Table of Content 1. Introduction ............................2 2. Appearance ............................3 3. Main Features ........................... 3 4. Set up Instruction ..........................4 5. Data Report ............................5 6. Installation ............................9 7. Important Maintenance Instruction ....................10...
1. Introduction R718DB is identified as a LoRaWAN ClassA device with a spring-loaded vibration sensor and compatible with LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
Low power consumption and long battery life Note: Battery life is determined by the sensor reporting frequency and other variables . Please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find various types of battery life time in different configurations.
4.Set up Instruction On/Off Power on Insert batteries (Users may need a screwdriver to open) Turn on Press and hold the function key for 3 seconds and the green indicator flash once. Turn off (Restore to factory setting) Press and hold the function key for 5 seconds and the green indicator flashes 20 times. Power off Remove Batteries.
The device report interval will be programmed based on the default firmware which may vary. The interval between two reports must be the minimum time. Please refer Netvox LoRaWAN Application Command document and Netvox Lora Command Resolver http://loraresolver.netvoxcloud.com:8888/page/index to resolve uplink data.
Page 8
0x00_DO NOT report when sensor restore ReportReq (8Bytes,Fixed 0x00) 0x01_DO report when sensor restore SetRestore Status Reserved 0x83 ReportRsp (0x00_success) (8Bytes, Fixed 0x00) R718DB 0x1B GetRestore Reserved 0x04 ReportReq (9Bytes, Fixed 0x00) RestoreReportSet (1byte) Reserved GetRestore 0x84 0x00_DO NOT report when sensor restore...
Page 9
Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping(MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data REPORT 3.6V...
6. Installation 1. The device has a built-in magnet. 3.The figure shows the vibration sensor (R718DB) When installed, it can be attached to the surface of an applied to the scene of the mousetrap in the restaurant. object with iron which is convenient and quick.
7. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid, might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.