Table 15. LCD Message Troubleshooting Table (continued)
HMR BANK FAN FLT
Yes
HB NOT INSTALLD*
No
ILL EXT BUS ACC*
No
ILLGL OPR ACCSS*
No
ILL INST ACCSS*
No
INTAKE FAN FAULT
Yes
LO DRV. SHORT *
No
LOAD PAPER
Yes
ONLINE
No
8344 FAILED*
PAP BAD TABLE*
No
PAP BSY TOO LNG*
No
PAP FIFO OVERFL*
No
PAP FIFO UNDRFL*
No
Sensors cannot detect
current in fan circuit.
Self-test does not detect
hammer coils.
Fatal firmware error on
controller board.
Fatal firmware error on
controller board.
Fatal firmware error on
controller board.
Sensors cannot detect
current in fan circuit.
Circuit(s) on the hammer
bank or in the hammer bank
power cable shorted to
ground.
Printer is out of paper.
Link-level code test detects
hardware failure.
Fatal firmware error on
controller board.
Fatal firmware error on
controller board.
Fatal firmware error on
controller board.
Fatal firmware error on
controller board.
Fault Messages
Check that fan cable is
connected. Check for obstruction
of vents and fan airway; remove
any obstructions. Check for items
beneath the printer blocking
cabinet vents. Power back on the
printer. If this message recurs,
contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
See description for
HMR BANK FAN FLT.
Contact your authorized service
1
representative.
Load paper.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
Contact authorized service
1
representative.
Contact your authorized service
1
representative.
Contact your authorized service
1
representative.
203