Compex SGX3226 User Manual page 86

24+2 gigabit snmp switch with integrated router
Hide thumbs Also See for SGX3226:
Table of Contents

Advertisement

Appendix I
Panel Views and Descriptions
Features
5
Redundant Power
Socket
6
Reset Button
7
Mute Button
8
System Status LEDs
9
Power LED
10
Redundant PS LED
Status and Indication
Additional Power Socket (Optional). With this RPS,
Compex SGX3226 still able to operate even Primary Power
Supply is down.
By pushing the reset button once,
The switch will clear all previous temporary error
P.O.S.T. will activate self-diagnostic program to check
any error.
Switch would be re-configured with settings stored in
non-volatile flash memory.
To toggle the On or Off Switch of the Alarm Buzzer
Steady Green
Normal Operation
Steady Red
POST is running Self-diagnostic after reset
or power up
Steady Green
Power supply is working in normal
condition.
Steady Red
Power supply is faulty.
Power supply fault occurs.
Steady Green
Primary power supply is working and RPS
is in standby mode.
Steady Red
Primary power supply is faulty and RPS is
in working condition.
When the primary power resume its
electrical supply, RPS LED will still
remains Steady Red unless you reboot
your switch, then RPS LED will turn to
Steady Green.
Off
Both primary power supply and RPS
turned off.