push this button to display trigger menus. The edge trigger is in common use. See the table below for details. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 34 Number for the Sync option, you may use the User Even Field Select knob to specify a line number. All Fields NTSC Choose a video standard for sync and line number Standard PAL/SECAM count. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 35 ±5% equal to width setting ±5% Threshold level Tolerance Tolerance = Trigger Point =, ≠: Within a ± 5% tolerance, triggers the oscilloscope when the signal pulse width is equal to MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 36 Below list options in submenus. Swap Trigger allows CH1 and CH2 to select different trigger modes and to display waveforms on a same screen. That is, both channels can choose the following four trigger modes. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 37 HF Reject LF Reject Next Page Adjust the vertical window by setting two trigger levels. Vertical Select this option and press F3 to choose V1 or V2. When Select the trigger condition. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 38: Menu And Option Buttons

    Acquisition Interval Acquisition Interval Trigger Level Indicates Trigger Points Holdoff Holdoff 5.5 Menu and Option Buttons As shown below, these six buttons at the top of the front panel are used mainly to recall relative MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 39: Save/Recall

    Save Complete the saving operation. Recall the oscilloscope settings stored in the location selected in the Operation Recall Setup field. Push the Default Setup button to initialize the oscilloscope to a known setup. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 40: Measure

    Measure the time between the first falling edge and the next Negative Width rising edge at the waveform 50% level. Do not take any measurement. Use the knob V0 or the functional keys F3, F4 to select the type of measurement. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 41: Acquire

    Normal: For the oscilloscope model with the bandwidth of 100MHz, the maximum sample rate is 1GS/s. For time base with insufficient sample rate, you may use the Sine Interpolation Algorithm to interpolate points between sampled points to produce a complete waveform record (4K by MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 42 Second Acquisition Third Acquisition Fourth Acquisition As shown above, acquire input signals (cycle repeatable) for more than once at a slow sample rate, arrange the sample points by the time they appear, then recover waveforms. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 43: Utility

    REFB S indicates Cursor 1. E indicates Cursor 2. Select Cursor A selected cursor is highlighted, which can be moved freely. Both cursors can be selected and moved at the same time. The box MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 44: Display

    For detailed information, refer to descriptions on XY format in the following text. 0-15 16 ranks adjustable, with a progress bar to Contrast display; Press F5 to select this option. Turn the multi-functional knob to adjust. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 45: Fast Action Buttons

    Trigger Holdoff Minimum Trigger Level Set to 50% Trigger Mode Auto Trigger Source Adjusted; Autoset can not be used for the EXT TRIG signal Trigger Slope Adjusted Trigger Type Edge Trigger Video Sync Adjusted MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 46: Help

    5.6.2 Help Push the HELP button to display the Help menu which provides topics covering all the menu options and controls of the oscilloscope. For detailed information about the Help system, refer to Section 2.2. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 47: Default Setup

    Type None Type Edge Source Slope Rising Trigger (Edge) Mode Auto Coupling Level 0.00v Polarity Normal Sync All lines Trigger (Video) Standard NTSC When Set Pulse Width 1.00ms Trigger (Pulse) Polarity Positive Mode Auto MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 48 Position 0.00div (0.00V) VOLTS/DIV 1.00V The following settings do not change when you push the DEFAULT SETUP button.  Language Option  Saved Settings  Saved Reference Waveforms  Display Contrast  Calibration Data MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 49: Multi-Functional Knobs And Buttons

    2. EXT TRIG: Input connector for an external trigger source, though with to connect and input the external trigger signal. 3. Probe Compensation: Voltage probe compensation output and ground, used to electrically match the probe to the oscilloscope input circuit. The probe compensation ground and BNC MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 50: Logic Analyzer Channels Setup

    5.9 Logic Analyzer Channels Setup MSO5000D series- the mixed signal oscilloscope equipped with 16 channels logical analyzer, which provides 16 logical channels, is able to carry out the measurement on mixed signals with the other 2 analog oscilloscope channels.
  • Page 51 Press F7-> F7->D7-D0 or D15-D8, the system will display D7-D0 or D15-D8 channel group setup menu, open or close a single channel or a group channel ( with 8 channels for a group) and setup MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 52 Press F7-> F7->D7-D0->waveform size, or push D15-D8->waveform size to select the size of the digital channel waveforms. 4. Reset the display of the digital channel waveforms Press F7-> F7->D7-D0->reset, or push D15-D8->reset to make the digital channel display reset. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 53: Chapter 6 Application Examples

