2. FUNCTION SETTINGS
Upper shaft control settings
Setting
No.
range
Needle up stop when operation is paused
150
OFF
ON
Upper shaft speed correction (rpm)
151
-30 - 30
Upper shaft final stitch speed (rpm)
152
700 - 900
Upper shaft speed immediately before stopping (rpm)
153
250 - 450
Current limit value during upper shaft acceleration
154
1 - 8
Current limit value during upper shaft deceleration
155
1 - 8
Upper shaft stopping distance (°)
156
2.5 - 17.5
Brake release speed when upper shaft stops
157
1 - 5
NOTE:
Do not change the settings for Nos. 151 - 157 unless specifically instructed to by the manufacturer.
7
Upper shaft stops immediately when sewing is paused.
Upper shaft stops at needle up stop position when sewing is paused.
Correction can be carried out with respect to the setting speed.
Setting can be carried out in units of 10 rpm.
The speed for the final stitch can be set.
Setting can be carried out in units of 10 rpm.
The speed immediately before stopping can be set.
Setting can be carried out in units of 10 rpm.
When a larger value is set, a larger amount of current flows during acceleration.
When a larger value is set, a larger amount of current flows during deceleration.
When a larger value is set, the interval for stopping control becomes longer.
Setting can be carried out in units of 0.5°.
When a larger value is set, the brake is released more quickly.
Setting items
RH-9820
Default
value
ON
0
800
350
8
1
11
3