M-system R7HL-DC8C-R Instruction Manual

Relay contact output module, 8 points (high-speed link system)

Advertisement

Quick Links

INSTRUCTION MANUAL
RELAY CONTACT OUTPUT MODULE, 8 points
(High-speed Link System)
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete output module.......................................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVE
• This equipment is suitable for Pollution Degree 2 and
Measurement Category II (output, transition voltage
1500V) with the maximum operating voltage 125V.*
sic insulation (output to power: 150V)*
Prior to installation, check that the insulation class of
this unit satisfies the system requirements.
*1. For use in Measurement Category I (output, transition
voltage 1500V) with the maximum operating voltage 250V.
*2. For use in Measurement Category I, 300V.
• Altitude up to 2000 meters.
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• Use dual-shield cables (Shinko Seisen Industry Model
ZHY262 PBA) for the network. If it is not sufficient, use
a ferrite core (Kitagawa Industries Model GRFC-13) for
the network cable.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 45mA
SEN TRONIC
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
Ba-
• The unit is designed to function as soon as power is sup-
1
is maintained.
2
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
056 222 38 18
mailbox@sentronic.com
AG
R7HL-DC8C
MODEL
EM-7812-U Rev.5 P. 1 / 5
www.sentronic.com

Advertisement

loading

Summary of Contents for M-system R7HL-DC8C-R

  • Page 1 • Before you remove the unit or mount it, turn off the power supply and output signal for safety. Thank you for choosing M-System. Before use, please check • DO NOT set the switches on the module while the power contents of the package you received as outlined below.
  • Page 2: Component Identification

    R7HL-DC8C COMPONENT IDENTIFICATION SIDE VIEW FRONT VIEW Operating Mode Setting DIP SW (SW1) Station Address Setting Rotary SW Discrete Output Status Indicator LED Status Indicator LED STATION ADD. 10 11 12 13 15 16 17 18 Network, Power Supply Output Terminal Terminating Resistor SW Terminals ■...
  • Page 3: Terminal Connections

    R7HL-DC8C ■ OUTPUT TERMINAL ASSIGNMENT +24V COM0 COM0 COM0 COM0 COM1 COM1 COM1 COM1 FUNCTION FUNCTION +24V 24V DC COM0 Common 0 Output 0 COM0 Common 0 Output 1 COM0 Common 0 Output 2 COM0 Common 0 Output 3 COM1 Common 1 Output 4 COM1...
  • Page 4: Wiring Instructions

    R7HL-DC8C ■ CONNECTION DIAGRAM Output Connection Example RXD+ (TR+) 4 points / common 8 points / common 24V DC 24V DC RXD– (TR–) – – + 24V + 24V TXD + (NC) TXD– (NC) COM0 24V DC COM0 COM0 COM0 –...
  • Page 5: Communication Cable Connections

    R7HL-DC8C COMMUNICATION CABLE CONNECTIONS MASTER CONNECTION • Full-duplex communication Master Module Slave Module Slave Module TXD + RXD + RXD + TXD – RXD – RXD – Terminating Terminating RXD + TXD + TXD + Resistor Resistor RXD – TXD – TXD –...