    The oscilloscope will automatically set the waveform to a best display. If you want to further optimize the waveform display, you may manually adjust the vertical and horizontal controls until the waveform meets your particular requirement. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 54 Repeat Step 2 and Step 3. Then select other measure items. Totally 8 measure items can be displayed. Note: All readouts change with the measured signals. The figure below shows three measure items as an example. The boxes under them display the measurements in large fonts. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 55: Example 2: Taking Cursor Measurements

    Put Cursor S on the highest peak of the ring. 10. Put Cursor E on the lowest point of the ring. The amplitude of the ring will be displayed at Delta. See figures below for better understanding. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 56 Place Cursor S on the rising edge of the pulse and Cursor E on the falling edge. Thus at Delta displays the measured time and at Cursor S and Cursor E displays the time relative to the trigger. See the figure below for better understanding. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 57 Select Cursor E and turn V0 to place it at the 90% level of the waveform. 10. The Delta readout in the Cursor Menu is the rise time of the pulse. See the figure below for better understanding. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 58: Example 3: Analyzing Input Signals To Eliminate Random Noise

    Push the Type option button and select Real Time. Push the Peak Detect option button. If necessary, push the DISPLAY button and set the Contrast option to view the noise more clearly. See the figure below for better understanding. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 59: Example 4: Capturing Single-Shot Signal

    Note: Averaging reduces random noise and let you view the signal details more easily. See the figure below for better understanding 6.4 Example 4: Capturing Single-shot Signal You may refer to the following example to easily capture some aperiodic signals like pulses and glitches. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 60: Example 5: Using X-Y Mode

    Push the CH1 MENU button and set the Probe option attenuation to 10X; push the CH2 MENU button and set the Probe option attenuation to 10X. Connect the CH1 probe to the input of the network, and connect the CH2 probe to the output. Push the AUTOSET button. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 61: Example 6: Triggering On Pulse Width

    Or even if the edge triggering shows that your signal has the same pulse width with the specific signal, you still doubt about the result. Then you can follow the MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 62: Example 7: Triggering On Video Signal

    Assume that you are monitoring the video signals of a television to see if they are input normally, and the video signal is of an NTSC system. You can get a stable display by using the video trigger. Triggering on Video Fields MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 63 Turn V0 to adjust the line number (NTSC: 0-525 lines). Turn the horizontal SEC/DIV and the vertical VOLTS/DIV knobs to display on the screen a complete video signal triggering on a video line. See the figure below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 64: Example 8: Using Slope Trigger To Capture Particular Slope Signal

    Click the ‘Next Page’ button and select Vertical. Turn the V0 knob to adjust V1 and V2 to proper locations. Select the When option button and set it to ‘=’. Select ‘Time’ and turn V0 to adjust the time until you get a stable display of waveforms. See the figure below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 65: Example 9: Using Overtime Trigger To Measure Long Pulse Signal

    Turn V0 to adjust the line number (NTSC: 0-525 lines). Turn the horizontal SEC/DIV and the vertical VOLTS/DIV knobs to display on the screen a complete video signal triggering on a video line. See the figure below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 66: Example 10: Using Math Functions To Analyze Waveforms

    Note: You should compensate both probes before performing the math operation; otherwise, differences in probe compensation will appear as errors in the differential signal. As illustrated in the above figure, input a 1KHz sine wave from CH1 and a 1KHz square wave from MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 67: Example 11: Measuring Data Propagation Delay

    Select Cursor S and turn V0 to place it on the active edge of the enable signal. Select Cursor E and turn V0 to place it on the data output transition (See the figure below). 10. Read the data propagation delay in the Delta readout. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 68: Example 12: Using Trigger To Measure Digital Signal

    5. Push F4 button to select the trigger mode : Auto or Normal 6. The coupling method is only applicable to the analog signal. 7. Turn the timebase knob “SEC/DIV” and adjust the time until you get a stable display of MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 69 8. Push F5 button to select the the pulse width of the trigger, and turn VO knob to adjust the trigger pulse width. 9. Turn the timebase knob “SEC/DIV“ and adjust the time until you get a stable display of waveforms. See the picture below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 70 6. Turn the timebase knob “SEC/DIV“ and adjust the time until you get a stable display of waveforms. See the picture below. Duration Trigger. To observe digital signal by using the duration trigger, please follow the steps as below: 1.Push the TRIG MENU button to see the trigger menu. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 71 5. 5.Push F4 button to select the pattern ( H, L or X). 6. Turn the timebase knob “SEC/DIV” and adjust the time until you get a stable display of waveforms. See the picture below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 72 5. Push F4 button to select the “Times” of Iteration, and turn VO knob to set the times. 6. Turn the timebase knob “SEC/DIV” and adjust the time until you get a stable display of waveforms. See the picture below. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 73: Chapter 7 Troubleshooting

