Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Discrete output module.......................................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ CONFORMITY WITH EU DIRECTIVE
• This equipment is suitable for Pollution Degree 2 and
Measurement Category II (output, transition voltage
1500V) with the maximum operating voltage 125V.*
sic insulation (output to power: 150V)*
Prior to installation, check that the insulation class of
this unit satisfies the system requirements.
*1. For use in Measurement Category I (output, transition
voltage 1500V) with the maximum operating voltage 250V.
*2. For use in Measurement Category I, 300V.
• Altitude up to 2000 meters.
• The equipment must be mounted inside the instrument
panel of a metal enclosure.
• Use dual-shield cables (Shinko Seisen Industry Model
ZHY262 PBA) for the network. If it is not sufficient, use
a ferrite core (Kitagawa Industries Model GRFC-13) for
the network cable.
• The equipment must be installed such that appropriate
clearance and creepage distances are maintained to con-
form to CE requirements. Failure to observe these re-
quirements may invalidate the CE conformance.
• The actual installation environments such as panel con-
figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated
in a panel system. The user may have to review the CE
requirements in regard to the whole system and employ
additional protective measures to ensure the CE conform-
ity.
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V DC rating: 24V ±10%, approx. 45mA
Ba-
1
is maintained.
2
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
MODEL
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
• DO NOT set the switches on the module while the power
is supplied. The switches are used only for maintenance
without the power.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
R7HL-DC8C
EM-7812-U Rev.5 P. 1 / 5

Advertisement

loading

Summary of Contents for M-system R7HL-DC8C

  • Page 1 • Before you remove the unit or mount it, turn off the power supply and output signal for safety. Thank you for choosing M-System. Before use, please check • DO NOT set the switches on the module while the power contents of the package you received as outlined below.
  • Page 2: Component Identification

    Power input (24V DC) 12 Mbps (*) Power input (0V) 6 Mbps Note: Be sure to set unused SW1-1 through 1-6 to OFF. EM-7812-U Rev.5 P. 2 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 3: Terminal Connections

    15 16 17 18 30 (1.18) [5 (.20)] 6 (.24) 6 (.24) 18–M3 SCREW 7–M3 SCREW TERMINALS TERMINALS for OUTPUT for Network, POWER EM-7812-U Rev.5 P. 3 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 4: Wiring Instructions

    Recommended manufacturer: Japan Solderless Terminal MFG. Co., Ltd. or Nichifu Co., Ltd. 3.3 (.13) max 4 (.16) min 3.2 (.13) dia. mm (inch) EM-7812-U Rev.5 P. 4 / 5 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp...
  • Page 5: Communication Cable Connections