[Data]

16. Abnormal state (Command: z)

Abnormal State: Used to Read the power off status when Stand-by mode.
Transmission
[k][z][][Set ID][][Data][Cr]
[Data]
Acknowledgement
[z][][Set ID][][OK][Data][x]
[Data]

17. ISM Method (Command: j p)

Used to select the afterimage preventing function.
Transmission
[j][p][][Set ID][][Data][Cr]
[Data]
ENWW
0: Medium
1: Cool
2: Warm
FF: Read
0: Normal (Power on and signal exist)
1: No signal (Power on)
2: Turn the display off by remote control
3: Turn the display off by sleep time function
4: Turn the display off by RS-232-C function
8: Turn the display off by off time function
9: Turn the display off by auto off function
1H: Inversion
2H: Orbiter
4H: White Wash
8H: Normal