    3) Check the trigger mode to confirm it is a right choice for the input signal. The default trigger mode is edge trigger. However, it is not suitable for all kinds of input signals. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 74: Chapter 8 Specifications

    20ns/div to 80μs/div Position Range (-8div × s/div) to 40ms 200μs/div to 40s/div (-8div × s/div) to 400s Vertical 8-bit resolution, A/D Converter each channel sampled simultaneously VOLTS/DIV Range 2mV/div to 10V/div at input BNC MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 75 Attenuates signals above 80kHz Same as the DC-coupled limits for frequencies above LF Reject 150kHz; attenuates signals below 150kHz Source Range Trigger Level Range CH1, CH2 ± 8 divisions from center of screen ± 1.2V MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 76 Slope Trigger Point Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 77 16, 32, 64 or 128 Inputs Inputs Input Coupling DC, AC or GND Input Impedance, 1MΩ±2% in parallel with 20pF± 3pF DC coupled Probe Attenuation 1X, 10X Supported Probe 1X, 10X, 100X, 1000X Attenuation Factors MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 78 +104℉ or below (+40℃ or below): ≤90% relative humidity Humidity 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity Altitude Operating and Nonoperating 3,000m (10,000 feet) 0.31g from 50Hz to 500Hz, 10 Random Vibration minutes on each axis MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 79 D0-D15 Code Type (H,L,X) Trigger D0-D15 Continuous Time and Trigger Event (Data Finish, Continuous Data Begin, Data Delay) Array D0-D15 Data Index (0-3) and Code Type (H,L,X) Repeat D0-D1 Code Type (H,L,X), Repeat Times MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 80: Accessories

    PC and the oscilloscope. 16 channel cable for logic analyzer A software installation CD. It contains the user manual of MSO5000D, giving particular descriptions on the MSO5000D series oscilloscopes. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 81: Open Source Information

    IO-bank Driver, USB Host Driver, LCD Driver, USB massstorage、gadget Driver Linux Applications busybox1.18.4, gnupg1.4.11 U_boot Version U_boot 1.1.6 Sourcecode download website http://www.produktinfo.conrad.com (Please enter the product code "122485" to search) License: GPLV2 See Appendix C MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 82: Chapter 9 General Care And Cleaning

    2) Use a soft cloth dampened with water to clean the oscilloscope. For more efficient cleaning, you may use an aqueous solution of 75% isopropyl alcohol. Note: To avoid damage to the surface of the oscilloscope or probes, do not use any corrosive or chemical cleaning agents. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 83: Appendix A Harmful And Poisonous Substances Or Elements

    ‘0’ indicates that the content of this poisonous and harmful substance in all homogeneous materials of this component is refrained under the limit stated in the SJ/T 11363-2006 standard. This component list contains components approved in the file ‘Management Measures’. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 84: Appendix B Index

    DISPLAY button Main time base Dual-window Math FFT MATH MENU button MEASURE button Edge trigger Measure FFT spectrum EXT TRIG Measurement cursor Mechanical Factory setup Mechanical shock FFT aliasing Menu hiding FFT Window Multi-functional knob MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 85 Window Time Base Scan mode display (roll mode) 19 SECAM SEC/DIV knob XY format Self calibration SET TO 50% button Simple measurement Sine wave SINGLE SEQ button Slope Slope trigger Software installation CD Square wave MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 86: Appendix C Gnu Generalpublic License Version 2, June 1991

    If the software is modified by someone else and passed on, we want its recipients to know that what they have is not the original, so that any problems introduced by others will not reflect on the original authors' reputations. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 87 You must cause any work that you distribute or publish, that in whole or in part contains or is derived from the Program or any part thereof, to be licensed as a whole at no charge to all third parties under the terms of this License. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 88 The source code for a work means the preferred form of the work for making modifications to it. For an executable work, complete source code means all the source code for all modules it MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 89 If any portion of this section is held invalid or unenforceable under any particular circumstance, the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 90 EITHER EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU. MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 91 02110-1301 USA. Also add information on how to contact you by electronic and paper mail. If the program is interactive, make it output a short notice like this when it starts in an interactive mode: MSO5000D Digital Storage Oscilloscope User Manual...
  • Page 92 If your program is a subroutine library, you may consider it more useful to permit linking proprietary applications with the library. If this is what you want to do, use the GNU Lesser General Public License instead of this License. MSO5000D Digital Storage Oscilloscope User Manual...

Table of Contents